Scatter correction for a clinical cone-beam CT system using an optimized stationary beam blocker in a single scan

被引:18
|
作者
Liang, Xiaokun [1 ,2 ]
Jiang, Yangkang [3 ,4 ]
Zhao, Wei [5 ]
Zhang, Zhicheng [1 ,2 ]
Luo, Chen [3 ,4 ]
Xiong, Jing [1 ]
Yu, Shaode [1 ,2 ]
Yang, Xiaoming [4 ]
Sun, Jihong [4 ]
Zhou, Qinxuan [4 ]
Niu, Tianye [3 ,4 ]
Xie, Yaoqin [1 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518055, Guangdong, Peoples R China
[2] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen 518055, Guangdong, Peoples R China
[3] Zhejiang Univ, Inst Translat Med, Hangzhou 310016, Zhejiang, Peoples R China
[4] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Hangzhou 310016, Zhejiang, Peoples R China
[5] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
基金
中国国家自然科学基金;
关键词
clinical cone-beam CT; scatter correction; single scan; stationary beam blocker; wobble estimation; X-RAY SCATTER; COMPUTED-TOMOGRAPHY; SHADING CORRECTION; CORRECTION ALGORITHM; NOISE-REDUCTION; PATTERN SEARCH; RADIATION; LOCALIZATION; KILOVOLTAGE; GEOMETRY;
D O I
10.1002/mp.13568
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Scatter contamination in the cone-beam CT (CBCT) leads to CT number inaccuracy, spatial nonuniformity, and loss of image contrast. In our previous work, we proposed a single scan scatter correction approach using a stationary partial beam blocker. Although the previous method works effectively on a tabletop CBCT system, it fails to achieve high image quality on a clinical CBCT system mainly due to the wobble of the LINAC gantry during scan acquisition. Due to the mechanical deformation of CBCT gantry, the wobbling effect is observed in the clinical CBCT scan, and more missing data present using the previous blocker with the uniformly distributed lead strips. Methods An optimal blocker distribution is proposed to minimize the missing data. In the objective function of the missing data, the motion of the beam blocker in each projection is estimated using the segmentation due to its high contrast in the blocked area. The scatter signals from the blocker are also estimated using an air scan with the inserted blocker. The final image is generated using the forward projection to compensate for the missing data. Results On the Catphan (c) 504 phantom, our approach reduces the average CT number error from 86 Hounsfield unit (HU) to 9 HU and improves the image contrast by a factor of 1.45 in the high-contrast rods. On a head patient, the CT number error is reduced from 97 HU to 6 HU in the soft-tissue region and the image spatial nonuniformity is decreased from 27% to 5%. Conclusions The results suggest that the proposed method is promising for clinical applications.
引用
收藏
页码:3165 / 3179
页数:15
相关论文
共 50 条
  • [41] Scatter Reduction and Correction for Dual-Source Cone-Beam CT Using Prepatient Grids
    Ren, Lei
    Chen, Yingxuan
    Zhang, You
    Giles, William
    Jin, Jianyue
    Yin, Fang-Fang
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (03) : 416 - 427
  • [42] Robust scatter correction method for cone-beam CT using an interlacing-slit plate
    黄魁东
    徐哲
    张定华
    张华
    时稳龙
    Chinese Physics C, 2016, (06) : 99 - 106
  • [43] Scatter correction of cone-beam CT using a deep residual convolution neural network (DRCNN)
    Jiang, Yangkang
    Yang, Chunlin
    Yang, Pengfei
    Hu, Xi
    Luo, Chen
    Xue, Yi
    Xu, Lei
    Hu, Xiuhua
    Zhang, Luhan
    Wang, Jing
    Sheng, Ke
    Niu, Tianye
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (14):
  • [44] Robust scatter correction method for cone-beam CT using an interlacing-slit plate
    Huang, Kui-Dong
    Xu, Zhe
    Zhang, Ding-Hua
    Zhang, Hua
    Shi, Wen-Long
    CHINESE PHYSICS C, 2016, 40 (06) : 99 - 106
  • [45] Robust scatter correction method for cone-beam CT using an interlacing-slit plate
    黄魁东
    徐哲
    张定华
    张华
    时稳龙
    Chinese Physics C, 2016, 40 (06) : 99 - 106
  • [46] Improved Primary Modulation Method for Scatter Correction in Cone-Beam CT Using Local Filtration
    Zhu, L.
    MEDICAL PHYSICS, 2017, 44 (06) : 3283 - 3284
  • [47] Clinical Validations of Shading Correction for Cone-Beam CT Using Planning CT as a Prior
    Tsui, T.
    Wei, J.
    Zhu, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3219 - 3219
  • [48] Parameterization of Scatter Dependent Artifacts in Cone-Beam CT
    Mail, N.
    Moseley, D.
    Jaffray, D.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [49] Compensators for management of dose and scatter in cone-beam CT
    Graham, S.
    Moseley, D.
    Siewerdsen, J.
    Jaffray, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 1998 - 1999
  • [50] A Binary Moving Blocker-Based Scatter Correction Technique for Cone-Beam CT with Width-Truncated Projections
    Lee, H.
    Fahimian, B.
    Xing, L.
    MEDICAL PHYSICS, 2012, 39 (06) : 3892 - 3892