Comparison of cuffed and uncuffed preformed oral pediatric tracheal tubes

被引:21
|
作者
Weiss, Markus
Bernet, Vera
Stutz, Katharina
Dullenkopf, Alexander
Maino, Paolo
机构
[1] Univ Zurich, Childrens Hosp, Dept Anaesthesia, CH-8032 Zurich, Switzerland
[2] Univ Zurich, Childrens Hosp, Dept Neonatol & Intens Care Med, CH-8032 Zurich, Switzerland
关键词
pediatric tracheal tubes : preformed; RAE : cuff; airway; morbidity : complications;
D O I
10.1111/j.1460-9592.2006.01844.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: In preformed cuffed tracheal tubes the position of the cuff within the airway is given by its distance to the tube bend placed at the lower teeth. The aim of this study was to compare the design of cuffed and uncuffed preformed pediatric oral tracheal tubes with regard to anatomical landmarks. Methods: Complete series of cuffed and uncuffed preformed oral pediatric tracheal tubes sized from internal diameter 3.0-7.0 mm if available were ordered from five different manufacturers. The distance from the bend to the distal tube tip and to the upper border of the cuff were measured and compared with anatomical airway landmarks in the developing child. Results: Between cuffed and uncuffed tracheal preformed tubes up to 37 mm differences in the bend-to-tracheal tube tip distances were found for given age groups. Thus uncuffed preformed tracheal tubes were more at risk for inadvertent endobronchial intubation than cuffed preformed tracheal tubes. Comparison of bend-to-upper border of the cuff distances with teeth-to-vocal cord distances calculated from anatomical data revealed that several of the tracheal tube cuffs become positioned within the subglottic larynx or even within the vocal cords when inserted according to the bend. Conclusions: There is a need for improvement in cuffed preformed pediatric tracheal tubes, namely a standard bend-to-tracheal tube tip distance to allow a safe insertion depth, a short cuff placed on the tube shaft as distally as possible and an intubation depth mark to verify a proper position of the cuff in the trachea.
引用
收藏
页码:734 / 742
页数:9
相关论文
共 50 条
  • [1] Cost effectiveness of cuffed tracheal tubes versus uncuffed tracheal tubes in children
    Schmitz, A.
    Eschertzhuber, S.
    Salgo, B.
    Roth, W.
    Stutz, K.
    Gerber, A. C.
    Keller, Ch
    Weiss, M.
    SWISS MEDICAL WEEKLY, 2007, 137 : 16S - 16S
  • [2] Cuffed versus uncuffed pediatric endotracheal tubes
    Anthony M. -H. Ho
    Manoj K. Karmakar
    Canadian Journal of Anesthesia, 2006, 53 : 106 - 107
  • [3] Cuffed versus uncuffed pediatric endotracheal tubes
    Ho, AMH
    Karmakar, MK
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2006, 53 (01): : 106 - 107
  • [4] Postal survey of cuffed or uncuffed tracheal tubes used for paediatric tracheal inhibition
    Orliaguet, GA
    Renaud, E
    Lejay, M
    Meyer, PG
    Schmautz, E
    Telion, C
    Carli, PA
    PAEDIATRIC ANAESTHESIA, 2001, 11 (03): : 277 - 281
  • [5] Cuffed and Uncuffed Tubes and the Geometric Correlation with Pediatric Airway
    Galante, Dario
    Caruselli, Marco
    ANESTHESIOLOGY, 2013, 119 (04) : 988 - 989
  • [6] Cuffed and Uncuffed Tubes and the Geometric Correlation with Pediatric Airway Reply
    Litman, Ronald S.
    Maxwell, Lynne G.
    ANESTHESIOLOGY, 2013, 119 (04) : 989 - 990
  • [7] Cuffed and uncuffed tracheal tube in children
    Buoy, C. M.
    Suresh, S.
    BRITISH JOURNAL OF ANAESTHESIA, 2010, 104 (03) : 388 - 388
  • [8] Tracheal sealing characteristics of pediatric cuffed tracheal tubes
    Dullenkopf, A
    Schmitz, A
    Gerber, AC
    Weiss, M
    PEDIATRIC ANESTHESIA, 2004, 14 (10) : 825 - 830
  • [9] The use of cuffed versus uncuffed endotracheal tubes in pediatric intensive care
    Newth, CJL
    Rachman, B
    Patel, N
    Hammer, J
    JOURNAL OF PEDIATRICS, 2004, 144 (03): : 333 - 337
  • [10] Comparison of cuffed, uncuffed tracheal tubes and laryngeal mask airways in low flow pressure controlled ventilation in children
    Engelhardt, T
    Johnston, G
    Kumar, MM
    PEDIATRIC ANESTHESIA, 2006, 16 (02) : 140 - 143