Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysis

被引:104
|
作者
Sun, Zhonghua [1 ]
Jiang, Wen [1 ]
机构
[1] Curtin Univ Technol, Dept Imaging & Appl Phys, Discipline Med Imaging, Perth, WA 6845, Australia
关键词
coronary artery disease; computed tomography; angiography; diagnostic value; meta-analysis;
D O I
10.1016/j.ejrad.2006.06.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To perform a meta-analysis of the diagnostic value of multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography. Materials and methods: A search of PubMed and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analyzed at segment-, vessel- and patient-based assessment. Results: 47 studies (67 comparisons) met the criteria and were included in our study. Pooled overall sensitivity, specificity and 95% confidence interval for MSCT angiography in the detection of CAD were 83% (79%, 89%), 93% (91%, 96%) at segment-based analysis; 90% (87%, 94%), 87% (80%, 93%) at vessel-based analysis; and 91% (88%, 95%), 86% (81%, 92%) at patient-based analysis, respectively. Diagnostic accuracy of MSCT angiography in evaluating assessable segments was significantly improved with 64-slice scanners when compared to that with 4- and 16-slice scanners (p < 0.05). Conclusion: Our meta-analysis showed that MSCT angiography has potential diagnostic accuracy in the detection of CAD. Diagnostic performance of MSCT angiography has been significantly improved with the latest 64-slice CT, with resultant high qualitative and quantitative diagnostic accuracy. 16-slice CT was limited in spatial resolution which makes it difficult to perform quantitative assessment of coronary artery stenoses. (C) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 50 条
  • [41] Diagnostic value of 320-slice coronary CT angiography in coronary artery disease: A systematic review and meta-analysis
    [J]. Lin, Chenghsun (jslin@ctust.edu.tw), 1600, Bentham Science Publishers (10):
  • [42] Noninvasive coronary angiography with multislice computed tomography
    Hoffmann, MHK
    Shi, HS
    Schmitz, BL
    Schmid, FT
    Lieberknecht, ML
    Schulze, R
    Ludwig, B
    Kroschel, U
    Jahnke, N
    Haerer, W
    Brambs, HJ
    Aschoff, AJ
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (20): : 2471 - 2478
  • [43] Prevalence and morphology of coronary artery ectasia using multislice computed tomography coronary angiography
    Galal, R.
    Farrag, A.
    El-Faramawy, A. M. R.
    Ghareeb, S.
    Salem, M. O. H. Ali
    Alini, Kasr
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 : 138 - 139
  • [44] Diagnostic accuracy of coronary computed tomography angiography in ischemic workup of heart failure: a meta-analysis
    Tiwari, Nidhish
    Nagraj, Sanjana
    Tzoumas, Andreas
    Arfaras-Melainis, Angelos
    Katamreddy, Adarsh
    Sohal, Sumit
    Palaiodimos, Leonidas
    [J]. FUTURE CARDIOLOGY, 2022, 18 (04) : 325 - 335
  • [45] Meta-analysis: Diagnostic Performance of Low-Radiation-Dose Coronary Computed Tomography Angiography
    von Ballmoos, Moritz Wyler
    Haring, Bernhard
    Juillerat, Pascal
    Alkadhi, Hatem
    [J]. ANNALS OF INTERNAL MEDICINE, 2011, 154 (06) : 413 - +
  • [46] Whole-heart coronary magnetic resonance angiography: Value for the detection of coronary artery stenoses in comparison to multislice computed tomography angiography
    Maintz, D.
    Ozgun, M.
    Hoffmeier, A.
    Quante, M.
    Fischbach, R.
    Manning, W. J.
    Heindel, W.
    Botnar, R. M.
    [J]. ACTA RADIOLOGICA, 2007, 48 (09) : 967 - 973
  • [47] Multislice computed tomography and exercise electrocardiography for detection of coronary artery disease:: Intraindividual comparison with conventional coronary angiography
    Dewey, Marc
    Duebel, Hans-Peter
    Schink, Tanis
    Baumann, Gert
    Hamm, Bernd
    [J]. CIRCULATION, 2006, 114 (18) : 818 - 818
  • [48] Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses
    Knez, A
    Becker, CR
    Leber, A
    Ohnesorge, B
    Becker, A
    White, C
    Haberl, R
    Reiser, MF
    Steinbeck, G
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (10): : 1191 - +
  • [49] A meta-analysis comparing the diagnostic performance of computed tomography-derived fractional flow reserve and coronary computed tomography angiography at different levels of coronary artery calcium score
    Ma, Zhao
    Tu, Chenchen
    Zhang, Baoen
    Zhang, Dongfeng
    Song, Xiantao
    Zhang, Hongjia
    [J]. EUROPEAN RADIOLOGY, 2024, 34 (9) : 5621 - 5632
  • [50] Diagnostic performance of computed tomography angiography in the detection of coronary artery in-stent restenosis: evidence from an updated meta-analysis
    Dai, Tao
    Wang, Jiang-rong
    Hu, Peng-fei
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (04) : 1373 - 1382