In this paper, a new flickermeter, designed to calculate flicker severity by using lamp illumination as its input, which complies with the lEC flickermeter for the analysis of flicker in the electricity system caused by iron and steel (I&S) plants, is described. According to the lEC Standard 61000-4-15, flicker is calculated from the voltage and based on the assumption that this voltage feeds an incandescent lamp. In this research work, a system measuring illumination of the lamps has been developed and the illumination of three different types of bulbs, incandescent lamp, compact fluorescent lamp (CFL) and light emitting diode (LED) lamp with the same input voltage, has been investigated. Based on the results, lEC flickermeter algorithm, which is designed based on the incandescent lamp assumption, has been updated to compute flicker severity for any kind of lamp and a new illumination-based flickermeter based on the lEC Standard has been developed. The measurement accuracy of the developed flickermeter has been tested and verified with the test signals recommended in the lEC Standard using actual lamp illumination inputs. Then the developed system has been used to measure the flicker severities of the incandescent lamp, CFL and LED lamp driven by a point of common coupling voltage supplying an I&S plant operating electric arc furnace plants reduced to 230V level. The results have shown that although the flicker severity limits are exceeded when an incandescent lamp is used, with the CFL limits are still exceeded but much lower flicker severity is obtained and the flicker severity computed from the illumination of the LED lamp is much below the limits.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Statistic characteristic estimations of harmonic and flicker on electric arc furnace feeders
    Chen, Ming-Tang
    Lu, Chen-Wen
    [J]. 2006 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS, VOLS 1 AND 2, 2006, : 998 - 1002
  • [12] Study of Voltage Flicker Mitigation Using Emulated Electric Arc Furnace
    Bejvl, Martin
    Simek, Petr
    Cernan, Martin
    Valouch, Viktor
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (07) : 8634 - 8644
  • [13] Assess of the Flicker Caused by Electric Arc Furnace Using Simulation Method
    Wang Yufei
    Hua Xue
    Yu Xiao
    [J]. EMERGING RESEARCH IN ARTIFICIAL INTELLIGENCE AND COMPUTATIONAL INTELLIGENCE, 2011, 237 : 128 - +
  • [14] Optimal Capacity of SVC to Compensate Flicker induced by Electric Arc Furnace
    Kim, Gildong
    Lee, Hanmin
    [J]. 2009 INTERNATIONAL CONFERENCE ON INFORMATION AND MULTIMEDIA TECHNOLOGY, PROCEEDINGS, 2009, : 43 - 46
  • [15] A microcomputer-based instrumentation system for voltage flicker measurement of an electric arc furnace feeder
    Chen, MT
    Lu, CW
    Huang, CL
    [J]. ICEMI '97 - CONFERENCE PROCEEDINGS: THIRD INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, 1997, : 307 - 310
  • [16] An Improved Nonlinear STATCOM Control for Electric Arc Furnace Voltage Flicker Mitigation
    Yazdani, Atousa
    Crow, Mariesa L.
    Guo, J.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (04) : 2284 - 2290
  • [17] Mitigation of Electric Arc Furnace voltage flicker using static synchronous compensator
    Wang, Y. F.
    Jiang, J. G.
    Ge, L. S.
    Yang, X. J.
    [J]. IPEMC 2006: CES/IEEE 5TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2006, : 1463 - +
  • [18] Study of the Flicker Phenomenon Induced in the Electric Arc Furnace of the Steel Factory in Tunisia
    University Of Ha'il, College Of Computer Science And Engineering, Department Of Computer Science And Engineering, Hail
    55476, Saudi Arabia
    不详
    42351, Saudi Arabia
    不详
    1054, Tunisia
    不详
    1008, Tunisia
    [J]. IEEE Access, (174850-174858): : 174850 - 174858
  • [19] Electric arc furnace power quality analysis based on a stochastic arc model
    Grabowski, Dariusz
    Walczak, Janusz
    Klimas, Maciej
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2018 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2018,
  • [20] On the Use of Flickermeter and DFT Based Techniques for the Assessment of Light Flicker and Interharmonic Distortion Produced by Arc Furnaces
    Langella, Roberto
    Testa, Alfredo
    [J]. 2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 2546 - 2552