Scatter correction for a clinical cone-beam CT system using an optimized stationary beam blocker in a single scan

被引:18
|
作者
Liang, Xiaokun [1 ,2 ]
Jiang, Yangkang [3 ,4 ]
Zhao, Wei [5 ]
Zhang, Zhicheng [1 ,2 ]
Luo, Chen [3 ,4 ]
Xiong, Jing [1 ]
Yu, Shaode [1 ,2 ]
Yang, Xiaoming [4 ]
Sun, Jihong [4 ]
Zhou, Qinxuan [4 ]
Niu, Tianye [3 ,4 ]
Xie, Yaoqin [1 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518055, Guangdong, Peoples R China
[2] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen 518055, Guangdong, Peoples R China
[3] Zhejiang Univ, Inst Translat Med, Hangzhou 310016, Zhejiang, Peoples R China
[4] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Hangzhou 310016, Zhejiang, Peoples R China
[5] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
基金
中国国家自然科学基金;
关键词
clinical cone-beam CT; scatter correction; single scan; stationary beam blocker; wobble estimation; X-RAY SCATTER; COMPUTED-TOMOGRAPHY; SHADING CORRECTION; CORRECTION ALGORITHM; NOISE-REDUCTION; PATTERN SEARCH; RADIATION; LOCALIZATION; KILOVOLTAGE; GEOMETRY;
D O I
10.1002/mp.13568
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Scatter contamination in the cone-beam CT (CBCT) leads to CT number inaccuracy, spatial nonuniformity, and loss of image contrast. In our previous work, we proposed a single scan scatter correction approach using a stationary partial beam blocker. Although the previous method works effectively on a tabletop CBCT system, it fails to achieve high image quality on a clinical CBCT system mainly due to the wobble of the LINAC gantry during scan acquisition. Due to the mechanical deformation of CBCT gantry, the wobbling effect is observed in the clinical CBCT scan, and more missing data present using the previous blocker with the uniformly distributed lead strips. Methods An optimal blocker distribution is proposed to minimize the missing data. In the objective function of the missing data, the motion of the beam blocker in each projection is estimated using the segmentation due to its high contrast in the blocked area. The scatter signals from the blocker are also estimated using an air scan with the inserted blocker. The final image is generated using the forward projection to compensate for the missing data. Results On the Catphan (c) 504 phantom, our approach reduces the average CT number error from 86 Hounsfield unit (HU) to 9 HU and improves the image contrast by a factor of 1.45 in the high-contrast rods. On a head patient, the CT number error is reduced from 97 HU to 6 HU in the soft-tissue region and the image spatial nonuniformity is decreased from 27% to 5%. Conclusions The results suggest that the proposed method is promising for clinical applications.
引用
下载
收藏
页码:3165 / 3179
页数:15
相关论文
共 50 条
  • [1] Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker in a Single Scan
    Liang, X.
    Luo, C.
    Zhang, Z.
    Xie, Y.
    Niu, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E170 - E170
  • [2] Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker with a Single Scan
    Liang, X.
    Gong, S.
    Zhou, Q.
    Zhang, Z.
    Xie, Y.
    Niu, T.
    MEDICAL PHYSICS, 2016, 43 (06) : 3457 - 3457
  • [3] Single-scan scatter correction for cone-beam CT using a stationary beam blocker: a preliminary study
    Niu, Tianye
    Zhu, Lei
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [4] Low-Dose and Scatter-Free Cone-Beam CT Imaging Using a Stationary Beam Blocker in a Single Scan: Phantom Studies
    Dong, Xue
    Petrongolo, Michael
    Niu, Tianye
    Zhu, Lei
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
  • [5] Single Scan Scatter Correction in Cone Beam CT Using a Stationary Boundary Blocker and Compressed Sensing-based Scatter Estimation
    Meng, B.
    Lee, H.
    Xing, L.
    Fahimian, B. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S82 - S83
  • [6] Single-Scan Scatter Correction for Volumetric CT Using a Stationary Beam Blocker: Phantom Studies
    Niu, T.
    Zhu, L.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [7] Scatter measurement and correction method for cone-beam CT based on single grating scan
    Huang, Kuidong
    Shi, Wenlong
    Wang, Xinyu
    Dong, Yin
    Chang, Taoqi
    Zhang, Hua
    Zhang, Dinghua
    OPTICAL ENGINEERING, 2017, 56 (06)
  • [8] Development of a beam stop array system with dual scan mode for scatter correction of cone-beam CT
    So Hyun Ahn
    Jinho Choi
    Kyu Chan Lee
    Siyong Kim
    Rena Lee
    Journal of the Korean Physical Society, 2014, 64 : 1220 - 1229
  • [9] Development of a Beam Stop Array System with Dual Scan Mode for Scatter Correction of Cone-beam CT
    Ahn, So Hyun
    Choi, Jinho
    Lee, Kyu Chan
    Kim, Siyong
    Lee, Rena
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (08) : 1220 - 1229
  • [10] A Moving Blocker System for Cone-Beam Computed Tomography Scatter Correction
    Ouyang, L.
    Song, K.
    Solberg, T.
    Wang, J.
    MEDICAL PHYSICS, 2013, 40 (06)