An Operating Condition-Based Scheme to Alternate Between Control Strategies for Improved Steady-State and Transient Behavior

被引:9
|
作者
Maurelia, Eduardo [1 ]
Espinoza, Jose R. [1 ]
Silva, Cesar A. [2 ]
Rojas, Christian A. [2 ]
Melin, Pedro E. [3 ]
Espinosa, Eduardo E. [1 ]
机构
[1] Univ Concepcion, Dept Elect Engn, 160-C, Concepcion, Chile
[2] Univ Tecn Federico Santa Maria, Dept Elect Engn, Valparaiso 2390123, Chile
[3] Univ Bio Bio, Dept Elect & Elect Engn, Concepcion 4051381, Chile
关键词
Alternating mode control; current control; finite set model predictive control (FS-MPC); proportional integral-with sinusoidal pulse width modulation (PI-SPWM); predictive control; pulse-width modulation; MODEL-PREDICTIVE CONTROL; MEDIUM-VOLTAGE DRIVES; OPTIMAL PULSEWIDTH MODULATION; SWITCHING FREQUENCY; POWER CONVERTERS; IMPLEMENTATION; PWM; INVERTERS; DESIGN; SVPWM;
D O I
10.1109/TII.2015.2481791
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The control strategies that use modulation techniques have great acceptance in the current control of static power converters. Indeed, they offer a wide variety of alternatives to address the steady-state characteristics required by the system. Nevertheless, its computation and modulation delay negatively affects its dynamic performance. In order to improve the time response of the system, the modulator is avoided and the strategies of direct choice of the switching state have been presented. They can provide a very fast dynamic response; however, the absence of switching state sequences makes more complex the task of establishing specific switching features for improved steady-state performance. In this work, a control scheme that selects a specific control strategy according to the operating condition of the system is proposed. This allows using modulators to satisfy the switching characteristics required in steady-state and avoids its use when a rapid dynamic response is required. In addition, a soft transition method between the control strategies is presented to prevent unwanted behaviors when these are alternated. The proposed control scheme allows simplifying the design and keeps the main advantages of each selected strategy. To validate the scheme, experimental results are obtained for a control structure that alternates between a finite set model predictive control (direct type for rapid dynamic response) and a proportional integral (PI) control with sinusoidal pulse width modulation (SPWM) (modulated type for high steady-state performance).
引用
收藏
页码:1246 / 1254
页数:9
相关论文
共 42 条
  • [1] Comparison of alternate LSPMSM Topologies considering both Transient and Steady-State operating characteristics
    Pechlivanidou, Maria S. C.
    Kladas, Antonios G.
    2019 IEEE WORKSHOP ON ELECTRICAL MACHINES DESIGN, CONTROL AND DAGNOSIS (WEMDCD), VOL 1, 2019, : 40 - 45
  • [2] Switched Model Predictive Control for Improved Transient and Steady-State Performance
    Aguilera, Ricardo P.
    Lezana, Pablo
    Quevedo, Daniel E.
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2015, 11 (04) : 968 - 977
  • [3] New Repetitive Control With Improved Steady-State Performance and Accelerated Transient
    Chen, Xu
    Tomizuka, Masayoshi
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2014, 22 (02) : 664 - 675
  • [4] REDUCED-ORDER MODELS FOR DYNAMIC CONTROL OF A POWER-PLANT WITH AN IMPROVED TRANSIENT AND STEADY-STATE BEHAVIOR
    ALSAGGAF, UM
    ELECTRIC POWER SYSTEMS RESEARCH, 1993, 26 (01) : 79 - 85
  • [5] The bacterial chemotactic response reflects a compromise between transient and steady-state behavior
    Clark, DA
    Grant, LC
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (26) : 9150 - 9155
  • [6] Steady-state and transient control strategies for a two-stage turbocharged diesel engine
    Hu, Zhilong
    Deng, Kangyao
    Cui, Yi
    Yang, Xinxin
    Zhang, Baochuan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2018, 232 (09) : 1167 - 1179
  • [7] RELATIONSHIP BETWEEN TRANSIENT AND STEADY-STATE PERFORMANCE CRITERIA FOR CONTROL-SYSTEMS
    ELIAS, NR
    LAMBERT, TH
    MEASUREMENT AND CONTROL, 1977, 10 (06): : 223 - 228
  • [8] Application of a Control Scheme Based on Predictive and Linear Strategy for Improved Transient State and Steady-State Performance in a Single-Phase Quasi-Z-Source Inverter
    Diaz-Bustos, Manuel
    Baier, Carlos R.
    Torres, Miguel A.
    Melin, Pedro E.
    Acuna, Pablo
    SENSORS, 2022, 22 (07)
  • [9] MPC-based Steady-state Drift Control under Extreme Condition
    Guo, Hongyan
    Tang, Zhongqiu
    Liu, Jun
    Chen, Hong
    PROCEEDINGS OF THE 33RD CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2021), 2021, : 4708 - 4712
  • [10] Improved Steady State and Transient Behavior of Static Power Converters by Means of an Operating Mode Identifier Algorithm
    Maurelia, E.
    Espinoza, J.
    Ramirez, R.
    Reyes, M.
    Melin, P.
    Silva, Cesar A.
    Munoz, Javier
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 870 - 875