Monitoring Moisture Performance of Cross-Laminated Timber Building Elements during Construction

被引:39
|
作者
Schmidt, Evan [1 ]
Riggio, Mariapaola [1 ]
机构
[1] Oregon State Univ, Coll Forestry, Wood Sci & Engn Dept, Corvallis, OR 97331 USA
基金
美国食品与农业研究所;
关键词
mass timber buildings; moisture performance; cross-laminated timber; CLT; hygrothermal monitoring; WOOD; MANAGEMENT; BEHAVIOR; METERS; PANELS; RAIN;
D O I
10.3390/buildings9060144
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
There are currently no standards regulating water management for mass timber elements during construction, little knowledge of impacts of moisture exposure (wetting and drying performance, dimensional stability, checking), and few precedents serving as guidelines for monitoring moisture response of mass timber. To address these gaps, a hygrothermal monitoring study was devised to track moisture performance of U.S. made cross laminated timber (CLT) and glulam at a three-story mass timber building. This paper discusses moisture measurements that were collected during the first six months of construction at a CLT rocking shear wall and a timber floor connection. Despite the limited number of structural systems monitored during construction, the distribution and number of sensors in these elements allow to draw some important conclusions. The data confirmed that moisture distribution and wetting/drying rates varied based on local conditions and details (aspect, coatings, connections, etc.), with measurements at an uncoated, north-facing area showing the highest moisture levels (reaching fiber saturation at multiple ply depths and locations). Most locations rarely exceeded 16% moisture content for more than a few months. Certain moisture-trapping details consistently showed higher moisture levels (i.e., above 16%) and poorer drying. Some interior plies continued to show slow increases in MC even after months of drying conditions. These observations suggest preventative approaches implementable in the design (e.g., avoiding moisture trapping details), during fabrication (e.g., localized coating), and construction (e.g., sequencing installation to minimize exposure and allow drying).
引用
收藏
页数:23
相关论文
共 50 条
  • [21] Adoption of unconventional approaches in construction: The case of cross-laminated timber
    Jones, Kell
    Stegemann, Julia
    Sykes, Judith
    Winslow, Peter
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 125 : 690 - 702
  • [22] Scientometric Analysis for Cross-Laminated Timber in the Context of Construction 4.0
    Villanueva, Emanuel Martinez
    Castaneda, Jennifer Alejandra Cardenas
    Ahmad, Rafiq
    AUTOMATION, 2022, 3 (03): : 439 - 470
  • [23] Status of cross-laminated timber construction in North-America
    Gagnon, S.
    Karacabeyli, E.
    STRUCTURES AND ARCHITECTURE: CONCEPTS: APPLICATIONS AND CHALLENGES, 2013, : 66 - 73
  • [24] Moisture risk assessment of cross-laminated timber walls: Perspectives on climate conditions and water vapor resistance performance of building materials
    Chang, Seong Jin
    Wi, Seunghwan
    Kang, Seog Goo
    Kim, Sumin
    BUILDING AND ENVIRONMENT, 2020, 168
  • [25] Environmental Impacts of Building Construction Using Cross-laminated Timber Panel Construction Method: A Case of the Research Building in Kyushu, Japan
    Nakano, Katsuyuki
    Karube, Masahiko
    Hattori, Nobuaki
    SUSTAINABILITY, 2020, 12 (06) : 1 - 14
  • [26] Study on in-plane compressive performance of cross-laminated bamboo and timber (CLBT) wall elements
    Hao Li
    Libin Wang
    Brad Jianhe Wang
    Yang Wei
    European Journal of Wood and Wood Products, 2023, 81 : 343 - 355
  • [27] Behaviour of Loaded Cross-Laminated Timber Wall Elements in Fire Conditions
    Joachim Schmid
    Agnese Menis
    Massimo Fragiacomo
    Isaia Clemente
    Giovanna Bochicchio
    Fire Technology, 2015, 51 : 1341 - 1370
  • [28] Experimental verification of design procedure for elements from cross-laminated timber
    Buka-Vaivade, Karina
    Serdjuks, Dmitrijs
    Goremikins, Vadims
    Vilguts, Aivars
    Pakrastins, Leonids
    MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 2017, 172 : 1212 - 1219
  • [29] Behaviour of Loaded Cross-Laminated Timber Wall Elements in Fire Conditions
    Schmid, Joachim
    Menis, Agnese
    Fragiacomo, Massimo
    Clemente, Isaia
    Bochicchio, Giovanna
    FIRE TECHNOLOGY, 2015, 51 (06) : 1341 - 1370
  • [30] Design Methods of Elements from Cross-Laminated Timber Subjected to Flexure
    Vilguts, Aivars
    Serdjuks, Dmitrijs
    Pakrastins, Leonids
    INTERNATIONAL SCIENTIFIC CONFERENCE URBAN CIVIL ENGINEERING AND MUNICIPAL FACILITIES (SPBUCEMF-2015), 2015, 117 : 10 - 19