Simultaneous determination of 11 active components in two well-known traditional Chinese medicines by HPLC coupled with diode array detection for quality control

被引:38
|
作者
Yin, Lianhong [1 ]
Lu, Binan [1 ]
Qi, Yan [1 ]
Xu, Lina [1 ]
Han, Xu [1 ]
Xu, Youwei [1 ]
Peng, Jinyong [1 ]
Sun, Changkai [2 ]
机构
[1] Dalian Med Univ, Coll Pharm, Dalian 116044, Peoples R China
[2] Dalian Med Univ, Brain Dis Inst Liaoning Prov, Dalian 116044, Peoples R China
关键词
Quality control; Herbal preparation; Qinhuanghouzheng capsule; Xiaoerqingre tablet; HPLC-DAD; PERFORMANCE LIQUID-CHROMATOGRAPHY; CAPILLARY-ELECTROPHORESIS; MASS-SPECTROMETRY; PHARMACEUTICAL FORMULATIONS; QUANTITATIVE-ANALYSIS; GAS-CHROMATOGRAPHY; PHENOLIC-COMPOUNDS; COPTIDIS-RHIZOMA; QUANTIFICATION; EXTRACTION;
D O I
10.1016/j.jpba.2009.01.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and sensitive high-performance liquid chromatography coupled with diode array detection (HPLC-DAD) method was investigated for Simultaneous determination of 11 components (chlorogenic acid, coptisine, epiberberine,jatrorrhizine, berberine, palmatine, baicalin, wogonoside, baicalein. wogonin and chrysin) in Qinhuanghouzheng (QHFIZ) capsule and Xiaoerqingre (XEQR) tablet, for quality control of these two well-known traditional Chinese medicines (TCMs). The method was established using an Eclipse Plus C-18 (150mm x 4.6mm i.d., 5 mu m) column. The mobile phase comprising methanol (A) 3% phosphoric acid (13) (pH 2.0, adjusted by triethylamine) was used to elute the targets in gradient elution mode. Flow rate and detection wavelength were set at 0.8 mL/min and 270 nm, respectively. All calibration curves showed good linearity with R-2 > 0.9995. Inter- and intra-day precisions for all investigated components expressed as relative standard deviation (R.S.D.) ranged from 0.26% to 1.77%. Recoveries measured at three concentrations were in the range of 95.0-103.0% with R.S.D. <= 3%. The validated method is simple, reliable, and successfully applied to determine the contents of the selected compounds in QHHZ capsule and XEQR tablet for quality evaluation and control. The 11 main active marker compounds measured occur only in 2 or 3 plant species out of 7-10 species comprising the two TCMs. Additional procedures need to be developed for the quality control of plant materials other than Coptis chinensis Franch, Scutellaria baicalensis Georgi and Phellodendron amurense Rupr. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1101 / 1108
页数:8
相关论文
共 44 条
  • [31] Simultaneous determination of 10 components in traditional Chinese medicine Dachaihu Granule by reversed-phase-high-performance liquid chromatographic-diode array detector
    Hu, Yingfei
    Lu, Tulin
    Mao, Chunqin
    Wu, Hao
    Zhang, Xing
    Wang, J. V.
    Gu, Juanjuan
    PHARMACOGNOSY MAGAZINE, 2013, 9 (33) : 33 - 38
  • [32] Improved quality control method for Fufang Danshen preparations through simultaneous determination of phenolic acids, saponins and diterpenoid quinones by HPLC coupled with diode array and evaporative light scattering detectors
    Wei, Ying-He
    Qi, Lian-Wen
    Li, Ping
    Luo, Hou-Wei
    Yi, Ling
    Sheng, Liang-Hong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 45 (05) : 775 - 784
  • [33] SIMULTANEOUS DETERMINATION OF TEN ACTIVE COMPONENTS IN CHINESE MEDICINE "HUANG-LIAN-SHANG-QING" TABLETS BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY COUPLED WITH PHOTODIODE ARRAY DETECTION
    Han, Xu
    Yin, Lianhong
    Xu, Lina
    Wang, Xiuying
    Peng, Jinyong
    ANALYTICAL LETTERS, 2010, 43 (04) : 545 - 556
  • [34] Simultaneous Determination of 5 Flavonoids and 7 Saponins for Quality Control of Traditional Chinese Medicine Preparation Xinnaoshutong Capsule Using HPLC-VWD-ELSD
    Li, Jin
    Bai, Yang
    Zhang, Peng
    He, Jun
    Cao, Jun
    An, Mingrui
    Hu, Li-min
    Gao, Xiu-mei
    Chang, Yan-xu
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2017, 2017
  • [35] Quality control of cytostatic drug preparations—comparison of workflow and performance of Raman/UV and high-performance liquid chromatography coupled with diode array detection (HPLC-DAD)
    Lars M. H. Reinders
    Martin D. Klassen
    Claudia vom Eyser
    Thorsten Teutenberg
    Martin Jaeger
    Torsten C. Schmidt
    Jochen Tuerk
    Analytical and Bioanalytical Chemistry, 2021, 413 : 2587 - 2596
  • [36] Simultaneous Determination of Multi-active Components in Calculus Bovis for Quality Control by High Performance Liquid Chromatography-Evaporative Light Scattering Detection
    Liu Wei
    Jin Cheng
    Kong Wei-Jun
    Wang Hai-tao
    Gong Qian-Feng
    Xiao Xiao-He
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (04) : 522 - 526
  • [37] Matrix solid-phase dispersion extraction followed by HPLC-diode array detection method for the determination of major constituents in a traditional Chinese medicine Folium isatidis (Da-qing-ye)
    Zhang, Qi
    Hong, Bo
    Zheng, Lihong
    Wang, Xiuhua
    Cai, Defu
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (18) : 2453 - 2459
  • [38] Quality control of cytostatic drug preparations-comparison of workflow and performance of Raman/UV and high-performance liquid chromatography coupled with diode array detection (HPLC-DAD)
    Reinders, Lars M. H.
    Klassen, Martin D.
    vom Eyser, Claudia
    Teutenberg, Thorsten
    Jaeger, Martin
    Schmidt, Torsten C.
    Tuerk, Jochen
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (09) : 2587 - 2596
  • [39] Simultaneous determination of five bioactive constituents in the traditional chinese medicinal preparation refined Xue-Fu-Zhu-Yu-Tang by high-performance liquid chromatography with diode-array UV detection
    Luan, LJ
    Mi, SY
    Hu, L
    Cheng, YY
    JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 61 (02) : 139 - 146
  • [40] Simultaneous determination of five bioactive constituents in the traditional Chinese medicinal preparation refined xue-fu-zhu-yu-tang by high-performance liquid chromatography with diode-array UV detection
    Lian-jun Luan
    Song-yuan Mi
    Liu Hu
    Yi-yu Cheng