FASEA: A FPGA Acquisition System and Software Event Analysis for liquid scintillation counting

被引:27
|
作者
Steele, T. [1 ]
Mo, L. [1 ]
Bignell, L. [1 ,2 ]
Smith, M. [3 ]
Alexiev, D. [1 ]
机构
[1] Australian Nucl Sci & Technol Org, Menai, NSW 2234, Australia
[2] Univ Sydney, Sch Phys, Sydney, NSW 2006, Australia
[3] Australian Natl Univ, RSPhysSE, Canberra, ACT, Australia
关键词
FPGA; TDCR; Liquid scintillation; FASEA;
D O I
10.1016/j.nima.2009.07.045
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The FASEA (FPGA based Acquisition and Software Event Analysis) system has been developed to replace the MAC3 for coincidence pulse processing. The system uses a National Instruments Virtex 5 FPGA card (PXI-7842R) for data acquisition and a purpose developed data analysis software for data analysis. Initial comparisons to the MAC3 unit are included based on measurements of Sr-89 and H-3,confirming that the system is able to accurately emulate the behaviour of the MAC3 unit. Crown Copyright (C) 2009 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:217 / 220
页数:4
相关论文
共 50 条
  • [31] LIQUID SCINTILLATION-COUNTING FROM GROSS COUNTS TO SPECTRAL-ANALYSIS
    RING, JG
    NGUYEN, NC
    EVERETT, LJ
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1980, 31 (01): : 5 - 6
  • [32] Determination of sulfur in steels by radiochemical neutron activation analysis with liquid scintillation counting
    Paul, R. L.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (01) : 243 - 249
  • [33] SUBSTOICHIOMETRIC ISOTOPE-DILUTION ANALYSIS OF INDIUM BY LIQUID SCINTILLATION-COUNTING
    RAJESH, N
    JACOB, J
    SUBRAMANIAN, MS
    RADIOCHIMICA ACTA, 1993, 62 (1-2) : 101 - 104
  • [34] APPLICATIONS OF PULSE-HEIGHT SPECTRUM ANALYSIS IN LIQUID SCINTILLATION-COUNTING
    KOLB, AJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1981, 39 : 22 - 23
  • [35] Analysis of radioactive strontium-90 in food by Cerenkov liquid scintillation counting
    Pan, Jingjing
    Emanuele, Kathryn
    Maher, Eileen
    Lin, Zhichao
    Healey, Stephanie
    Regan, Patrick
    APPLIED RADIATION AND ISOTOPES, 2017, 126 : 214 - 218
  • [36] Performance Analysis of Embedded System for Data Acquisition on FPGA
    Rani, B. Jhansi
    Sudhir, A. Ch.
    Vidhyavathi, T.
    SOFT COMPUTING IN DATA ANALYTICS, SCDA 2018, 2019, 758 : 409 - 416
  • [37] Design and Implementation of ARM and FPGA Based Data Acquisition System Software and Hardware
    Zheng, Dezhi
    Na, Rui
    Fan, Shangchun
    Liu, Yudong
    2015 2ND INTERNATIONAL CONFERENCE ON MECHATRONIC SYSTEMS AND MATERIALS APPLICATION (ICMSMA 2015), 2015, : 159 - 164
  • [38] Thermal neutron flux measurements using lithium carbonate and liquid scintillation counting system
    Kolekar, R. V.
    Bhade, S. P. D.
    Kumar, Rajiv
    Reddy, Priyanka
    Singh, Rajvir
    Pradeepkumar, K. S.
    CURRENT SCIENCE, 2015, 109 (02): : 255 - 257
  • [39] Development of 3-PM liquid scintillation counting system with geometrical efficiency variation
    Hwang, HY
    Kwak, SI
    Lee, HY
    Lee, JM
    Lee, KB
    Park, TS
    APPLIED RADIATION AND ISOTOPES, 2004, 60 (2-4) : 469 - 473
  • [40] MEASUREMENT OF TRITIATED STEROID IN A 2-PHASE LIQUID SCINTILLATION-COUNTING SYSTEM
    EVANS, JJ
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (12): : 1619 - 1621