Scatter correction for a clinical cone-beam CT system using an optimized stationary beam blocker in a single scan

被引:18
|
作者
Liang, Xiaokun [1 ,2 ]
Jiang, Yangkang [3 ,4 ]
Zhao, Wei [5 ]
Zhang, Zhicheng [1 ,2 ]
Luo, Chen [3 ,4 ]
Xiong, Jing [1 ]
Yu, Shaode [1 ,2 ]
Yang, Xiaoming [4 ]
Sun, Jihong [4 ]
Zhou, Qinxuan [4 ]
Niu, Tianye [3 ,4 ]
Xie, Yaoqin [1 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518055, Guangdong, Peoples R China
[2] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen 518055, Guangdong, Peoples R China
[3] Zhejiang Univ, Inst Translat Med, Hangzhou 310016, Zhejiang, Peoples R China
[4] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Hangzhou 310016, Zhejiang, Peoples R China
[5] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
基金
中国国家自然科学基金;
关键词
clinical cone-beam CT; scatter correction; single scan; stationary beam blocker; wobble estimation; X-RAY SCATTER; COMPUTED-TOMOGRAPHY; SHADING CORRECTION; CORRECTION ALGORITHM; NOISE-REDUCTION; PATTERN SEARCH; RADIATION; LOCALIZATION; KILOVOLTAGE; GEOMETRY;
D O I
10.1002/mp.13568
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Scatter contamination in the cone-beam CT (CBCT) leads to CT number inaccuracy, spatial nonuniformity, and loss of image contrast. In our previous work, we proposed a single scan scatter correction approach using a stationary partial beam blocker. Although the previous method works effectively on a tabletop CBCT system, it fails to achieve high image quality on a clinical CBCT system mainly due to the wobble of the LINAC gantry during scan acquisition. Due to the mechanical deformation of CBCT gantry, the wobbling effect is observed in the clinical CBCT scan, and more missing data present using the previous blocker with the uniformly distributed lead strips. Methods An optimal blocker distribution is proposed to minimize the missing data. In the objective function of the missing data, the motion of the beam blocker in each projection is estimated using the segmentation due to its high contrast in the blocked area. The scatter signals from the blocker are also estimated using an air scan with the inserted blocker. The final image is generated using the forward projection to compensate for the missing data. Results On the Catphan (c) 504 phantom, our approach reduces the average CT number error from 86 Hounsfield unit (HU) to 9 HU and improves the image contrast by a factor of 1.45 in the high-contrast rods. On a head patient, the CT number error is reduced from 97 HU to 6 HU in the soft-tissue region and the image spatial nonuniformity is decreased from 27% to 5%. Conclusions The results suggest that the proposed method is promising for clinical applications.
引用
收藏
页码:3165 / 3179
页数:15
相关论文
共 50 条
  • [21] Correction of veiling glare and scatter in cone-beam CT
    Baba, R
    Ueda, K
    Takagi, H
    RADIOLOGY, 1999, 213P : 453 - 453
  • [22] A Hybrid Scatter Correction Method for Cone-Beam CT
    Zhang, Feng
    Yan, Bin
    Li, Jianxin
    Li, Lei
    Jia, Pengxiang
    Hu, Guoen
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 23 - 27
  • [23] Noise suppression in scatter correction for cone-beam CT
    Zhu, Lei
    Wang, Jing
    Xing, Lei
    MEDICAL PHYSICS, 2009, 36 (03) : 741 - 752
  • [24] Scatter correction for cone-beam CT in radiation therapy
    Zhu, Lei
    Xie, Yaoqin
    Wang, Jing
    Xing, Lei
    MEDICAL PHYSICS, 2009, 36 (06) : 2258 - 2268
  • [25] Noise Suppression in Scatter Correction for Cone-Beam CT
    Xing, L.
    Wang, J.
    Zhu, L.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [26] Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information
    Lee, Ho
    Xing, Lei
    Lee, Rena
    Fahimian, Benjamin P.
    MEDICAL PHYSICS, 2012, 39 (05) : 2386 - 2395
  • [27] Scatter correction method for cone-beam CT based on interlacing-slit scan
    黄魁东
    张华
    史仪凯
    张亮
    徐哲
    Chinese Physics B, 2014, (09) : 519 - 525
  • [28] A rotating beam-blocker method for cone beam CT scatter correction
    Cui, Hehe
    Zhan, Haolin
    Yuan, Xiaogang
    Yang, Yidong
    MEDICAL PHYSICS, 2024, : 7320 - 7331
  • [29] Scatter correction method for cone-beam CT based on interlacing-slit scan
    Huang Kui-Dong
    Zhang Hua
    Shi Yi-Kai
    Zhang Liang
    Xu Zhe
    CHINESE PHYSICS B, 2014, 23 (09)
  • [30] Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction
    Min, Jonghwan
    Pua, Rizza
    Kim, Insoo
    Han, Bumsoo
    Cho, Seungryong
    MEDICAL PHYSICS, 2015, 42 (11) : 6625 - 6640