Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysis

被引:103
|
作者
Sun, Zhonghua [1 ]
Jiang, Wen [1 ]
机构
[1] Curtin Univ Technol, Dept Imaging & Appl Phys, Discipline Med Imaging, Perth, WA 6845, Australia
关键词
coronary artery disease; computed tomography; angiography; diagnostic value; meta-analysis;
D O I
10.1016/j.ejrad.2006.06.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To perform a meta-analysis of the diagnostic value of multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography. Materials and methods: A search of PubMed and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analyzed at segment-, vessel- and patient-based assessment. Results: 47 studies (67 comparisons) met the criteria and were included in our study. Pooled overall sensitivity, specificity and 95% confidence interval for MSCT angiography in the detection of CAD were 83% (79%, 89%), 93% (91%, 96%) at segment-based analysis; 90% (87%, 94%), 87% (80%, 93%) at vessel-based analysis; and 91% (88%, 95%), 86% (81%, 92%) at patient-based analysis, respectively. Diagnostic accuracy of MSCT angiography in evaluating assessable segments was significantly improved with 64-slice scanners when compared to that with 4- and 16-slice scanners (p < 0.05). Conclusion: Our meta-analysis showed that MSCT angiography has potential diagnostic accuracy in the detection of CAD. Diagnostic performance of MSCT angiography has been significantly improved with the latest 64-slice CT, with resultant high qualitative and quantitative diagnostic accuracy. 16-slice CT was limited in spatial resolution which makes it difficult to perform quantitative assessment of coronary artery stenoses. (C) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 50 条
  • [1] Value of multislice computed tomography coronary angiography in suspected coronary artery disease
    Nasir, Khurram
    Budof, Matthew J.
    Shaw, Leslee J.
    Blumenthal, Roger S.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (20) : 2070 - 2071
  • [2] Value of multislice computed tomography coronary angiography in suspected coronary artery disease - Reply
    Schuijf, Joanne D.
    PundAute, Gabija
    Bax, Jeroen J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (20) : 2071 - 2071
  • [3] DIAGNOSTIC VALUE OF 320-SLICE COMPUTED TOMOGRAPHY ANGIOGRAPHY IN CORONARY ARTERY STENOSIS: A META-ANALYSIS
    Liao Xue-wen
    Tan Meng-wei
    Li Li
    [J]. HEART, 2013, 99 : E232 - E232
  • [4] Multislice computed tomography angiography in the diagnosis of coronary artery disease
    Sun, Zhong-Hua
    Cao, Yan
    Li, Hua-Feng
    [J]. JOURNAL OF GERIATRIC CARDIOLOGY, 2011, 8 (02) : 104 - 113
  • [5] Prognostic Value of Cardiac Computed Tomography Angiography in Patients with Suspected Coronary Artery Disease: A Meta-Analysis
    Jiang, Binghu
    Wang, Jichen
    Lv, Xianjun
    Cai, Wei
    [J]. CARDIOLOGY, 2014, 128 (04) : 304 - 312
  • [6] Prognostic value of multislice computed tomography coronary angiography in patients with known or suspected coronary artery disease
    Pundziute, Gabija
    Schuijf, Joanne D.
    Jukema, J. Wouter
    Boersma, Eric
    de Roos, Albert
    van der Wall, Ernst E.
    Bax, Jeroen J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (01) : 62 - 70
  • [7] Diagnostic performance of multislice spiral computed tomography of coronary arteries as compared with conventional invasive coronary angiography - A meta-analysis
    Hamon, Michele
    Biondi-Zoccai, Giuseppe G. L.
    Malagutti, Patrizia
    Agostoni, Pierfrancesco
    Morello, Remy
    Valgimigli, Marco
    Hamon, Martial
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (09) : 1896 - 1910
  • [8] Meta-analysis of comparative diagnostic performance of magnetic resonance imaging and multislice computed tomography for noninvasive coronary angiography
    Schuijf, JD
    Bax, JJ
    Shaw, LJ
    de Roos, A
    Lamb, HJ
    van der Wall, EE
    Wijns, W
    [J]. AMERICAN HEART JOURNAL, 2006, 151 (02) : 404 - 411
  • [9] Diagnostic performance of coronary computed tomography angiography versus exercise electrocardiography for coronary artery disease: a systematic review and meta-analysis
    Yin, Xinxin
    Wang, Jiali
    Zheng, Wen
    Ma, Jingjing
    Hao, Panpan
    Chen, Yuguo
    [J]. JOURNAL OF THORACIC DISEASE, 2016, 8 (07) : 1688 - +
  • [10] Impact of coronary calcium score on diagnostic accuracy of multislice computed tomography coronary angiography for detection of coronary artery disease
    Pundziute, Gabija
    Schuijf, Joanne D.
    Jukema, J. Wouter
    Lamb, Hildo J.
    de Roos, Albert
    van der Wall, Ernst E.
    Bax, Jeroen J.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (01) : 36 - 43