Use of a CMOS-based micro-CT system to validate a ring artifact correction algorithm on low-dose image data

被引:1
|
作者
Podgorsak, Alexander R. [1 ,2 ]
Nagesh, S. V. Setlur [2 ]
Bednarek, Daniel [2 ,3 ]
Rudin, Stephen [1 ,2 ,3 ,4 ]
Ionita, Ciprian N. [1 ,2 ]
机构
[1] SUNY Buffalo, Dept Biomed Engn, Buffalo, NY 14260 USA
[2] Toshiba Canon Stroke & Vasc Res Ctr, Buffalo, NY 14203 USA
[3] SUNY Buffalo, Dept Radiol, Buffalo, NY USA
[4] SUNY Buffalo, Dept Neurosurg, Buffalo, NY USA
关键词
Ring artifacts; micro-CT; CMOS; FLAT-FIELD CORRECTION;
D O I
10.1117/12.2292581
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The imaging of objects using high-resolution detectors coupled to CT systems may be made challenging due to the presence of ring artifacts in the reconstructed data. Not only are the artifacts qualitatilvely distracting, they reduce the SNR of the reconstructed data and may lead to a reduction in the clinical utility of the image data. To address these challenges, we introduce a multistep algorithm that greatly reduces the impact of the ring artifacts on the reconstructed data through image processing in the sinogram space. First, for a single row of detectors corresponding to one slice, we compute the mean of every detector element in the row across all projection view angles and place the reciprocal values in a vector with length equal to the number of detector elements in a row. This vector is then multiplied with each detector element value for each projection view angle, obtaining a normalized or corrected sinogram. This sinogram is subtracted from the original uncorrected sinogram of the slice to obtain a difference map, which is then blurred with a median filter along the row direction. This blurred difference map is summed back to the corrected sinogram, to obtain the final sinogram, which can be back projected to obtain an axial slice of the scanned object, with a greatly reduced presence of ring artifacts. This process is done for each detector row corresponding to each slice. The performance of this algorithm was assessed using images of a mouse femur. These images were acquired using a micro-CT system coupled to a high-resolution CMOS detector. We found that the use of this algorithm led to an increase in SNR and a more uniform line-profile, as a result of the reduction in the presence of the ring artifacts.
引用
收藏
页数:12
相关论文
共 26 条
  • [1] Algorithm-Enabled Low-Dose Micro-CT Imaging
    Han, Xiao
    Bian, Junguo
    Eaker, Diane R.
    Kline, Timothy L.
    Sidky, Emil Y.
    Ritman, Erik L.
    Pan, Xiaochuan
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (03) : 606 - 620
  • [2] Implementation of material decomposition using an EMCCD and CMOS-based micro-CT system
    Podgorsak, Alexander R.
    Nagesh, S. V. Setlur
    Bednarek, Daniel R.
    Rudin, Stephen
    Ionita, Ciprian N.
    [J]. MEDICAL IMAGING 2017: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2017, 10137
  • [3] Initial experience with a novel low-dose micro-CT system
    Stiller, W.
    Kobayashi, M.
    Koike, K.
    Stampfl, U.
    Richter, G. M.
    Semmler, W.
    Kiessling, F.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (07): : 669 - 675
  • [4] Detector shifting and deep learning based ring artifact correction method for low-dose CT
    Liu, Yuedong
    Wei, Cunfeng
    Xu, Qiong
    [J]. MEDICAL PHYSICS, 2023, 50 (07) : 4308 - 4324
  • [5] Sparse-view image reconstruction in prospectively gated micro-CT for fast and low-dose imaging
    Jonghwan Min
    Gyuseong Cho
    Seungryong Cho
    Kyoungwoo Kim
    [J]. Journal of the Korean Physical Society, 2012, 60 : 1157 - 1160
  • [6] Learning-Based Artifact Removal via Image Decomposition for Low-Dose CT Image Processing
    Cui, Xue-Ying
    Gui, Zhi-Guo
    Zhang, Quan
    Shangguan, Hong
    Wang, An-Hong
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (03) : 1860 - 1873
  • [7] Sparse-view Image Reconstruction in Prospectively Gated Micro-CT for Fast and Low-dose Imaging
    Min, Jonghwan
    Cho, Gyuseong
    Cho, Seungryong
    Kim, Kyoungwoo
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (07) : 1157 - 1160
  • [8] Low-Dose CT Denoising Algorithm Based on Image Cartoon Texture Decomposition
    Hao Chen
    Yi Liu
    Pengcheng Zhang
    Jiaqi Kang
    Zhiyuan Li
    Weiting Cheng
    Zhiguo Gui
    [J]. Circuits, Systems, and Signal Processing, 2024, 43 : 3073 - 3101
  • [9] Low-Dose CT Denoising Algorithm Based on Image Cartoon Texture Decomposition
    Chen, Hao
    Liu, Yi
    Zhang, Pengcheng
    Kang, Jiaqi
    Li, Zhiyuan
    Cheng, Weiting
    Gui, Zhiguo
    [J]. CIRCUITS SYSTEMS AND SIGNAL PROCESSING, 2024, 43 (05) : 3073 - 3101
  • [10] Tensor framelet based iterative image reconstruction algorithm for low-dose multislice helical CT
    Nam, Haewon
    Guo, Minghao
    Yu, Hengyong
    Lee, Keumsil
    Li, Ruijiang
    Han, Bin
    Xing, Lei
    Lee, Rena
    Gao, Hao
    [J]. PLOS ONE, 2019, 14 (01):