Titanium Niobium Nitride Mobile-Bearing Unicompartmental Knee Arthroplasty Results in Good to Excellent Clinical and Radiographic Outcomes in Metal Allergy Patients With Medial Knee Osteoarthritis

被引:11
|
作者
D'Ambrosi, Riccardo [1 ]
Nuara, Alessandro [1 ,2 ]
Mariani, Ilaria [3 ]
Di Feo, Fabrizio [1 ]
Ursino, Nicola [1 ]
Hirschmann, Michael [4 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, Via Galeazzi 4, I-20161 Milan, Italy
[2] Univ Milan, Milan, Italy
[3] Univ Milano Bicocca, Milan, Italy
[4] Kantonsspital Baselland, Dept Orthopaed Surg & Traumatol, Baselland, Switzerland
来源
JOURNAL OF ARTHROPLASTY | 2021年 / 36卷 / 01期
关键词
unicompartmental knee arthroplasty; unicondylar; hypoallergenic; metal hypersensitivity; mobile bearing; TiNbN; SURGICAL INSTRUMENTATION; OXIDIZED ZIRCONIUM; FEMORAL COMPONENTS; HYPERSENSITIVITY; POLYETHYLENE; IMPLANTS; REVISION; RISK; WEAR; HIP;
D O I
10.1016/j.arth.2020.07.028
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The main purpose of the present study was to analyze the clinical and radiological outcomes of patients with positive skin patch tests who underwent medial mobile-bearing titanium niobium nitride unicompartmental knee arthroplasty (UKA) during a mid-term follow-up. Methods: Thirty-seven patients with positive skin patch tests were included in this prospective study. The clinical evaluation consisted of Oxford Knee Score and Knee Society Score (KSS) reports. Each patient was clinically evaluated the day before surgery (T-0) as well as at T-1 (11.9 +/- 1.3 months) and during the final follow-up T-2 (67.2 +/- 19.1 months). The positioning of the UKA was evaluated during the final follow-up using standardized radiographs (T-2 : 67.2 +/- 19.1 months). Results: Oxford and KSS ranged from a respective mean preoperative value of 23.0 +/- 2.7 and 51.5 +/- 5.0 to 42.1 +/- 1.7 and 87.6 +/- 2.2, respectively, at T-1 (P < .001) and to the final values of 45.0 +/- 1.9 and 91.9 +/- 3.4, respectively, at T-2 (P < .001 both vs T-1 and T-2). At T-2, the mean femoral angle was 7.0 degrees +/- 4.5 degrees, mean tibial angle was 3.0 degrees +/- 2.1 degrees, and mean tibial slope was 5.1 degrees +/- 3.2 degrees. A significant difference was found between KSS and Oxford with ANOVA for repeated measures over time (P < .001). The Oxford and KSS scores showed significant improvements during each follow-up. No complications were found, and not a single patient required a revision surgery during the follow-up period. Conclusion: The hypoallergenic titanium niobium nitride mobile-bearing UKA showed comparable results to standard CoCr UKA regardless of the gender, age, BMI, and implant size of metal allergy patients with medial knee osteoarthritis. Careful patient selection processes and accurate medical histories played key roles in the choice of hypersensitivity-friendly implants. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:140 / +
页数:10
相关论文
共 50 条
  • [31] Early outcomes of twin-peg mobile-bearing unicompartmental knee arthroplasty compared with primary total knee arthroplasty
    Lum, Z. C.
    Lombardi, A. V.
    Hurst, J. M.
    Morris, M. J.
    Adams, J. B.
    Berend, K. R.
    BONE & JOINT JOURNAL, 2016, 98B : 28 - 33
  • [32] Outcomes of fixed versus mobile- bearing medial unicompartmental knee arthroplasty
    Fricka, K. B.
    Wilson, E. J.
    Strait, A., V
    Ho, H.
    Hopper Jr, R. H.
    Hamilton, W. G.
    Sershon, R. A.
    BONE & JOINT JOURNAL, 2024, 106B (09): : 916 - 923
  • [33] Impact of joint line orientation on clinical outcomes in bilateral Oxford mobile-bearing unicompartmental knee arthroplasty
    Nishida, Ryota
    Hiranaka, Takafumi
    Kamenaga, Tomoyuki
    Hida, Yuichi
    Fujishiro, Takaaki
    Okamoto, Koji
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    KNEE, 2021, 28 : 186 - 193
  • [34] Impact of Polyethylene Thickness on Clinical Outcomes and Survivorship in Medial Mobile-Bearing Unicondylar Knee Arthroplasty
    Crawford, David A.
    Lapsley, Lauren
    Hurst, Jason M.
    Morris, Michael J.
    Lombardi, Adolph V., Jr.
    Berend, Keith R.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (07): : 2440 - 2444
  • [35] Medial Mobile-Bearing Unicompartmental Knee Arthroplasty in Young Patients Aged Less Than or Equal to 50 Years
    Greco, Nicholas J.
    Lombardi, Adolph V., Jr.
    Price, Andrew J.
    Berend, Michael E.
    Berend, Keith R.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (08): : 2435 - 2439
  • [36] Medial fixed-bearing unicompartmental knee arthroplasty in patients with or without patellofemoral osteoarthritis: is there any difference in clinical outcomes?
    de Abreu-e-Silva, Guilherme Moreira
    Reis, Igor Guedes Nogueira
    Bueno, Elton
    Campos, Tulio Vinicius de Oliveira
    Gobbi, Riccardo
    Kruel, Andre
    de Andrade, Marco Antonio Percope
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2025, 35 (01):
  • [37] Reduced Bearing Excursion After Mobile-Bearing Unicompartmental Knee Arthroplasty is Associated With Poor Functional Outcomes
    Wahal, Naman
    Gaba, Sahil
    Malhotra, Rajesh
    Kumar, Vijay
    Pegg, Elise C.
    Pandit, Hemant
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02): : 366 - 371
  • [38] The effect of body mass index on the outcomes of cementless medial mobile-bearing unicompartmental knee replacements
    Mohammad, Hasan Raza
    Mellon, Stephen
    Judge, Andrew
    Dodd, Christopher
    Murray, David
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (02) : 608 - 618
  • [39] Mobile-bearing medial unicompartmental knee arthroplasty restores limb alignment comparable to that of the unaffected contralateral limb
    Mullaji, Arun B.
    Shah, Siddharth
    Shetty, Gautam M.
    ACTA ORTHOPAEDICA, 2017, 88 (01) : 70 - 74
  • [40] Valgus Stress Radiograph Can Predict Alignment Change of Medial Mobile-Bearing Unicompartmental Knee Arthroplasty
    Jiao, Xufeng
    Li, Zheng
    Du, Mincong
    An, Shuai
    Huang, Jiang
    Cao, Guanglei
    ORTHOPAEDIC SURGERY, 2023, 15 (07) : 1847 - 1853