Automated tracking of muscle fascicle orientation in B-mode ultrasound images

被引:80
|
作者
Rana, Manku [1 ]
Hamarneh, Ghassan [2 ]
Wakeling, James M. [1 ]
机构
[1] Simon Fraser Univ, Sch Biomed Physiol & Kinesiol, Burnaby, BC V5A 1S6, Canada
[2] Simon Fraser Univ, Med Image Anal Lab, Sch Comp Sci, Burnaby, BC V5A 1S6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Muscle fascicle tracking; Segmentation; Functional imaging; VASTUS LATERALIS MUSCLE; IN-VIVO MEASUREMENTS; LENGTH CHANGES; JOINT ANGLE; ARCHITECTURE; TENDON; BEHAVIOR; FIBER; HETEROGENEITY; PENNATION;
D O I
10.1016/j.jbiomech.2009.06.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
B-mode ultrasound can be used to non-invasively image muscle fascicles during both static and dynamic contractions. Digitizing these muscle fascicles can be a timely and subjective process, and usually studies have used the images to determine the linear fascicle lengths. However, fascicle orientations can vary along each fascicle (curvature) and between fascicles. The purpose of this study was to develop and test two methods for automatically tracking fascicle orientation. images were initially filtered using a multiscale vessel enhancement (a technique used to enhance tube-like structures), and then fascicle orientations quantified using either the Radon transform or wavelet analysis. Tests on synthetic images showed that these methods could identify fascicular orientation with errors of less than 0.06 degrees. Manual digitization of muscle fascicles during a dynamic contraction resulted in a standard deviation of angle estimates of 1.41 degrees across ten researchers. The Radon transform predicted fascicle orientations that were not significantly different from the manually digitized values, whilst the wavelet analysis resulted in angles that were 1.35 degrees less, and reasons for these differences are discussed. The Radon transform can be used to identify the dominant fascicular orientation within an image, and thus used to estimate muscle fascicle lengths. The wavelet analysis additionally provides information on the local fascicle orientations and can be used to quantify fascicle curvatures and regional differences with fascicle orientation across an image. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2068 / 2073
页数:6
相关论文
共 50 条
  • [21] Sparseland Model for Speckle Suppression of B-mode Ultrasound Images
    Srinivas, M.
    Bharath, R.
    Rajalakshmi, P.
    Mohan, C. Krishna
    2015 TWENTY FIRST NATIONAL CONFERENCE ON COMMUNICATIONS (NCC), 2015,
  • [22] Segmentation of ultrasound B-mode images with intensity inhomogeneity correction
    Xiao, GF
    Brady, M
    Noble, JA
    Zhang, YY
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (01) : 48 - 57
  • [23] Computer phantoms for simulating ultrasound B-mode and CFM images
    Jensen, JA
    Munk, P
    ACOUSTICAL IMAGING, VOL 23, 1997, 23 : 75 - 80
  • [24] A Robotic Ultrasound Scanner for Automatic Vessel Tracking and Three-Dimensional Reconstruction of B-Mode Images
    Merouche, Samir
    Allard, Louise
    Montagnon, Emmanuel
    Soulez, Gilles
    Bigras, Pascal
    Cloutier, Guy
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (01) : 35 - 46
  • [25] Application of Demons Algorithm in Ultrasound Elastography using B-Mode Ultrasound Images
    Tehrani, Ali Kafaei Zad
    Mozaffarzadeh, Moein
    Mardi, Zahra
    Hozhabr, Seyed Hani
    Mehrmohammadi, Mohammad
    Makkiabadi, Bahador
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2019, 2019, 10878
  • [26] A 3D motion tracking algorithm using ultrasound B-mode images: A feasibility study
    Li, Hongliang
    Cloutier, Guy
    Kadoury, Samuel
    Soulez, Gilles
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [27] Automatic Fascicle Length Estimation on Muscle Ultrasound Images With an Orientation-Sensitive Segmentation
    Zhou, Guang-Quan
    Zheng, Yong-Ping
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (12) : 2828 - 2836
  • [28] Estimating Full Regional Skeletal Muscle Fibre Orientation from B-Mode Ultrasound Images Using Convolutional, Residual, and Deconvolutional Neural Networks
    Cunningham, Ryan
    Sanchez, Maria B.
    May, Gregory
    Loram, Ian
    JOURNAL OF IMAGING, 2018, 4 (02)
  • [29] AW-Net: Automatic muscle structure analysis on B-mode ultrasound images for injury prevention
    Michard, Hugo
    Luvison, Bertrand
    Quoc-Cuong Pham
    Morales-Artacho, Antonio J.
    Guilhem, Gael
    12TH ACM CONFERENCE ON BIOINFORMATICS, COMPUTATIONAL BIOLOGY, AND HEALTH INFORMATICS (ACM-BCB 2021), 2021,
  • [30] AUTOMATED POSTERIOR WALL THICKNESS MEASUREMENT FROM B-MODE ULTRASOUND
    Annangi, Pavan
    Subramanian, Navneeth
    Govind, Satish
    Swamy, Gokul
    Young, Brian
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 77 - 80