Titanium Niobium Nitride Mobile-Bearing Unicompartmental Knee Arthroplasty Results in Good to Excellent Clinical and Radiographic Outcomes in Metal Allergy Patients With Medial Knee Osteoarthritis

被引:11
|
作者
D'Ambrosi, Riccardo [1 ]
Nuara, Alessandro [1 ,2 ]
Mariani, Ilaria [3 ]
Di Feo, Fabrizio [1 ]
Ursino, Nicola [1 ]
Hirschmann, Michael [4 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, Via Galeazzi 4, I-20161 Milan, Italy
[2] Univ Milan, Milan, Italy
[3] Univ Milano Bicocca, Milan, Italy
[4] Kantonsspital Baselland, Dept Orthopaed Surg & Traumatol, Baselland, Switzerland
来源
JOURNAL OF ARTHROPLASTY | 2021年 / 36卷 / 01期
关键词
unicompartmental knee arthroplasty; unicondylar; hypoallergenic; metal hypersensitivity; mobile bearing; TiNbN; SURGICAL INSTRUMENTATION; OXIDIZED ZIRCONIUM; FEMORAL COMPONENTS; HYPERSENSITIVITY; POLYETHYLENE; IMPLANTS; REVISION; RISK; WEAR; HIP;
D O I
10.1016/j.arth.2020.07.028
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The main purpose of the present study was to analyze the clinical and radiological outcomes of patients with positive skin patch tests who underwent medial mobile-bearing titanium niobium nitride unicompartmental knee arthroplasty (UKA) during a mid-term follow-up. Methods: Thirty-seven patients with positive skin patch tests were included in this prospective study. The clinical evaluation consisted of Oxford Knee Score and Knee Society Score (KSS) reports. Each patient was clinically evaluated the day before surgery (T-0) as well as at T-1 (11.9 +/- 1.3 months) and during the final follow-up T-2 (67.2 +/- 19.1 months). The positioning of the UKA was evaluated during the final follow-up using standardized radiographs (T-2 : 67.2 +/- 19.1 months). Results: Oxford and KSS ranged from a respective mean preoperative value of 23.0 +/- 2.7 and 51.5 +/- 5.0 to 42.1 +/- 1.7 and 87.6 +/- 2.2, respectively, at T-1 (P < .001) and to the final values of 45.0 +/- 1.9 and 91.9 +/- 3.4, respectively, at T-2 (P < .001 both vs T-1 and T-2). At T-2, the mean femoral angle was 7.0 degrees +/- 4.5 degrees, mean tibial angle was 3.0 degrees +/- 2.1 degrees, and mean tibial slope was 5.1 degrees +/- 3.2 degrees. A significant difference was found between KSS and Oxford with ANOVA for repeated measures over time (P < .001). The Oxford and KSS scores showed significant improvements during each follow-up. No complications were found, and not a single patient required a revision surgery during the follow-up period. Conclusion: The hypoallergenic titanium niobium nitride mobile-bearing UKA showed comparable results to standard CoCr UKA regardless of the gender, age, BMI, and implant size of metal allergy patients with medial knee osteoarthritis. Careful patient selection processes and accurate medical histories played key roles in the choice of hypersensitivity-friendly implants. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:140 / +
页数:10
相关论文
共 50 条
  • [21] Early Complications After Minimally Invasive Mobile-Bearing Medial Unicompartmental Knee Arthroplasty
    Song, Moo-Ho
    Kim, Bu-Hwan
    Ahn, Seong-Jun
    Yoo, Seong-Ho
    Lee, Min-Soo
    JOURNAL OF ARTHROPLASTY, 2009, 24 (08): : 1281 - 1284
  • [22] The Mediolateral Excursion of the Meniscal Bearing during Flexion and Extension of the Knee after Medial Mobile-Bearing Unicompartmental Knee Arthroplasty
    Lee, Seung-Yup
    Bae, Ji-Hoon
    Suh, Dong-Won
    Kim, Han-Ju
    Lim, Hong-Chul
    JOURNAL OF KNEE SURGERY, 2017, 30 (02) : 107 - 113
  • [23] The effect of tibial component rotational alignment on clinical outcomes of mobile-bearing unicompartmental knee arthroplasty
    Zhou, Xiaoqiang
    Sun, Chao
    Xu, Renjie
    Zhang, Xiangxin
    Yu, Xiao
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [24] The effect of tibial component rotational alignment on clinical outcomes of mobile-bearing unicompartmental knee arthroplasty
    Xiaoqiang Zhou
    Chao Sun
    Renjie Xu
    Xiangxin Zhang
    Xiao Yu
    Journal of Orthopaedic Surgery and Research, 18
  • [25] Mid-term outcomes of mobile-bearing lateral unicompartmental knee arthroplasty
    Fornell, S.
    Prada, E.
    Barrena, P.
    Garcia-Mendoza, A.
    Borrego, E.
    Domecq, G.
    KNEE, 2018, 25 (06): : 1206 - 1213
  • [26] The effect of BMI on the mid-term clinical outcomes of mobile-bearing unicompartmental knee arthroplasty
    Yikai Liu
    Huanshen Gao
    Tao Li
    Zian Zhang
    Haining Zhang
    BMC Musculoskeletal Disorders, 23
  • [27] The effect of BMI on the mid-term clinical outcomes of mobile-bearing unicompartmental knee arthroplasty
    Liu, Yikai
    Gao, Huanshen
    Li, Tao
    Zhang, Zian
    Zhang, Haining
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [28] Mid-term functional, clinical, and radiological outcomes with factors affecting revision of mobile-bearing medial unicompartmental knee arthroplasty
    Uzun, Erdal
    Misir, Abdulhamit
    Kizkapan, Turan Bilge
    Ozcamdalli, Mustafa
    Gunay, Ali Eray
    Husrevoglu, Kazim
    KNEE, 2020, 27 (02): : 527 - 534
  • [29] Similar clinical and radiographic outcomes after two different hypoallergenic medial unicompartmental knee in patients with metal allergy
    D'Ambrosi, Riccardo
    Ursino, Nicola
    Mariani, Ilaria
    Corona, Katia
    Anghilieri, Filippo Maria
    Franchi, Emanuele
    Monti, Lorenzo
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (04): : 1315 - 1328
  • [30] Similar clinical and radiographic outcomes after two different hypoallergenic medial unicompartmental knee in patients with metal allergy
    Riccardo D’Ambrosi
    Nicola Ursino
    Ilaria Mariani
    Katia Corona
    Filippo Maria Anghilieri
    Emanuele Franchi
    Lorenzo Monti
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 1315 - 1328