Automated tracking of muscle fascicle orientation in B-mode ultrasound images

被引:80
|
作者
Rana, Manku [1 ]
Hamarneh, Ghassan [2 ]
Wakeling, James M. [1 ]
机构
[1] Simon Fraser Univ, Sch Biomed Physiol & Kinesiol, Burnaby, BC V5A 1S6, Canada
[2] Simon Fraser Univ, Med Image Anal Lab, Sch Comp Sci, Burnaby, BC V5A 1S6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Muscle fascicle tracking; Segmentation; Functional imaging; VASTUS LATERALIS MUSCLE; IN-VIVO MEASUREMENTS; LENGTH CHANGES; JOINT ANGLE; ARCHITECTURE; TENDON; BEHAVIOR; FIBER; HETEROGENEITY; PENNATION;
D O I
10.1016/j.jbiomech.2009.06.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
B-mode ultrasound can be used to non-invasively image muscle fascicles during both static and dynamic contractions. Digitizing these muscle fascicles can be a timely and subjective process, and usually studies have used the images to determine the linear fascicle lengths. However, fascicle orientations can vary along each fascicle (curvature) and between fascicles. The purpose of this study was to develop and test two methods for automatically tracking fascicle orientation. images were initially filtered using a multiscale vessel enhancement (a technique used to enhance tube-like structures), and then fascicle orientations quantified using either the Radon transform or wavelet analysis. Tests on synthetic images showed that these methods could identify fascicular orientation with errors of less than 0.06 degrees. Manual digitization of muscle fascicles during a dynamic contraction resulted in a standard deviation of angle estimates of 1.41 degrees across ten researchers. The Radon transform predicted fascicle orientations that were not significantly different from the manually digitized values, whilst the wavelet analysis resulted in angles that were 1.35 degrees less, and reasons for these differences are discussed. The Radon transform can be used to identify the dominant fascicular orientation within an image, and thus used to estimate muscle fascicle lengths. The wavelet analysis additionally provides information on the local fascicle orientations and can be used to quantify fascicle curvatures and regional differences with fascicle orientation across an image. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2068 / 2073
页数:6
相关论文
共 50 条
  • [1] UltraTrack: Software for semi-automated tracking of muscle fascicles in sequences of B-mode ultrasound images
    Farris, Dominic James
    Lichtwark, Glen A.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2016, 128 : 111 - 118
  • [2] Automated regional analysis of B-mode ultrasound images of skeletal muscle movement
    Darby, John
    Hodson-Tole, Emma F.
    Costen, Nicholas
    Loram, Ian D.
    JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (02) : 313 - 327
  • [3] Semi-automated Tracing of Hamstring Muscle Architecture for B-mode Ultrasound Images
    Cronin, Kevin
    Delahunt, Eamonn
    Foley, Shane
    De Vito, Giuseppe
    McCarthy, Conor
    Cournane, Sean
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2022, 43 (01) : 23 - 28
  • [4] Detection and Tracking of Multiple Microbubbles in Ultrasound B-Mode Images
    Ackermann, Dimitri
    Schmitz, Georg
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (01) : 72 - 82
  • [5] Estimating Skeletal Muscle Fascicle Curvature From B-Mode Ultrasound Image Sequences
    Darby, John
    Li, Baihua
    Costen, Nicholas
    Loram, Ian
    Hodson-Tole, Emma
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (07) : 1935 - 1945
  • [6] Automated localization and segmentation techniques for B-mode ultrasound images: A review
    Meiburger, Kristen M.
    Acharya, U. Rajendra
    Molinari, Filippo
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 92 : 210 - 235
  • [7] Fully Automated Analysis of Muscle Architecture from B-Mode Ultrasound Images with DL_Track_US
    Ritsche, Paul
    V. Franchi, Martino
    Faude, Oliver
    Finni, Taija
    Seynnes, Olivier
    Cronin, Neil J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (02): : 258 - 267
  • [8] Automated detection of skeletal muscle twitches from B-mode ultrasound images: An application to Motor Neuron Disease
    Harding, Peter J.
    Hodson-Tole, Emma F.
    Cunningham, Ryan
    Loram, Ian
    Costen, Nicholas
    2012 21ST INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION (ICPR 2012), 2012, : 2630 - 2633
  • [9] Improving B-mode ultrasound medical images
    Lanzolla, A. M. L.
    Andria, G.
    Attivissimo, F.
    Cavone, G.
    Giaquinto, N.
    2011 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2011, : 1704 - 1708
  • [10] Automatic ROI Placement in the Upper Trapezius Muscle in B-mode Ultrasound Images
    Behr, Michael
    McNabb, Evan
    Noseworthy, Michael
    Sidkar, Siddhartha
    Kumbhare, Dinesh
    ULTRASONIC IMAGING, 2019, 41 (04) : 231 - 246