Comparison of cuffed and uncuffed preformed oral pediatric tracheal tubes

被引:21
|
作者
Weiss, Markus
Bernet, Vera
Stutz, Katharina
Dullenkopf, Alexander
Maino, Paolo
机构
[1] Univ Zurich, Childrens Hosp, Dept Anaesthesia, CH-8032 Zurich, Switzerland
[2] Univ Zurich, Childrens Hosp, Dept Neonatol & Intens Care Med, CH-8032 Zurich, Switzerland
关键词
pediatric tracheal tubes : preformed; RAE : cuff; airway; morbidity : complications;
D O I
10.1111/j.1460-9592.2006.01844.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: In preformed cuffed tracheal tubes the position of the cuff within the airway is given by its distance to the tube bend placed at the lower teeth. The aim of this study was to compare the design of cuffed and uncuffed preformed pediatric oral tracheal tubes with regard to anatomical landmarks. Methods: Complete series of cuffed and uncuffed preformed oral pediatric tracheal tubes sized from internal diameter 3.0-7.0 mm if available were ordered from five different manufacturers. The distance from the bend to the distal tube tip and to the upper border of the cuff were measured and compared with anatomical airway landmarks in the developing child. Results: Between cuffed and uncuffed tracheal preformed tubes up to 37 mm differences in the bend-to-tracheal tube tip distances were found for given age groups. Thus uncuffed preformed tracheal tubes were more at risk for inadvertent endobronchial intubation than cuffed preformed tracheal tubes. Comparison of bend-to-upper border of the cuff distances with teeth-to-vocal cord distances calculated from anatomical data revealed that several of the tracheal tube cuffs become positioned within the subglottic larynx or even within the vocal cords when inserted according to the bend. Conclusions: There is a need for improvement in cuffed preformed pediatric tracheal tubes, namely a standard bend-to-tracheal tube tip distance to allow a safe insertion depth, a short cuff placed on the tube shaft as distally as possible and an intubation depth mark to verify a proper position of the cuff in the trachea.
引用
收藏
页码:734 / 742
页数:9
相关论文
共 50 条
  • [31] Cuffed or uncuffed tracheal tubes during anaesthesia in infants and small children: time to put the eternal discussion to rest?
    Lonnqvist, P. A.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (06) : 783 - 785
  • [32] CUFFED VS. UNCUFFED TRACHEAL TUBE USAGE IN A TERTIARY PICU
    Nishisaki, Akira
    Colborn, Shawn
    Ferry, Susan
    Watson, Christine
    Helfaer, Mark
    Brown, Calvin
    Berg, Robert
    Walls, Ron
    Nadkarni, Vinay
    CRITICAL CARE MEDICINE, 2009, 37 (12) : A458 - A458
  • [33] Length of preformed tracheal tubes
    Edsell, MEG
    McDonald, P
    ANAESTHESIA, 2005, 60 (09) : 940 - 941
  • [34] TRACHEAL STENOSIS SECONDARY TO CUFFED TUBES
    SOM, PM
    KHILNANI, MT
    KELLER, RJ
    SOM, ML
    MOUNT SINAI JOURNAL OF MEDICINE, 1973, 40 (05): : 652 - 665
  • [35] CUFFED TUBES AS A CAUSE OF TRACHEAL STENOSIS
    SHELLY, WM
    DAWSON, RB
    MAY, IA
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 57 (05): : 623 - &
  • [36] Shortcomings of cuffed paediatric tracheal tubes
    Weiss, M
    Dullenkopf, A
    Gysin, C
    Dillier, CM
    Gerber, AC
    BRITISH JOURNAL OF ANAESTHESIA, 2004, 92 (01) : 78 - 88
  • [37] Cuffed versus uncuffed endotracheal tubes in children: a meta-analysis
    Fenmei Shi
    Ying Xiao
    Wei Xiong
    Qin Zhou
    Xiongqing Huang
    Journal of Anesthesia, 2016, 30 : 3 - 11
  • [38] International survey on the use of cuffed vs uncuffed endotracheal tubes.
    Reyes, G
    Lorente, MJ
    Horowitz, IN
    Huseyni, TS
    Sulayman, R
    Jaimovich, DG
    PEDIATRICS, 1999, 104 (03) : 682 - 682
  • [39] COMPARISON OF PHYSICAL AND FLOW CHARACTERISTICS OF STREAMLINE AND NORMAL CUFFED TRACHEAL TUBES
    KALLA, GN
    VENKATARAMANA, J
    BRITISH JOURNAL OF ANAESTHESIA, 1987, 59 (12) : 1621 - 1628
  • [40] Cuffed vs. uncuffed tracheal tubes in children: a randomised controlled trial comparing leak, tidal volume and complications
    Chambers, N. A.
    Ramgolam, A.
    Sommerfield, D.
    Zhang, G.
    Ledowski, T.
    Thurm, M.
    Lethbridge, M.
    Hegarty, M.
    von Ungern-Sternberg, B. S.
    ANAESTHESIA, 2018, 73 (02) : 160 - 168