Detection and quantification of exhaled volatile organic compounds in mechanically ventilated patients - comparison of two sampling methods

被引:11
|
作者
van Oort, Pouline M. P. [1 ]
White, Iain R. [2 ,3 ]
Ahmed, Waqar [2 ,4 ,5 ]
Johnson, Craig [2 ]
Bannard-Smith, Jonathan [6 ]
Felton, Timothy [4 ,5 ,6 ]
Bos, Lieuwe D. [1 ]
Goodacre, Royston [7 ]
Dark, Paul [4 ,5 ,6 ]
Fowler, Stephen J. [4 ,5 ,6 ]
机构
[1] Amsterdam UMC Locat Acad Med Ctr AMC, Dept Intens Care, Amsterdam, Netherlands
[2] Univ Manchester, Manchester Inst Biotechnol, Manchester, Lancs, England
[3] Univ Nova Gorica, Lab Environm & Life Sci, Nova Gorica, Slovenia
[4] Univ Manchester, Fac Biol Med & Hlth, Sch Biol Sci, Div Infect Immun & Resp Med, Manchester, Lancs, England
[5] Univ Manchester, NIHR Manchester Biomed Res Ctr, Manchester, Lancs, England
[6] Manchester Univ Hosp NHS Fdn Trust, Manchester Acad Hlth Sci Ctr, Manchester, Lancs, England
[7] Univ Liverpool, Inst Integrat Biol, Dept Biochem, Liverpool, Merseyside, England
基金
美国国家卫生研究院;
关键词
CHROMATOGRAPHY-MASS-SPECTROMETRY; RETENTION INDEXES; BREATH ANALYSIS; CONSTITUENTS; METABOLOMICS; KOVATS; L;
D O I
10.1039/c9an01134j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Exhaled breath analysis is a promising new diagnostic tool, but currently no standardised method for sampling is available in mechanically ventilated patients. We compared two breath sampling methods, first using an artificial ventilator circuit, then in "real life" in mechanically ventilated patients on the intensive care unit. In the laboratory circuit, a 24-component synthetic-breath volatile organic compound (VOC) mixture was injected into the system as air was sampled: (A) through a port on the exhalation limb of the circuit and (B) through a closed endo-bronchial suction catheter. Sorbent tubes were used to collect samples for analysis by thermal desorption-gas chromatography-mass spectrometry. Realistic mechanical ventilation rates and breath pressure-volume loops were established and method detection limits (MDLs) were calculated for all VOCs. Higher yields of VOCs were retrieved using the closed suction catheter; however, for several VOCs MDLs were compromised due to the background signal associated with plastic and rubber components in the catheters. Different brands of suction catheter were compared. Exhaled VOC data from 40 patient samples collected at two sites were then used to calculate the proportion of data analysed above the MDL. The relative performance of the two methods differed depending on the VOC under study and both methods showed sensitivity towards different exhaled VOCs. Furthermore, method performance differed depending on recruitment site, as the centres were equipped with different brands of respiratory equipment, an important consideration for the design of multicentre studies investigating exhaled VOCs in mechanically ventilated patients.
引用
收藏
页码:222 / 231
页数:10
相关论文
共 50 条
  • [1] Influence of ventilatory parameters on the concentration of exhaled volatile organic compounds in mechanically ventilated patients
    Romano, Andrea
    Fehervari, Matyas
    Boshier, Piers R.
    ANALYST, 2023, 148 (17) : 4020 - 4029
  • [2] Methods for Detection of Volatile Organic Compounds in Human Exhaled Breath
    Zhang Chen
    Zhao Meiping
    PROGRESS IN CHEMISTRY, 2010, 22 (01) : 140 - 147
  • [3] Field detection and quantification of volatile organic compounds
    Hobson, Stephen T.
    Cemalovic, Sabina
    Mlsna, Debra
    Mlsna, Todd E.
    Patel, Sanjay V.
    Thieme, Janet
    Tolley, William
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 238
  • [4] Comparison of Effects on Volatile and Semi-Volatile Organic Compounds in Water by Different Sampling Methods
    Liu Jingtao
    Sun Jichao
    Wang Jincui
    Huang Guanxing
    Jing Jihong
    Xiang Xiaoping
    Chen Xi
    Zhang Yuxi
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 2, PROCEEDINGS, 2009, : 480 - 483
  • [5] SAMPLING AND ANALYSIS OF ALVEOLAR EXHALED BREATH CONDENSATE IN MECHANICALLY VENTILATED PATIENTS: A FEASIBILITY STUDY
    Vaschetto, R.
    Goldoni, M.
    Cancelliere, L.
    Pulvirenti, S.
    Fazzini, U.
    Costagliola, R.
    Capuzzi, F.
    Longhini, F.
    Cammarota, G.
    Della Corte, F.
    Mutti, A.
    Corradi, M.
    Navalesi, P.
    INTENSIVE CARE MEDICINE, 2013, 39 : S490 - S490
  • [6] Sampling and analyzing alveolar exhaled breath condensate in mechanically ventilated patients: a feasibility study
    Vaschetto, Rosanna
    Corradi, Massimo
    Goldoni, Matteo
    Cancelliere, Laura
    Pulvirenti, Simone
    Fazzini, Ugo
    Capuzzi, Fabio
    Longhini, Federico
    Mutti, Antonio
    Della Corte, Francesco
    Navalesi, Paolo
    JOURNAL OF BREATH RESEARCH, 2015, 9 (04)
  • [7] Comparison of sampling methods for the determination of volatile organic compounds in consumer aerosol sprays
    Sungyo Jung
    Myoungho Lee
    Geonho Do
    Boowook kim
    Kiyoung Lee
    Kyung-Duk Zoh
    Chungsik Yoon
    Scientific Reports, 13
  • [8] Comparison of sampling methods for the determination of volatile organic compounds in consumer aerosol sprays
    Jung, Sungyo
    Lee, Myoungho
    Do, Geonho
    Kim, Boowook
    Lee, Kiyoung
    Zoh, Kyung-Duk
    Yoon, Chungsik
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [9] Exhaled Volatile Organic Compounds during Inflammation Induced by TNF-α in Ventilated Rats
    Albrecht, Frederic W.
    Maurer, Felix
    Mueller-Wirtz, Lukas M.
    Schwaiblmair, Michaela H.
    Hueppe, Tobias
    Wolf, Beate
    Sessler, Daniel, I
    Volk, Thomas
    Kreuer, Sascha
    Fink, Tobias
    METABOLITES, 2020, 10 (06) : 1 - 9
  • [10] Detection of volatile organic compounds (VOCs) from exhaled breath as noninvasive methods for cancer diagnosis
    Sun, Xiaohua
    Shao, Kang
    Wang, Tie
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (11) : 2759 - 2780