Comparison of cuffed and uncuffed preformed oral pediatric tracheal tubes

被引:21
|
作者
Weiss, Markus
Bernet, Vera
Stutz, Katharina
Dullenkopf, Alexander
Maino, Paolo
机构
[1] Univ Zurich, Childrens Hosp, Dept Anaesthesia, CH-8032 Zurich, Switzerland
[2] Univ Zurich, Childrens Hosp, Dept Neonatol & Intens Care Med, CH-8032 Zurich, Switzerland
关键词
pediatric tracheal tubes : preformed; RAE : cuff; airway; morbidity : complications;
D O I
10.1111/j.1460-9592.2006.01844.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: In preformed cuffed tracheal tubes the position of the cuff within the airway is given by its distance to the tube bend placed at the lower teeth. The aim of this study was to compare the design of cuffed and uncuffed preformed pediatric oral tracheal tubes with regard to anatomical landmarks. Methods: Complete series of cuffed and uncuffed preformed oral pediatric tracheal tubes sized from internal diameter 3.0-7.0 mm if available were ordered from five different manufacturers. The distance from the bend to the distal tube tip and to the upper border of the cuff were measured and compared with anatomical airway landmarks in the developing child. Results: Between cuffed and uncuffed tracheal preformed tubes up to 37 mm differences in the bend-to-tracheal tube tip distances were found for given age groups. Thus uncuffed preformed tracheal tubes were more at risk for inadvertent endobronchial intubation than cuffed preformed tracheal tubes. Comparison of bend-to-upper border of the cuff distances with teeth-to-vocal cord distances calculated from anatomical data revealed that several of the tracheal tube cuffs become positioned within the subglottic larynx or even within the vocal cords when inserted according to the bend. Conclusions: There is a need for improvement in cuffed preformed pediatric tracheal tubes, namely a standard bend-to-tracheal tube tip distance to allow a safe insertion depth, a short cuff placed on the tube shaft as distally as possible and an intubation depth mark to verify a proper position of the cuff in the trachea.
引用
收藏
页码:734 / 742
页数:9
相关论文
共 50 条
  • [41] Cuffed versus uncuffed endotracheal tubes in children: a meta-analysis
    Shi, Fenmei
    Xiao, Ying
    Xiong, Wei
    Zhou, Qin
    Huang, Xiongqing
    JOURNAL OF ANESTHESIA, 2016, 30 (01) : 3 - 11
  • [42] Cuffed versus uncuffed endotracheal tubes in pediatrics: a meta-analysis
    Chen, Liang
    Zhang, Jun
    Pan, Guoshi
    Li, Xia
    Shi, Tianwu
    He, Wensheng
    OPEN MEDICINE, 2018, 13 (01): : 366 - 373
  • [43] Time to stop using uncuffed tracheal tubes in children?
    Bailey, C. R.
    ANAESTHESIA, 2018, 73 (02) : 147 - 150
  • [44] DETERMINANTS OF TRACHEAL INJURY BY CUFFED TRACHEOSTOMY TUBES
    DUNN, CR
    DUNN, DL
    MOSER, KM
    CHEST, 1974, 65 (02) : 128 - 135
  • [45] TRACHEAL STRICTURE SECONDARY TO CUFFED TRACHEOSTOMY TUBES
    RAINER, WG
    SANCHEZ, M
    CHEST, 1971, 59 (01) : 115 - &
  • [46] PRESSURE ON THE TRACHEAL MUCOSA FROM CUFFED TUBES
    LEIGH, JM
    MAYNARD, JP
    BRITISH MEDICAL JOURNAL, 1979, 1 (6172): : 1173 - 1174
  • [47] PRESSURE ON THE TRACHEAL MUCOSA FROM CUFFED TUBES
    NOTCUTT, WG
    BRITISH MEDICAL JOURNAL, 1979, 1 (6177): : 1566 - 1566
  • [48] PRESSURE ON THE TRACHEAL MUCOSA FROM CUFFED TUBES
    BARHAM, C
    STRUNIN, L
    HONEYBOURNE, D
    COSTELLO, J
    BRITISH MEDICAL JOURNAL, 1979, 1 (6180): : 1794 - 1794
  • [49] PRESSURE ON THE TRACHEAL MUCOSA FROM CUFFED TUBES
    ROUTH, G
    HANNING, CD
    LEDINGHAM, IMA
    BRITISH MEDICAL JOURNAL, 1979, 1 (6175): : 1425 - 1425
  • [50] PRESSURE ON THE TRACHEAL MUCOSA FROM CUFFED TUBES
    HOMI, J
    BRITISH MEDICAL JOURNAL, 1979, 1 (6174): : 1355 - 1355