Behaviour of Loaded Cross-Laminated Timber Wall Elements in Fire Conditions

被引:27
|
作者
Schmid, Joachim [1 ,2 ]
Menis, Agnese [3 ]
Fragiacomo, Massimo [3 ]
Clemente, Isaia [4 ]
Bochicchio, Giovanna [5 ]
机构
[1] SP Tech Res Inst Sweden, Wood Technol, Dept Civil Environm & Nat Resources Engn, Stockholm, Sweden
[2] Lulea Univ Technol, Stockholm, Sweden
[3] Univ Sassari, Dept Architecture & Urban Planning, Alghero, Italy
[4] Univ Trieste, Trieste, Italy
[5] CNR, Ivalsa Trees & Timber Inst, San Michele All Adige, Italy
关键词
Cross-laminated timber; Fire tests; Reduced cross-section method; Wall member; TESTS;
D O I
10.1007/s10694-015-0516-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Cross-laminated timber (CLT) is increasingly being used in medium-rise timber buildings for a number of reasons, such as rapidity of construction, cost effectiveness and robustness. Like for other building materials, verification of the load-bearing performance in fire conditions is an important issue. Experimental fire tests have been performed on loaded CLT wall elements at research institutes in Sweden and Italy. In total, three large-scale and four medium-scale tests have been carried out. The aim was to gain information about initially protected and unprotected elements, to be used for classification and also for validation of calculation models. In the test series, reference tests at normal temperature were included to obtain information (e.g. stiffness, strength) about the material tested in fire conditions. In addition, model-scale fire tests were performed to investigate the loss in stiffness resulting from fire exposure and the effect of different protection types. Loaded fire tests varied in the range of 41.8 min to 120 min, depending on the CLT structure, the level of load, and the type of protection. Data on temperature within specimens and residual cross-sections were collected. Charring rates evaluated from experimental results were comparable with values proposed by Eurocode for the design of timber structures. Conservative solutions were obtained by using simplified design methods and comparing their results to test results and results of advanced modelling. It was shown that the load-bearing performance of CLT may show abrupt changes due to its layered structure. It is strongly recommended that a minimum residual depth depending on the CLT structure should be required in order to ensure robust building products.
引用
收藏
页码:1341 / 1370
页数:30
相关论文
共 50 条
  • [1] Behaviour of Loaded Cross-Laminated Timber Wall Elements in Fire Conditions
    Joachim Schmid
    Agnese Menis
    Massimo Fragiacomo
    Isaia Clemente
    Giovanna Bochicchio
    [J]. Fire Technology, 2015, 51 : 1341 - 1370
  • [2] Fire behaviour of cross-laminated timber
    Klippel, Michael
    Frangi, Andrea
    [J]. BAUTECHNIK, 2016, 93 (08) : 567 - 572
  • [3] Experimental and numerical analysis on fire behaviour of loaded cross-laminated timber panels
    Wang, Yuexiang
    Zhang, Jin
    Mei, Fang
    Liao, Jianan
    Li, Weibin
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (01) : 22 - 36
  • [4] The Structural Behaviour of Cross-Laminated Timber Rib Panels in Fire
    Kleinhenz, Miriam
    Just, Alar
    Frangi, Andrea
    [J]. FIRE TECHNOLOGY, 2024, 60 (04) : 2651 - 2673
  • [5] Influence of wall assembly on behaviour of cross-laminated timber buildings
    Pozza, Luca
    Scotta, Roberto
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2015, 168 (04) : 275 - 286
  • [6] Design of Cross-Laminated Timber in Fire
    Klippel, Michael
    Schmid, Joachim
    [J]. STRUCTURAL ENGINEERING INTERNATIONAL, 2017, 27 (02) : 224 - 230
  • [7] Fire Resistance of Cross-Laminated Timber Panels Loaded Out of Plane
    Fragiacomo, Massimo
    Menis, Agnese
    Clemente, Isaia
    Bochicchio, Giovanna
    Ceccotti, Ario
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (12)
  • [8] Fire Resistance Test and Numerical Simulation of Cross-Laminated Timber Wall
    Zhang, Jin
    Liu, Delong
    Zhang, Qiang
    Bai, Yu
    [J]. Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2021, 49 (04): : 9 - 19
  • [9] Effect of protective cladding on the fire performance of vertically loaded cross-laminated timber (CLT) wall panels
    Yasir, Muhammad
    Macilwraith, Andrew
    O'Ceallaigh, Conan
    Ruane, Kieran
    [J]. JOURNAL OF STRUCTURAL INTEGRITY AND MAINTENANCE, 2023, : 199 - 208
  • [10] Structural response of cross-laminated timber compression elements exposed to fire
    Wiesner, Felix
    Randmael, Fredrik
    Wan, Wing
    Bisby, Luke
    Hadden, Rory M.
    [J]. FIRE SAFETY JOURNAL, 2017, 91 : 56 - 67