Detection and quantification of exhaled volatile organic compounds in mechanically ventilated patients - comparison of two sampling methods

被引:11
|
作者
van Oort, Pouline M. P. [1 ]
White, Iain R. [2 ,3 ]
Ahmed, Waqar [2 ,4 ,5 ]
Johnson, Craig [2 ]
Bannard-Smith, Jonathan [6 ]
Felton, Timothy [4 ,5 ,6 ]
Bos, Lieuwe D. [1 ]
Goodacre, Royston [7 ]
Dark, Paul [4 ,5 ,6 ]
Fowler, Stephen J. [4 ,5 ,6 ]
机构
[1] Amsterdam UMC Locat Acad Med Ctr AMC, Dept Intens Care, Amsterdam, Netherlands
[2] Univ Manchester, Manchester Inst Biotechnol, Manchester, Lancs, England
[3] Univ Nova Gorica, Lab Environm & Life Sci, Nova Gorica, Slovenia
[4] Univ Manchester, Fac Biol Med & Hlth, Sch Biol Sci, Div Infect Immun & Resp Med, Manchester, Lancs, England
[5] Univ Manchester, NIHR Manchester Biomed Res Ctr, Manchester, Lancs, England
[6] Manchester Univ Hosp NHS Fdn Trust, Manchester Acad Hlth Sci Ctr, Manchester, Lancs, England
[7] Univ Liverpool, Inst Integrat Biol, Dept Biochem, Liverpool, Merseyside, England
基金
美国国家卫生研究院;
关键词
CHROMATOGRAPHY-MASS-SPECTROMETRY; RETENTION INDEXES; BREATH ANALYSIS; CONSTITUENTS; METABOLOMICS; KOVATS; L;
D O I
10.1039/c9an01134j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Exhaled breath analysis is a promising new diagnostic tool, but currently no standardised method for sampling is available in mechanically ventilated patients. We compared two breath sampling methods, first using an artificial ventilator circuit, then in "real life" in mechanically ventilated patients on the intensive care unit. In the laboratory circuit, a 24-component synthetic-breath volatile organic compound (VOC) mixture was injected into the system as air was sampled: (A) through a port on the exhalation limb of the circuit and (B) through a closed endo-bronchial suction catheter. Sorbent tubes were used to collect samples for analysis by thermal desorption-gas chromatography-mass spectrometry. Realistic mechanical ventilation rates and breath pressure-volume loops were established and method detection limits (MDLs) were calculated for all VOCs. Higher yields of VOCs were retrieved using the closed suction catheter; however, for several VOCs MDLs were compromised due to the background signal associated with plastic and rubber components in the catheters. Different brands of suction catheter were compared. Exhaled VOC data from 40 patient samples collected at two sites were then used to calculate the proportion of data analysed above the MDL. The relative performance of the two methods differed depending on the VOC under study and both methods showed sensitivity towards different exhaled VOCs. Furthermore, method performance differed depending on recruitment site, as the centres were equipped with different brands of respiratory equipment, an important consideration for the design of multicentre studies investigating exhaled VOCs in mechanically ventilated patients.
引用
收藏
页码:222 / 231
页数:10
相关论文
共 50 条
  • [11] Detection of volatile organic compounds (VOCs) from exhaled breath as noninvasive methods for cancer diagnosis
    Xiaohua Sun
    Kang Shao
    Tie Wang
    Analytical and Bioanalytical Chemistry, 2016, 408 : 2759 - 2780
  • [12] Volatile organic compounds: Comparison of two sample collection and presentation methods
    Liikala, TL
    Olsen, KB
    Teel, SS
    Lanigan, DC
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (12) : 3441 - 3447
  • [13] Exhaled volatile organic compounds identify patients with colorectal cancer
    Altomare, D. F.
    Di Lena, M.
    Porcelli, F.
    Trizio, L.
    Travaglio, E.
    Tutino, M.
    Dragonieri, S.
    Memeo, V.
    de Gennaro, G.
    BRITISH JOURNAL OF SURGERY, 2013, 100 (01) : 144 - 151
  • [14] Design of Breath Sampling Device and Procedure for Volatile Organic Compounds and Exhaled Breath Condensate
    Xiong, Hangming
    Sun, Jiaying
    Xue, Yingying
    Yu, Weijei
    Zhou, Yong
    Wan, Hao
    Wang, Ping
    2022 IEEE INTERNATIONAL SYMPOSIUM ON OLFACTION AND ELECTRONIC NOSE (ISOEN 2022), 2022,
  • [15] Volatile Organic Compounds Concentrations In The Exhaled Breath Of Ventilated Icu-Patients Are Different Between Patients With Pneumonia, Colonized Airways And Controls
    Bos, L. D. J.
    Leopold, J. -H.
    Brinkman, P.
    Weda, H.
    Wang, Y.
    Knobel, H.
    Nijsen, T.
    Vink, T.
    Sterk, P. J.
    Schultz, M. J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [16] Machine learning methods on exhaled volatile organic compounds for distinguishing COPD patients from healthy controls
    Phillips, Chris O.
    Syed, Yasir
    Mac Parthalain, Neil
    Zwiggelaar, Reyer
    Claypole, Tim C.
    Lewis, Keir E.
    JOURNAL OF BREATH RESEARCH, 2012, 6 (03)
  • [17] Volatile organic compounds in the exhaled breath of young patients with cystic fibrosis
    Barker, M
    Hengst, M
    Schmid, J
    Buers, HJ
    Mittermaier, B
    Klemp, D
    Koppman, R
    EUROPEAN RESPIRATORY JOURNAL, 2006, 27 (05) : 929 - 936
  • [18] Volatile Organic Compounds (VOC) in Exhaled Breath in Patients With Lung Cancer
    Jareno, Javier
    Angeles Munoz, Maria
    Wagner, Carolin
    Civera, Concepcion
    Callol, Luis
    CHEST, 2014, 145 (03)
  • [19] Comparison of sampling bags for the analysis of volatile organic compounds in breath
    Ghimenti, S.
    Lomonaco, T.
    Bellagambi, F. G.
    Tabucchi, S.
    Onor, M.
    Trivella, M. G.
    Ceccarini, A.
    Fuoco, R.
    Di Francesco, F.
    JOURNAL OF BREATH RESEARCH, 2015, 9 (04)
  • [20] Exhaled Volatile Organic Compounds for Identifying Patients With Chronic Pulmonary Aspergillosis
    Li, Zheng-Tu
    Zeng, Pei-Ying
    Chen, Zhao-Ming
    Guan, Wei-Jie
    Wang, Tong
    Lin, Ye
    Li, Shao-Qiang
    Zhang, Zhi-Juan
    Zhan, Yang-Qing
    Wang, Ming-Die
    Tan, Guo-Bin
    Li, Xue
    Ye, Feng
    FRONTIERS IN MEDICINE, 2021, 8