Behaviour of Loaded Cross-Laminated Timber Wall Elements in Fire Conditions

被引:27
|
作者
Schmid, Joachim [1 ,2 ]
Menis, Agnese [3 ]
Fragiacomo, Massimo [3 ]
Clemente, Isaia [4 ]
Bochicchio, Giovanna [5 ]
机构
[1] SP Tech Res Inst Sweden, Wood Technol, Dept Civil Environm & Nat Resources Engn, Stockholm, Sweden
[2] Lulea Univ Technol, Stockholm, Sweden
[3] Univ Sassari, Dept Architecture & Urban Planning, Alghero, Italy
[4] Univ Trieste, Trieste, Italy
[5] CNR, Ivalsa Trees & Timber Inst, San Michele All Adige, Italy
关键词
Cross-laminated timber; Fire tests; Reduced cross-section method; Wall member; TESTS;
D O I
10.1007/s10694-015-0516-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Cross-laminated timber (CLT) is increasingly being used in medium-rise timber buildings for a number of reasons, such as rapidity of construction, cost effectiveness and robustness. Like for other building materials, verification of the load-bearing performance in fire conditions is an important issue. Experimental fire tests have been performed on loaded CLT wall elements at research institutes in Sweden and Italy. In total, three large-scale and four medium-scale tests have been carried out. The aim was to gain information about initially protected and unprotected elements, to be used for classification and also for validation of calculation models. In the test series, reference tests at normal temperature were included to obtain information (e.g. stiffness, strength) about the material tested in fire conditions. In addition, model-scale fire tests were performed to investigate the loss in stiffness resulting from fire exposure and the effect of different protection types. Loaded fire tests varied in the range of 41.8 min to 120 min, depending on the CLT structure, the level of load, and the type of protection. Data on temperature within specimens and residual cross-sections were collected. Charring rates evaluated from experimental results were comparable with values proposed by Eurocode for the design of timber structures. Conservative solutions were obtained by using simplified design methods and comparing their results to test results and results of advanced modelling. It was shown that the load-bearing performance of CLT may show abrupt changes due to its layered structure. It is strongly recommended that a minimum residual depth depending on the CLT structure should be required in order to ensure robust building products.
引用
收藏
页码:1341 / 1370
页数:30
相关论文
共 50 条
  • [41] Shear behavior of cross-laminated timber wall consisting of small panels
    Oh, Jung-Kwon
    Hong, Jung-Pyo
    Kim, Chul-Ki
    Pang, Sung-Jun
    Lee, Sang-Joon
    Lee, Jun-Jae
    [J]. JOURNAL OF WOOD SCIENCE, 2017, 63 (01) : 45 - 55
  • [42] Modelling the mechanical behaviour of typical wall-to-floor connection systems for cross-laminated timber structures
    Izzi, Matteo
    Polastri, Andrea
    Fragiacomo, Massimo
    [J]. ENGINEERING STRUCTURES, 2018, 162 : 270 - 282
  • [43] Fire spread in a large compartment with exposed cross-laminated timber and open ventilation conditions: #FRIC-02-Exposed wall and ceiling
    Boe, Andreas Saeter
    Friquin, Kathinka Leikanger
    Brandon, Daniel
    -Hansen, Anne Steen
    Ertesvag, Ivar S.
    [J]. FIRE SAFETY JOURNAL, 2023, 141
  • [44] Shear behavior of cross-laminated timber wall consisting of small panels
    Jung-Kwon Oh
    Jung-Pyo Hong
    Chul-Ki Kim
    Sung-Jun Pang
    Sang-Joon Lee
    Jun-Jae Lee
    [J]. Journal of Wood Science, 2017, 63 : 45 - 55
  • [45] Experimental verification of design procedure for elements from cross-laminated timber
    Buka-Vaivade, Karina
    Serdjuks, Dmitrijs
    Goremikins, Vadims
    Vilguts, Aivars
    Pakrastins, Leonids
    [J]. MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 2017, 172 : 1212 - 1219
  • [46] Design Methods of Elements from Cross-Laminated Timber Subjected to Flexure
    Vilguts, Aivars
    Serdjuks, Dmitrijs
    Pakrastins, Leonids
    [J]. INTERNATIONAL SCIENTIFIC CONFERENCE URBAN CIVIL ENGINEERING AND MUNICIPAL FACILITIES (SPBUCEMF-2015), 2015, 117 : 10 - 19
  • [47] Hygrothermal performance of cross-laminated timber wall assemblies: A stochastic approach
    Wang, Lin
    Ge, Hua
    [J]. BUILDING AND ENVIRONMENT, 2016, 97 : 11 - 25
  • [48] Vibrations of Cross-Laminated Timber Floors
    Kozaric, Ljiljana
    Purcar, Martina Vojnic
    Zivkovic, Smilja
    [J]. DRVNA INDUSTRIJA, 2019, 70 (03) : 307 - 312
  • [49] Experimental analysis of cross-laminated timber rib panels at normal temperature and in fire
    Kleinhenz, Miriam
    Just, Alar
    Frangi, Andrea
    [J]. ENGINEERING STRUCTURES, 2021, 246
  • [50] Numerical Investigation of the Fire Resistance of Protected Cross-Laminated Timber Floor Panels
    Menis, Agnese
    Fragiacomo, Massimo
    Clemente, Isaia
    [J]. STRUCTURAL ENGINEERING INTERNATIONAL, 2012, 22 (04) : 523 - 532