Time-of-flight secondary ion mass spectrometry analysis of conformational changes in adsorbed protein films

被引:102
|
作者
Xia, N
May, CJ
McArthur, SL
Castner, DG
机构
[1] Univ Washington, Dept Chem Engn, Natl ESCA & Surface Anal Ctr Biomed Problems, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, Natl ESCA & Surface Anal Ctr Biomed Problems, Seattle, WA 98195 USA
[3] Yale Univ, Dept Biomed Engn, New Haven, CT 06520 USA
关键词
D O I
10.1021/la020022u
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The characterization of adsorbed protein films with ultrahigh vacuum (UHV) surface analysis techniques requires dehydration of the samples, which can cause significant alterations in protein conformation. Trehalose coating was used in this study to inhibit these conformational changes from occurring when preparing samples for analysis in UHV. Surface plasmon resonance (SPR) analysis showed that air-dried films of trehalose-stabilized antiferritin and anti-IgM both retained a significant proportion of their hydrated antigen binding activity. In contrast, air-drying without trehalose protection resulted in the adsorbed protein films losing most of their antigen binding activity. Structural differences between trehalose-stabilized and unstabilized protein films were then analyzed with static time-of-flight secondary ion mass spectrometry (ToF-SIMS). By application of principle component analysis (PCA) to the static ToF-SIMS spectra, the biological activity difference observed in SPR was correlated to changes in protein conformation. Trehalose-protected proteins retained a greater degree of their original conformation than the unprotected proteins. This suggests coating adsorbed protein films with trehalose prior to air-drying and introduction into UHV allows ToF-SIMS to analyze adsorbed proteins in a state that is more representative of their actual structure in an aqueous environment.
引用
收藏
页码:4090 / 4097
页数:8
相关论文
共 50 条
  • [21] Application of time-of-flight secondary ion mass spectrometry to automobile paint analysis
    Lee, Y
    Han, S
    Yoon, JH
    Kim, YM
    Shon, SK
    Park, SW
    ANALYTICAL SCIENCES, 2001, 17 (06) : 757 - 761
  • [22] Time-of-flight secondary ion mass spectrometry of industrial materials
    Keller, BA
    Hug, P
    ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) : 201 - 212
  • [23] Organic microanalysis by time-of-flight secondary ion mass spectrometry
    Sjovall, Peter
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2007, 71 (15) : A944 - A944
  • [24] LIQUID SECONDARY ION TIME-OF-FLIGHT MASS-SPECTROMETRY
    OLTHOFF, JK
    HONOVICH, JP
    COTTER, RJ
    ANALYTICAL CHEMISTRY, 1987, 59 (07) : 999 - 1002
  • [25] Full Wafer Defect Analysis with Time-Of-Flight Secondary Ion Mass Spectrometry
    Schnieders, A.
    Budri, T.
    2010 IEEE/SEMI ADVANCED SEMICONDUCTOR MANUFACTURING CONFERENCE, 2010, : 158 - 161
  • [26] Introduction to time-of-flight secondary ion mass spectrometry application in chromatographic analysis
    Orinák, A
    Arlinghaus, HF
    Vering, G
    Orináková, R
    Hellweg, S
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1084 (1-2) : 113 - 118
  • [27] Organic particle analysis using time-of-flight secondary ion mass spectrometry
    Hues, SM
    MICROBEAM ANALYSIS 2000, PROCEEDINGS, 2000, (165): : 333 - 334
  • [28] Application of Time-of-Flight Secondary Ion Mass Spectrometry to Automobile Paint Analysis
    Yeonhee Lee
    Seunghee Han
    Jung-Hyeon Yoon
    Young-Man Kim
    Sung-Kun Shon
    Sung-Woo Park
    Analytical Sciences, 2001, 17 : 757 - 761
  • [29] Analysis of liposome model systems by time-of-flight secondary ion mass spectrometry
    Lovric, Jelena
    Keighron, Jacqueline D.
    Angerer, Tina B.
    Li, Xianchan
    Malmberg, Per
    Fletcher, John S.
    Ewing, Andrew G.
    SURFACE AND INTERFACE ANALYSIS, 2014, 46 : 74 - 78
  • [30] LIQUID SECONDARY ION TIME-OF-FLIGHT MASS-SPECTROMETRY
    COTTER, RJ
    ANALYTICAL CHEMISTRY, 1984, 56 (13) : 2594 - 2596