An Operating Condition-Based Scheme to Alternate Between Control Strategies for Improved Steady-State and Transient Behavior

被引:9
|
作者
Maurelia, Eduardo [1 ]
Espinoza, Jose R. [1 ]
Silva, Cesar A. [2 ]
Rojas, Christian A. [2 ]
Melin, Pedro E. [3 ]
Espinosa, Eduardo E. [1 ]
机构
[1] Univ Concepcion, Dept Elect Engn, 160-C, Concepcion, Chile
[2] Univ Tecn Federico Santa Maria, Dept Elect Engn, Valparaiso 2390123, Chile
[3] Univ Bio Bio, Dept Elect & Elect Engn, Concepcion 4051381, Chile
关键词
Alternating mode control; current control; finite set model predictive control (FS-MPC); proportional integral-with sinusoidal pulse width modulation (PI-SPWM); predictive control; pulse-width modulation; MODEL-PREDICTIVE CONTROL; MEDIUM-VOLTAGE DRIVES; OPTIMAL PULSEWIDTH MODULATION; SWITCHING FREQUENCY; POWER CONVERTERS; IMPLEMENTATION; PWM; INVERTERS; DESIGN; SVPWM;
D O I
10.1109/TII.2015.2481791
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The control strategies that use modulation techniques have great acceptance in the current control of static power converters. Indeed, they offer a wide variety of alternatives to address the steady-state characteristics required by the system. Nevertheless, its computation and modulation delay negatively affects its dynamic performance. In order to improve the time response of the system, the modulator is avoided and the strategies of direct choice of the switching state have been presented. They can provide a very fast dynamic response; however, the absence of switching state sequences makes more complex the task of establishing specific switching features for improved steady-state performance. In this work, a control scheme that selects a specific control strategy according to the operating condition of the system is proposed. This allows using modulators to satisfy the switching characteristics required in steady-state and avoids its use when a rapid dynamic response is required. In addition, a soft transition method between the control strategies is presented to prevent unwanted behaviors when these are alternated. The proposed control scheme allows simplifying the design and keeps the main advantages of each selected strategy. To validate the scheme, experimental results are obtained for a control structure that alternates between a finite set model predictive control (direct type for rapid dynamic response) and a proportional integral (PI) control with sinusoidal pulse width modulation (SPWM) (modulated type for high steady-state performance).
引用
收藏
页码:1246 / 1254
页数:9
相关论文
共 42 条
  • [21] On the Use of Steady-State Optimal Initial Operating Conditions for Control Scheme Implementation of a Fixed-Bed Fischer–Tropsch Reactor
    César I. Méndez
    Fernando Trejo
    Jorge Ancheyta
    Arabian Journal for Science and Engineering, 2022, 47 : 6099 - 6113
  • [22] Space-Vector-Equalized Predictive Current Control Scheme for the Modular Multilevel Converter With Improved Steady-State Performance
    Xiao, Qian
    Jin, Yu
    Pou, Josep
    Jia, Hongjie
    Mu, Yunfei
    Teodorescu, Remus
    Blaabjerg, Frede
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (07) : 6470 - 6481
  • [23] An Improved Current Control Strategy Based on Particle Swarm Optimization and Steady-State Error Correction for SAPF
    Cao, Wu
    Liu, Kangli
    Wu, Mumu
    Xu, Sheng
    Zhao, Jianfeng
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (04) : 4268 - 4274
  • [24] Double Vector Based Model Predictive Torque Control for SPMSM Drives with Improved Steady-State Performance
    Zhang, Xiaoguang
    He, Yikang
    Hou, Benshuai
    JOURNAL OF POWER ELECTRONICS, 2018, 18 (05) : 1398 - 1408
  • [25] On the Use of Steady-State Optimal Initial Operating Conditions for Control Scheme Implementation of a Fixed-Bed Fischer-Tropsch Reactor
    Mendez, Cesar I.
    Trejo, Fernando
    Ancheyta, Jorge
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2022, 47 (05) : 6099 - 6113
  • [26] Resistive wall mode feedback control in EXTRAP T2R with improved steady-state error and transient response
    Brunsell, P. R.
    Olofsson, K. E. J.
    Frassinetti, L.
    Drake, J. R.
    PHYSICS OF PLASMAS, 2007, 14 (10)
  • [27] Improved transient and steady-state performance of series resonant ZCS high-frequency inverter-coupled voltage multiplier converter with dual mode PFM control scheme
    Chu, EH
    Gamage, L
    Ishitobi, M
    Hiraki, E
    Nakaoka, M
    ELECTRICAL ENGINEERING IN JAPAN, 2004, 149 (04) : 60 - 72
  • [28] An instantaneous power theory based control scheme for unified power flow controller in transient and steady state conditions
    Haghighat, H
    Scifi, H
    Yazdian, A
    ELECTRIC POWER SYSTEMS RESEARCH, 2003, 64 (03) : 175 - 180
  • [29] Implementation of a novel control-protective scheme on laboratorial HVDC system to distinguish between transient and steady state faults
    Habibinia, D.
    Shoulaie, A.
    Ghandehari, R.
    2007 42ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2007, : 470 - 474
  • [30] A Novel Attracting-Law based Digital Control Strategy with Improved Convergence Rate and Steady-State Error
    Wu, Lingwei
    Sun, Mingxuan
    PROCEEDINGS OF 2020 IEEE 9TH DATA DRIVEN CONTROL AND LEARNING SYSTEMS CONFERENCE (DDCLS'20), 2020, : 1198 - 1202