Incorporation of wavelet-based denoising in iterative deconvolution for partial volume correction in whole-body PET imaging

被引:98
|
作者
Boussion, N. [1 ]
Le Rest, C. Cheze [1 ]
Hatt, M. [1 ]
Visvikis, D. [1 ]
机构
[1] CHU MORVAN, INSERM, U650, LaTIM, F-29609 Brest, France
关键词
FDG-PET; Image processing; Partial volume correction; Whole-body PET; MATTER VOLUME; DECOMPOSITION; VALIDATION; ALGORITHMS;
D O I
10.1007/s00259-009-1065-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Partial volume effects (PVEs) are consequences of the limited resolution of emission tomography. The aim of the present study was to compare two new voxel-wise PVE correction algorithms based on deconvolution and wavelet-based denoising. Deconvolution was performed using the Lucy-Richardson and the Van-Cittert algorithms. Both of these methods were tested using simulated and real FDG PET images. Wavelet-based denoising was incorporated into the process in order to eliminate the noise observed in classical deconvolution methods. Both deconvolution approaches led to significant intensity recovery, but the Van-Cittert algorithm provided images of inferior qualitative appearance. Furthermore, this method added massive levels of noise, even with the associated use of wavelet-denoising. On the other hand, the Lucy-Richardson algorithm combined with the same denoising process gave the best compromise between intensity recovery, noise attenuation and qualitative aspect of the images. The appropriate combination of deconvolution and wavelet-based denoising is an efficient method for reducing PVEs in emission tomography.
引用
收藏
页码:1064 / 1075
页数:12
相关论文
共 50 条
  • [31] MR-based Attenuation Correction for Whole-body PET/MR System
    Hu, Z.
    Renisch, S.
    Schweizer, B.
    Blaffert, T.
    Ojha, N.
    Guo, T.
    Tang, J.
    Tung, C.
    Kaste, J.
    Schulz, V.
    Torres, I.
    Shao, L.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2119 - 2122
  • [32] A novel partial volume effects correction technique integrating deconvolution associated with denoising within the PET image reconstruction process
    Merlin, T.
    Le Pogam, A.
    Fernandez, P.
    Visvikis, D.
    Lamare, F.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2429 - 2432
  • [33] MR-based attenuation correction for whole-body PET-MR
    Ouyang, Jinsong
    Chun, Se Young
    Brady, Thomas
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [34] MR-based attenuation correction for whole-body PET-MR
    Ouyang, Jinsong
    Chun, Se Young
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [35] Attenuation correction for whole-body PET imaging using automated fuzzy clustering-based segmentation method
    Zaidi, H
    Diaz-Gomez, M
    Boudraa, A
    Slosman, DO
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2100 - 2104
  • [36] EVALUATION OF A LITERATIVE DENOISING/DECONVOLUTION METHOD TO QUANTIFY WHOLE-BODY GLUCOSE METABOLISM BY 18F-FDG PET IN MICE
    Safavi-Naeini, M.
    Franklin, D.
    Aurthur, A.
    Zahra, D.
    Parmar, A.
    Reilhac, A.
    Wimberley, C.
    Charil, A.
    Gregoire, M.
    INTERNAL MEDICINE JOURNAL, 2016, 46 : 18 - 18
  • [37] Deconvolution-based partial volume correction of PET images with parallel level set regularization
    Zhu, Yansong
    Bilgel, Murat
    Gao, Yuanyuan
    Rousset, Olivier G.
    Resnick, Susan M.
    Wong, Dean F.
    Rahmim, Arman
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (14):
  • [38] POST INJECTION TRANSMISSION FOR WHOLE-BODY FDG PET CANCER STUDIES IN A VOLUME IMAGING SCANNER
    SMITH, RJ
    YAN, M
    KARP, JS
    COUNTRYMAN, PJ
    MUEHLLEHNER, G
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P188 - P188
  • [39] Low-Noise Correction of Partial Volume Effect in whole body FDG-PET
    Korkola, P.
    Tohka, J.
    Koskinen, M. O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S312 - S312
  • [40] Evaluation of MR imaging-based partial volume correction methods for PET imaging
    Meltzer, CC
    Kinahan, P
    Greer, PJ
    Nichols, TE
    Price, JC
    RADIOLOGY, 1997, 205 : 1261 - 1261