Use of a CMOS-based micro-CT system to validate a ring artifact correction algorithm on low-dose image data

被引:1
|
作者
Podgorsak, Alexander R. [1 ,2 ]
Nagesh, S. V. Setlur [2 ]
Bednarek, Daniel [2 ,3 ]
Rudin, Stephen [1 ,2 ,3 ,4 ]
Ionita, Ciprian N. [1 ,2 ]
机构
[1] SUNY Buffalo, Dept Biomed Engn, Buffalo, NY 14260 USA
[2] Toshiba Canon Stroke & Vasc Res Ctr, Buffalo, NY 14203 USA
[3] SUNY Buffalo, Dept Radiol, Buffalo, NY USA
[4] SUNY Buffalo, Dept Neurosurg, Buffalo, NY USA
关键词
Ring artifacts; micro-CT; CMOS; FLAT-FIELD CORRECTION;
D O I
10.1117/12.2292581
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The imaging of objects using high-resolution detectors coupled to CT systems may be made challenging due to the presence of ring artifacts in the reconstructed data. Not only are the artifacts qualitatilvely distracting, they reduce the SNR of the reconstructed data and may lead to a reduction in the clinical utility of the image data. To address these challenges, we introduce a multistep algorithm that greatly reduces the impact of the ring artifacts on the reconstructed data through image processing in the sinogram space. First, for a single row of detectors corresponding to one slice, we compute the mean of every detector element in the row across all projection view angles and place the reciprocal values in a vector with length equal to the number of detector elements in a row. This vector is then multiplied with each detector element value for each projection view angle, obtaining a normalized or corrected sinogram. This sinogram is subtracted from the original uncorrected sinogram of the slice to obtain a difference map, which is then blurred with a median filter along the row direction. This blurred difference map is summed back to the corrected sinogram, to obtain the final sinogram, which can be back projected to obtain an axial slice of the scanned object, with a greatly reduced presence of ring artifacts. This process is done for each detector row corresponding to each slice. The performance of this algorithm was assessed using images of a mouse femur. These images were acquired using a micro-CT system coupled to a high-resolution CMOS detector. We found that the use of this algorithm led to an increase in SNR and a more uniform line-profile, as a result of the reduction in the presence of the ring artifacts.
引用
收藏
页数:12
相关论文
共 26 条
  • [21] BAYESIAN COMPRESSED SENSING ALGORITHM FOR CONTRAST-ENHANCED LOW-DOSE CT IMAGE WITH IODINE BASED ON CARBON NANOTUBE X-RAY TUBE
    Liu, Xiaopei
    Teng, Jianfu
    Fei, Teng
    Sun, Yunshan
    [J]. ACTA MEDICA MEDITERRANEA, 2022, 38 (02): : 1257 - 1262
  • [22] Limited-angle iterative reconstruction (LAIR) as a new approach to reducing radiation dose without sacrificing image quality: Context-encoder based sinogram completion and image-quality based stopping-criteria applied to a laboratory micro-CT system
    Jin, S. C.
    Chen, J. C.
    Tu, S. H.
    Chen, Y. C.
    Hsiao, T. C.
    Liu, A.
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2018, 123 : 52 - 53
  • [23] Impact of dose reduction and the use of an advanced model-based iterative reconstruction algorithm on spectral performance of a dual-source CT system: A task-based image quality assessment
    Greffier, Joel
    Dabli, Djamel
    Hamard, Aymeric
    Akessoul, Philippe
    Belaouni, Asmaa
    Beregi, Jean-Paul
    Frandon, Julien
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (7-8) : 405 - 412
  • [24] Improving pulmonary vessel image quality with a full model-based iterative reconstruction algorithm in 80kVp low-dose chest CT for pediatric patients aged 0-6 years
    Sun, Jihang
    Zhang, Qifeng
    Hu, Di
    Duan, Xiaomin
    Peng, Yun
    [J]. ACTA RADIOLOGICA, 2015, 56 (06) : 761 - 768
  • [25] Digital subtraction angiography during transjugular intrahepatic portosystemic shunt creation or revision: data on radiation exposure and image quality obtained using a standard and a low-dose acquisition protocol in a flat-panel detector-based system
    Roberto Miraglia
    Luigi Maruzzelli
    Kelvin Cortis
    Corrado Tafaro
    Roberta Gerasia
    Carmelo Parisi
    Angelo Luca
    [J]. Abdominal Imaging, 2015, 40 : 1808 - 1812
  • [26] Digital subtraction angiography during transjugular intrahepatic portosystemic shunt creation or revision: data on radiation exposure and image quality obtained using a standard and a low-dose acquisition protocol in a flat-panel detector-based system
    Miraglia, Roberto
    Maruzzelli, Luigi
    Cortis, Kelvin
    Tafaro, Corrado
    Gerasia, Roberta
    Parisi, Carmelo
    Luca, Angelo
    [J]. ABDOMINAL IMAGING, 2015, 40 (06): : 1808 - 1812