Simultaneous determination of 11 active components in two well-known traditional Chinese medicines by HPLC coupled with diode array detection for quality control

被引:38
|
作者
Yin, Lianhong [1 ]
Lu, Binan [1 ]
Qi, Yan [1 ]
Xu, Lina [1 ]
Han, Xu [1 ]
Xu, Youwei [1 ]
Peng, Jinyong [1 ]
Sun, Changkai [2 ]
机构
[1] Dalian Med Univ, Coll Pharm, Dalian 116044, Peoples R China
[2] Dalian Med Univ, Brain Dis Inst Liaoning Prov, Dalian 116044, Peoples R China
关键词
Quality control; Herbal preparation; Qinhuanghouzheng capsule; Xiaoerqingre tablet; HPLC-DAD; PERFORMANCE LIQUID-CHROMATOGRAPHY; CAPILLARY-ELECTROPHORESIS; MASS-SPECTROMETRY; PHARMACEUTICAL FORMULATIONS; QUANTITATIVE-ANALYSIS; GAS-CHROMATOGRAPHY; PHENOLIC-COMPOUNDS; COPTIDIS-RHIZOMA; QUANTIFICATION; EXTRACTION;
D O I
10.1016/j.jpba.2009.01.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and sensitive high-performance liquid chromatography coupled with diode array detection (HPLC-DAD) method was investigated for Simultaneous determination of 11 components (chlorogenic acid, coptisine, epiberberine,jatrorrhizine, berberine, palmatine, baicalin, wogonoside, baicalein. wogonin and chrysin) in Qinhuanghouzheng (QHFIZ) capsule and Xiaoerqingre (XEQR) tablet, for quality control of these two well-known traditional Chinese medicines (TCMs). The method was established using an Eclipse Plus C-18 (150mm x 4.6mm i.d., 5 mu m) column. The mobile phase comprising methanol (A) 3% phosphoric acid (13) (pH 2.0, adjusted by triethylamine) was used to elute the targets in gradient elution mode. Flow rate and detection wavelength were set at 0.8 mL/min and 270 nm, respectively. All calibration curves showed good linearity with R-2 > 0.9995. Inter- and intra-day precisions for all investigated components expressed as relative standard deviation (R.S.D.) ranged from 0.26% to 1.77%. Recoveries measured at three concentrations were in the range of 95.0-103.0% with R.S.D. <= 3%. The validated method is simple, reliable, and successfully applied to determine the contents of the selected compounds in QHHZ capsule and XEQR tablet for quality evaluation and control. The 11 main active marker compounds measured occur only in 2 or 3 plant species out of 7-10 species comprising the two TCMs. Additional procedures need to be developed for the quality control of plant materials other than Coptis chinensis Franch, Scutellaria baicalensis Georgi and Phellodendron amurense Rupr. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1101 / 1108
页数:8
相关论文
共 44 条
  • [21] Simultaneous determination of ferulic acid, hesperidin, 6-gingerol and glycyrrhizin in Insampaedok-san by HPLC coupled with diode array detection
    Weon, Jin Bae
    Ma, Jin Yeul
    Yang, Hye Jin
    Ma, Choong Je
    JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 67 (12) : 955 - 959
  • [22] Simultaneous determination of ferulic acid, hesperidin, 6-gingerol and glycyrrhizin in Insampaedok-san by HPLC coupled with diode array detection
    Jin Bae Weon
    Jin Yeul Ma
    Hye Jin Yang
    Choong Je Ma
    Journal of Analytical Chemistry, 2012, 67 : 955 - 959
  • [23] Simultaneous Determination of Eight Active Components in the Traditional Chinese Medicine Dan Deng Tong Nao Capsules by HPLC-MS/MS
    Wu, Baohua
    Zhang, Xingguo
    Hong, Dongsheng
    Ma, Kuifen
    Jiang, Saiping
    PLANTA MEDICA, 2014, 80 (06) : 517 - 522
  • [24] Simultaneous Determination of Nine Active Components in Traditional Chinese Medicine 'Xue-Fu-Zhu-Yu' Capsule by HPLC-ELSD
    Gao, Ying
    Gao, Wenyuan
    Guo, Peng
    Li, Fengge
    Ma, Chaoyi
    Man, Shuli
    Hu, Jing
    LATIN AMERICAN JOURNAL OF PHARMACY, 2011, 30 (02): : 281 - 288
  • [25] Simultaneous determination of five marker compounds in Xuanfu Daizhe Tang by high-performance liquid chromatography coupled with diode array detection for quality control
    Qin, Kunming
    Wang, Bin
    Cai, Hao
    Li, Weidong
    Yao, Zhongqing
    Zhang, Xingde
    Lu, Tulin
    Cai, Baochang
    PHARMACOGNOSY MAGAZINE, 2012, 8 (32) : 250 - 255
  • [26] Simultaneous Determination of Five Major Biologically Active Ingredients in Different Parts of Gardenia jasminoides Fruits by HPLC with Diode-Array Detection
    Mei-Lian He
    Xiao-Wei Cheng
    Jia-Kuan Chen
    Tong-Shui Zhou
    Chromatographia, 2006, 64 : 713 - 717
  • [27] Simultaneous determination of five major biologically active ingredients in different parts of Gardenia jasminoides fruits by HPLC with diode-array detection
    He, Mei-Lian
    Cheng, Xiao-Wei
    Chen, Jia-Kuan
    Zhou, Tong-Shui
    CHROMATOGRAPHIA, 2006, 64 (11-12) : 713 - 717
  • [28] Determination of fifteen illegal colorants in traditional Chinese medicines by two hydrophobic DES-based microextraction methods coupled with an HPLC-DAD
    Peng, Jiaqing
    Hassan, Farhia Abdulnur
    Wu, Jianhong
    Xiong, Chaomei
    TALANTA, 2024, 277
  • [29] Simultaneous determination of seven active components in three kinds of Fufang Danshen preparations by high performance liquid chromatography with diode array detection
    Wei Yingjie
    Li Ping
    Li Songlin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (12) : 1702 - 1706
  • [30] Development of a Special Two-Dimensional Fingerprint for the Quality Evaluation of Euonymus Alatu by HPLC with Diode Array Detector Coupled with Chemiluminescence Detection
    Ding, Xiao-Ping
    Wang, Xin-Tang
    Chen, Lin-Lin
    Xu, Tian
    Yu, Bo-Yang
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 82 - 93