Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study

被引:25
|
作者
Yan, Shuang G. [1 ,2 ]
Chevalier, Yan [2 ]
Liu, Fanxiao [2 ,3 ]
Hua, Xingyi [1 ]
Schreiner, Anna [4 ]
Jansson, Volkmar [2 ]
Schmidutz, Florian [2 ,4 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Orthopaed Surg, 1 Baicao Rd, Hefei 230088, Peoples R China
[2] Univ Munich LMU, Dept Orthopaed Surg Phys Med & Rehabil, Munich, Germany
[3] Shandong First Med Univ, Shandong Prov Hosp, Dept Orthopaed, 324 Rd Jing Wu Wei Qi, Jinan 250021, Shandong, Peoples R China
[4] Eberhard Karls Univ Tuebingen, BG Trauma Ctr Tuebingen, Schnarrenbergstr 95, D-72076 Tubingen, Germany
关键词
Stress shielding; Finite element analysis; Total hip arthroplasty; SHA; Stem; METHA SHORT STEM; PRIMARY STABILITY; DXA; AGE;
D O I
10.1186/s13018-020-02027-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Short stem total hip arthroplasty (SHA) preserves femoral bone stock and is supposed to provide a more natural load transfer compared to standard stem total hip arthroplasty (THA). As comparative biomechanical reference data are rare we used a finite element analysis (FEA) approach to compare cortical load transfer after implantations of a metaphyseal anchoring short and standard stem in native biomechanical femora. Methods The subject specific finite element models of biomechanical femora, one native and two with implanted metaphyseal anchoring SHA (Metha, B. Braun Aesculap) and standard THA (CLS, Zimmer-Biomet), were generated from computed tomography datasets. The loading configuration was performed with an axial force of 1400 N. Von Mises stress was used to investigate the change of cortical stress distribution. Results Compared to the native femur, a considerable reduction of cortical stress was recorded after implantation of SHA and standard THA. The SHA showed less reduction proximally with a significant higher metaphyseal cortical stress compared to standard THA. Moreover, the highest peak stresses were observed metaphyseal for the SHA stem while for the standard THA high stress pattern was observed more distally. Conclusions Both, short and standard THA, cause unloading of the proximal femur. However, the metaphyseal anchoring SHA features a clearly favorable pattern in terms of a lower reduction proximally and improved metaphyseal loading, while standard THA shows a higher proximal unloading and more distal load transfer. These load patterns implicate a reduced stress shielding proximally for metaphyseal anchoring SHA stems and might be able to translate in a better bone preservation.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study
    Shuang G. Yan
    Yan Chevalier
    Fanxiao Liu
    Xingyi Hua
    Anna Schreiner
    Volkmar Jansson
    Florian Schmidutz
    Journal of Orthopaedic Surgery and Research, 15
  • [2] Bionic reconstruction of tension trabeculae in short-stem hip arthroplasty: a finite element analysis
    Zhentao Ding
    Jun Wang
    Yanhua Wang
    Xiaomeng Zhang
    Yong Huan
    Dianying Zhang
    BMC Musculoskeletal Disorders, 24
  • [3] Bionic reconstruction of tension trabeculae in short-stem hip arthroplasty: a finite element analysis
    Ding, Zhentao
    Wang, Jun
    Wang, Yanhua
    Zhang, Xiaomeng
    Huan, Yong
    Zhang, Dianying
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [4] Finite Element Analysis of Cemented Hip Arthroplasty: Influence of Stem Tapers
    Abdullah, Abdul H.
    Asri, Mohd N. Mohd
    Alias, Mohd S.
    Giha, Tardan
    INTERNATIONAL MULTICONFERENCE OF ENGINEERS AND COMPUTER SCIENTISTS (IMECS 2010), VOLS I-III, 2010, : 2241 - +
  • [5] Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty
    Matthew Jian-Qiao Peng
    Hai-Yan Chen
    Yong Hu
    XiangYang Ju
    Bo Bai
    BMC Musculoskeletal Disorders, 18
  • [6] Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty
    Peng, Matthew Jian-Qiao
    Chen, Hai-Yan
    Hu, Yong
    Ju, XiangYang
    Bai, Bo
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [7] A Time-Dependent Design Concept of a Cementless Hip Stem Prosthesis for Improving Physiological Load Transfer in Proximal Femur: A Finite Element Analysis
    Huang, Chun-Chieh
    Cheng, Cheng-Kung
    Wei, Hung-Wen
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2022, 42 (04) : 414 - 421
  • [8] A Time-Dependent Design Concept of a Cementless Hip Stem Prosthesis for Improving Physiological Load Transfer in Proximal Femur: A Finite Element Analysis
    Chun-Chieh Huang
    Cheng-Kung Cheng
    Hung-Wen Wei
    Journal of Medical and Biological Engineering, 2022, 42 : 414 - 421
  • [9] Early clinical and functional results of short modular femoral metaphyseal stem hip arthroplasty: a pilot study
    Karampinas, Panagiotis
    Vlamis, John
    Papadelis, Eustratios
    Pneumatikos, Spiros
    CURRENT ORTHOPAEDIC PRACTICE, 2016, 27 (06): : 618 - 622
  • [10] Bone remodeling after total hip arthroplasty with a short stemmed metaphyseal loading implant: Finite element analysis validated by a prospective DEXA investigation
    Lerch, Matthias
    Kurtz, Agnes
    Stukenborg-Colsman, Christina
    Nolte, Ingo
    Weigel, Nelly
    Bouguecha, Anas
    Behrens, Bernd A.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (11) : 1822 - 1829