Fire Resistance Test and Numerical Simulation of Cross-Laminated Timber Wall

被引:0
|
作者
Zhang, Jin [1 ]
Liu, Delong [1 ]
Zhang, Qiang [2 ]
Bai, Yu [1 ]
机构
[1] Key Laboratory of Concrete and Prestressed Concrete Structures of the Ministry of Education, Southeast University, Nanjing,211189, China
[2] ARTS Group Co., Ltd., Suzhou,215021, China
关键词
D O I
10.12141/j.issn.1000-565X.200253
中图分类号
学科分类号
摘要
In order to study the fire resistance of the cross-laminated timber (CLT) wall made of domestic Japanese larch, the CLT plate normal temperature material performance test and the CLT wall fire resistance test under the standard heating curve were carried out. The performance test obtained the interlayer shear strength, rolling shear strength and compressive strength along the grain of the CLT sheet. The fire resistance test results show that the failure mode of the wall at room temperature is mainly buckling failure, and the ultimate load of the three-layer CLT wall is higher than that of the five-layer CLT wall. Under the same layer composition, the fire resistance of the CLT wall decreases with the increase of the load-holding ratio of the test piece. Under the same load-holding ratio, the fire resistance of the five-layer CLT wall is higher than that of the three-layer CLT wall. Moreover, the CLT wall did not fall off during the test. The numerical simulation with ABAQUS shows that the temperature field and displacement development trends obtained are basically consistent with the test results. © 2021, Editorial Department, Journal of South China University of Technology. All right reserved.
引用
收藏
页码:9 / 19
相关论文
共 50 条
  • [1] Simulation of the Fire Resistance of Cross-laminated Timber (CLT)
    Schmid, Joachim
    Klippel, Michael
    Just, Alar
    Frangi, Andrea
    Tiso, Mattia
    [J]. FIRE TECHNOLOGY, 2018, 54 (05) : 1113 - 1148
  • [2] Simulation of the Fire Resistance of Cross-laminated Timber (CLT)
    Joachim Schmid
    Michael Klippel
    Alar Just
    Andrea Frangi
    Mattia Tiso
    [J]. Fire Technology, 2018, 54 : 1113 - 1148
  • [3] Numerical simulation of fire integrity resistance of full-scale gypsum-faced cross-laminated timber wall
    Thi, V. D.
    Khelifa, M.
    Oudjene, M.
    El Ganaoui, M.
    Rogaume, Y.
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 132 : 96 - 103
  • [4] Numerical Analysis of Cross-Laminated Timber (CLT) Wall Panels Under Fire
    Yasir, Muhammad
    Ruane, Kieran
    Jaksic, Vesna
    [J]. WOOD & FIRE SAFETY 2024, WFS 2024, 2024, : 27 - 35
  • [5] Numerical Investigation of the Fire Resistance of Protected Cross-Laminated Timber Floor Panels
    Menis, Agnese
    Fragiacomo, Massimo
    Clemente, Isaia
    [J]. STRUCTURAL ENGINEERING INTERNATIONAL, 2012, 22 (04) : 523 - 532
  • [6] Fire behaviour of cross-laminated timber
    Klippel, Michael
    Frangi, Andrea
    [J]. BAUTECHNIK, 2016, 93 (08) : 567 - 572
  • [7] Design of Cross-Laminated Timber in Fire
    Klippel, Michael
    Schmid, Joachim
    [J]. STRUCTURAL ENGINEERING INTERNATIONAL, 2017, 27 (02) : 224 - 230
  • [8] Modelling the fire resistance of cross-laminated timber rib panels
    Kleinhenz, Miriam
    Palma, Pedro
    Just, Alar
    Frangi, Andrea
    [J]. FIRE AND MATERIALS, 2024,
  • [9] Scaling study on the fire resistance of cross-laminated timber floors
    Bai, Yu
    Zhang, Jin
    Zhang, Xilin
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 85
  • [10] Behaviour of Loaded Cross-Laminated Timber Wall Elements in Fire Conditions
    Joachim Schmid
    Agnese Menis
    Massimo Fragiacomo
    Isaia Clemente
    Giovanna Bochicchio
    [J]. Fire Technology, 2015, 51 : 1341 - 1370