Automated tracking of muscle fascicle orientation in B-mode ultrasound images

被引:80
|
作者
Rana, Manku [1 ]
Hamarneh, Ghassan [2 ]
Wakeling, James M. [1 ]
机构
[1] Simon Fraser Univ, Sch Biomed Physiol & Kinesiol, Burnaby, BC V5A 1S6, Canada
[2] Simon Fraser Univ, Med Image Anal Lab, Sch Comp Sci, Burnaby, BC V5A 1S6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Muscle fascicle tracking; Segmentation; Functional imaging; VASTUS LATERALIS MUSCLE; IN-VIVO MEASUREMENTS; LENGTH CHANGES; JOINT ANGLE; ARCHITECTURE; TENDON; BEHAVIOR; FIBER; HETEROGENEITY; PENNATION;
D O I
10.1016/j.jbiomech.2009.06.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
B-mode ultrasound can be used to non-invasively image muscle fascicles during both static and dynamic contractions. Digitizing these muscle fascicles can be a timely and subjective process, and usually studies have used the images to determine the linear fascicle lengths. However, fascicle orientations can vary along each fascicle (curvature) and between fascicles. The purpose of this study was to develop and test two methods for automatically tracking fascicle orientation. images were initially filtered using a multiscale vessel enhancement (a technique used to enhance tube-like structures), and then fascicle orientations quantified using either the Radon transform or wavelet analysis. Tests on synthetic images showed that these methods could identify fascicular orientation with errors of less than 0.06 degrees. Manual digitization of muscle fascicles during a dynamic contraction resulted in a standard deviation of angle estimates of 1.41 degrees across ten researchers. The Radon transform predicted fascicle orientations that were not significantly different from the manually digitized values, whilst the wavelet analysis resulted in angles that were 1.35 degrees less, and reasons for these differences are discussed. The Radon transform can be used to identify the dominant fascicular orientation within an image, and thus used to estimate muscle fascicle lengths. The wavelet analysis additionally provides information on the local fascicle orientations and can be used to quantify fascicle curvatures and regional differences with fascicle orientation across an image. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2068 / 2073
页数:6
相关论文
共 50 条
  • [41] Automated liver tissue segmentation in point of care ultrasound b-mode images using U-Net
    Garcia, Raul Blazquez
    Lightstone, Adi
    Ibrahim, Miriam Naim
    El Kaffas, Ahmed
    CLINICAL CANCER RESEARCH, 2021, 27 (05)
  • [42] Quantized Local Edge Distribution: A Descriptor for B-mode Ultrasound Images
    Chan, Wing-Yin
    Chui, Yim-Pan
    Heng, Pheng-Ann
    AUGMENTED REALITY ENVIRONMENTS FOR MEDICAL IMAGING AND COMPUTER-ASSISTED INTERVENTIONS, 2013, 8090 : 192 - 200
  • [43] The measurement of low sediment concentration based on B-mode ultrasound images
    Ma, Zhimin
    Zou, Xianjian
    Zhao, Xiaohong
    Hu, Xiangyang
    Yingyong Jichu yu Gongcheng Kexue Xuebao/Journal of Basic Science and Engineering, 2013, 21 (04): : 796 - 803
  • [44] Current Trends in Segmentation of Medical Ultrasound B-mode Images: A Review
    Shrimali, Vibhakar
    Anand, R. S.
    Kumar, Vinod
    IETE TECHNICAL REVIEW, 2009, 26 (01) : 8 - 17
  • [45] Common Carotid Artery Wall Localization in B-mode Ultrasound Images for Initialization of Artery Wall Tracking Methods
    Dorazil, Jan
    Riha, Kamil
    Dutta, Malay Kishore
    2019 42ND INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2019, : 605 - 608
  • [46] A comparison of acute changes in muscle thickness between A-mode and B-mode ultrasound
    Kuehne, Tayla E.
    Yitzchaki, Noam
    Jessee, Matthew B.
    Graves, B. Sue
    Buckner, Samuel L.
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (11)
  • [47] ULTRASOUND B-MODE DESCRIPTORS AND THEIR ASSOCIATION TO AGE AND AUTOMATED IMT AND IMT VARIABILITY
    Meiburger, Kristen M.
    Rosati, Samanta
    Balestra, Gabriella
    Acharya, U. Rajendra
    Molinari, Filippo
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2016, 16 (01)
  • [48] Automated Lumen Segmentation and Estimation of Numerical Attributes of Common Carotid Artery Using Longitudinal B-Mode Ultrasound Images
    Ramasamy, Nandakumar
    Jayanthi, K. B.
    2013 IEEE POINT-OF-CARE HEALTHCARE TECHNOLOGIES (PHT), 2013, : 306 - 309
  • [49] Automated detection of the carotid artery wall in B-mode ultrasound images using active contours initialized by the Hough transform
    Stoitsis, J.
    Golemati, S.
    Kendros, S.
    Nikita, K. S.
    2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-8, 2008, : 3146 - 3149
  • [50] B-Mode Ultrasound Pose Recovery Via Surgical Fiducial Segmentation And Tracking
    Asoni, Alessandro
    Ketcha, Michael
    Kuo, Nathanael
    Chen, Lei
    Boctor, Emad
    Coon, Devin
    Prince, Jerry L.
    MEDICAL IMAGING 2015: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2015, 9415