Clinical Performance of Narrow-Diameter Titanium-Zirconium Implants: A Systematic Review

被引:19
|
作者
Badran, Zahi [1 ,2 ]
Struillou, Xavier [1 ,2 ]
Strube, Nicolas [1 ]
Bourdin, David [1 ]
Dard, Michel [3 ,4 ]
Soueidan, Assem [2 ]
Hoornaert, Alain [1 ]
机构
[1] Univ Nantes, Fac Dent Surg, Dept Oral Implantol, Nantes, France
[2] CHU Nantes, Fac Dent Surg, Dept Periodontol, INSERM,U791,UIC 11, Nantes, France
[3] NYU, Coll Dent, Dept Periodontol & Implant Dent, New York, NY USA
[4] Inst Straumann, Basel, Switzerland
关键词
Roxolid; dental implant; bone augmentation; RANDOMIZED CONTROLLED-TRIAL; DENTAL IMPLANTS; FOLLOW-UP; RADIOGRAPHIC EVALUATION; MECHANICAL-PROPERTIES; DOUBLE-BLIND; GRADE IV; ALLOY; SURVIVAL; SUCCESS;
D O I
10.1097/ID.0000000000000557
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:Implant-supported prosthetic rehabilitations are in constant augmentation in everyday dental practice. This is largely due to increasing demand from patients for fixed or implant-stabilized prosthesis, although they are frequently reticent to complex preimplant bone augmentation surgeries, whenever bone volume is lacking. Narrow-diameter implants (NDI; 3.5 mm) have been developed to offer relatively simple implant solutions in challenging bone-deficient sites. However, concerns regarding their mechanical properties have been raised. Special titanium-zirconium material (Ti-Zr), with superior mechanical resistance, compared with pure titanium alloys has been introduced into the market. The purpose of this systematic review was to determine the available data on clinical performance of Ti-Zr NDI.Materials and Methods:A literature search of all available clinical articles dealing with Ti-Zr NDI has been carried out. After including only prospective clinical trials, 14 papers were retrieved for thorough reviewing.Conclusion:Short-term results from preliminary clinical reports are quite promising, although the number of published studies and the follow-up periods are still insufficient to determine the real benefit of this hybrid material compared with titanium, especially when using NDI.
引用
收藏
页码:316 / 323
页数:8
相关论文
共 50 条
  • [1] Clinical outcomes of titanium-zirconium alloy narrow-diameter implants for single-crown restorations: a systematic review and meta-analysis
    Cao, Rongkai
    Chen, Beibei
    Xu, Hui
    Fan, Zhen
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2023, 61 (06): : 403 - 410
  • [2] Survival rate of titanium-zirconium narrow diameter dental implants versus commercially pure titanium narrow diameter dental implants: A systematic review
    Iegami, Carolina Mayumi
    Uehara, Priscila Nakasone
    Sesma, Newton
    Pannuti, Claudio Mendes
    Neto, Pedro Tortamano
    Mukai, Marcio Katsuyoshi
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (06) : 1015 - 1022
  • [3] Maxillary and mandibular overdentures retained by two unsplinted narrow-diameter titanium-zirconium implants - A clinical pilot study
    Kern, Jaana-Sophia
    Salin, Esra
    Elvers, Dirk
    Rittich, Anne
    Tuna, Taskin
    Hoelzle, Frank
    Wolfart, Stefan
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2024,
  • [4] TITANIUM-ZIRCONIUM NARROW-DIAMETER IMPLANTS MAY HAVE HIGH SURVIVAL RATES AFTER 1 YEAR
    Brignardello-Petersen, Romina
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2017, 148 (12): : E206 - E206
  • [5] Clinical performance of narrow-diameter titanium-zirconium implants in immediately loaded fixed full-arch prostheses: a 2-year clinical study
    Coskunses, Fatih Mehmet
    Tak, Onjen
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [6] Clinical analysis of the tooth-implant papilla for two narrow-diameter titanium-zirconium implants in the anterior area: prospective controlled clinical study
    Paola Herrera-Pérez
    Ana María García-De-La-Fuente
    Eztizen Andia-Larrea
    Xabier Marichalar-Mendia
    José Manuel Aguirre-Urizar
    Luis Antonio Aguirre-Zorzano
    [J]. BMC Oral Health, 24
  • [7] Systematic Review on Success of Narrow-Diameter Dental Implants
    Klein, Marc O.
    Schiegnitz, Eik
    Al-Nawas, Bilal
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 : 43 - 54
  • [8] Clinical analysis of the tooth-implant papilla for two narrow-diameter titanium-zirconium implants in the anterior area: prospective controlled clinical study
    Herrera-Perez, Paola
    Garcia-De-La-Fuente, Ana Maria
    Andia-Larrea, Eztizen
    Marichalar-Mendia, Xabier
    Aguirre-Urizar, Jose Manuel
    Aguirre-Zorzano, Luis Antonio
    [J]. BMC ORAL HEALTH, 2024, 24 (01)
  • [9] Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 3-year results of a randomized controlled clinical study
    Ioannidis, Alexis
    Gallucci, German O.
    Jung, Ronald E.
    Borzangy, Sary
    Haemmerle, Christoph H. F.
    Benic, Goran I.
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2015, 42 (11) : 1060 - 1070
  • [10] Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 1-year results of a randomized controlled clinical study
    Benic, Goran I.
    Gallucci, German O.
    Mokti, Muizzaddin
    Haemmerle, Christoph H. F.
    Weber, Hans-Peter
    Jung, Ronald E.
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2013, 40 (11) : 1052 - 1061