Reverse Interlocking Protection using IEC 61850 GOOSE

被引:0
|
作者
Daboul, Mayada [1 ]
Orsagova, Jaroslava [1 ]
机构
[1] Fac Elect Engn & Commun, Dept Elect Power Engn, Brno, Czech Republic
关键词
IEC; 61850; GOOSE; bus-bar protection;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Protection and Automation systems have been significantly developed as a result of advanced Intelligent Electronic Devices (IEDs) which are adapted to work with various communication interfaces. International standard IEC 61850 has facilitated high-speed peer-to-pee communications among IEDs by replacing analogue and binary signals by Ethernet messages so it reduces the cost of the system and improves the flexibility and the functionality of the system. This paper shows how to use the IEC 61850 within protection schemes which should be developed after assistance by communications system based on the new standard. The paper focuses on one type of protection schemes (Reverse Interlocking) that can be implemented using Generic Object-Oriented Substation Event (GOOSE) messages. A laboratory set-up including the software and hardware presented. Regarding to the terms of feasibility, speed, and dependability, laboratory results are discussed at the end.
引用
收藏
页码:665 / 669
页数:5
相关论文
共 50 条
  • [21] GOOSE performance assessment on an IEC 61850 redundant network
    Essa, Mohamed Hosny Tawfeek
    Crossley, Peter
    JOURNAL OF ENGINEERING-JOE, 2018, (15): : 841 - 845
  • [22] Transformer Load Tap Changer Control Using IEC 61850 GOOSE Messaging
    Sichwart, Nelli
    Eltom, Ahmed
    Kobet, Gary
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [23] Modeling of IEC 61850 GOOSE Substation Communication Traffic Using ARMA Model
    Feizimirkhani, Ronak
    Bratcu, Antoneta Iuliana
    Besanger, Yvon
    Labonne, Antoine
    Braconnier, Thierry
    PROCEEDINGS OF 2019 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT-EUROPE), 2019,
  • [24] A study on GOOSE communication based on IEC 61850 using MMS Ease Lite
    Nguyen-Dinh, Nhat
    Kim, Gwan-Su
    Lee, Hong-Hee
    2007 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS, VOLS 1-6, 2007, : 715 - 719
  • [25] Implementation of Automatic Bus Transfer Scheme Using Multifunction Numerical Protection Relay IEDs on IEC 61850 GOOSE Messaging
    Sahoo, Binaya Kumar
    Mehtani, Moksh
    2018 4TH INTERNATIONAL CONFERENCE FOR CONVERGENCE IN TECHNOLOGY (I2CT), 2018,
  • [26] Applications and advantages for protection schemes using IEC 61850 standard
    Duncan, Brent
    Self, Howard
    2006 Power Systems Conference Advanced Metering, Protection, Control, Communication, and Distributed Resources, 2006, : 63 - 72
  • [27] Fault Location, Isolation, and Service Restoration (FLISR) Technique using IEC 61850 GOOSE
    Parikh, Palak
    Voloh, Ilia
    Mahony, Michael
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [28] Implementation of Protection and Control Systems in the Transmission SS 110/10(20)/10 kV Using IEC 61850 GOOSE Messages
    Cokic, Adnan
    Celjo, Admir
    ADVANCED TECHNOLOGIES, SYSTEMS, AND APPLICATIONS III, VOL 1, 2019, 59 : 243 - 254
  • [29] IEC 61850 GOOSE transfer time measurement in development stage
    Gonzalez-Redondo, Miguel J.
    Moreno-Munoz, Antonio
    Pallares-Lopez, Victor
    Real-Calvo, Rafael J.
    Ortiz Lopez, Manuel A.
    Moreno-Garcia, Isabel M.
    2013 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2013,
  • [30] A Method for Achieving Confidentiality and Integrity in IEC 61850 GOOSE Messages
    Hussain, S. M. Suhail
    Farooq, Shaik Mullapathi
    Ustun, Taha Selim
    IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (05) : 2565 - 2567