Imprinted Zeolite Modified Carbon Paste Electrode as A Selective Potentiometric Sensor for Blood Glucose

被引:2
|
作者
Khasanah, Miratul [1 ]
Widati, Alfa Akustia [1 ]
Handajani, Usreg Sri [1 ]
Shofiyyah, Masfah Raudlotus [1 ]
Rakhma, Sabrina Aulia [1 ]
Predianto, Herwin [1 ]
机构
[1] Airlangga Univ, Fac Sci & Technol, Chem Dept, Kampus C Unair, Surabaya 60115, Indonesia
来源
关键词
CONSTRUCTION;
D O I
10.1063/5.0005231
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Imprinted zeolite modified carbon paste electrode as a potentiometric sensor for glucose analysis in blood serum sample has been developed. In this study, the type of used zeolite was TS-1. Imprinted zeolite (IZ) was synthesized with mole ratio of glucose/Si of 0.0306. The modified electrode prepared by mixing activated carbon, imprinted zeolite, and paraffin granule with mass ratio 9:4:7 from the measurement in range of 10(-5) - 10(-2) M is with Nernst factor of 28.6 mV/decade, and the detection limit of 4.79 x 10(-5) M. The electrode was able to respond the glucose molecules in solution quickly (<30 s), stable for more than 9 weeks (130 times usage) and selective to glucose molecules. The urea, uric acid, and creatine with various concentrations did not interfere to glucose analysis by potentiometry using the electrode. Applying of the electrode for glucose analysis in spiked blood serum samples showed that it had recovery of 91.73 +/- 3.48% (n=5), while its accuracy against spectrophotometry method as commonly used method in medical field was 90.58 +/- 4.65% (n=5). Based on its performance, potentiometry using the imprinted zeolite modified carbon paste electrode is recommended as an alternative method for routine blood glucose analysis in the medical field.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Selective Identification for Glucose in the Presence of Fructose Using Imprinted Polyeugenol Modified Graphite Paste Electrode
    Djunaidi, Muhammad Cholid
    Gunawan, Gunawan
    Cahyaningrum, Lutfia
    Lusiana, Retno Ariadi
    Khasanah, Miratul
    [J]. INDONESIAN JOURNAL OF CHEMISTRY, 2022, 22 (04) : 913 - 921
  • [22] Nickel-Zeolite modified carbon paste electrode as electrochemical sensor for hydrogen peroxide
    Banafsheh Norouzi
    Ali Malekan
    Majid Moradian
    [J]. Russian Journal of Electrochemistry, 2016, 52 : 330 - 339
  • [23] Nickel-Zeolite modified carbon paste electrode as electrochemical sensor for hydrogen peroxide
    Norouzi, Banafsheh
    Malekan, Ali
    Moradian, Majid
    [J]. RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2016, 52 (04) : 330 - 339
  • [24] High-Selective Tramadol Sensor Based on Modified Molecularly Imprinted Polymer-Carbon Paste Electrode with Multiwalled Carbon Nanotubes
    Soleimani, Majid
    Afshar, Majid Ghahraman
    Shafaat, Atefeh
    Crespo, Gaston A.
    [J]. ELECTROANALYSIS, 2013, 25 (05) : 1159 - 1168
  • [25] A new selective carbon paste electrode for potentiometric analysis of olanzapine
    Rouhani, Mina
    Soleymanpour, Ahmad
    [J]. MEASUREMENT, 2019, 140 : 472 - 478
  • [26] A New Potentiometric Sensor Based on Carbon Paste Electrode Modified with Methacrylic Acid Based-Ion Imprinted Polymer for Nickel Ion Determination
    Alizadeh, Taher
    Rashedi, Maryam
    Ghadiri, Amir Mohammad
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (10): : 860 - 873
  • [27] Development of piroxicam sensor based on molecular imprinted polymer-modified carbon paste electrode
    Gholivand, Mohammad Bagher
    Karimian, Nashmil
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (08): : 1844 - 1851
  • [28] Carbon Paste Electrode Modified Molecularly Imprinted Polymer as a Sensor for Creatinine Analysis by Stripping Voltammetry
    Khasanah, M.
    Darmokoesoemo, H.
    Rizki, D. A.
    [J]. 6TH INTERNATIONAL CONFERENCE AND WORKSHOPS ON BASIC AND APPLIES SCIENCES, 2017, 1888
  • [29] Application of surfactant modified zeolite carbon paste electrode (SMZ-CPE) towards potentiometric determination of sulfate
    Nezamzadeh-Ejhieh, Alireza
    Esmaeilian, Atena
    [J]. MICROPOROUS AND MESOPOROUS MATERIALS, 2012, 147 (01) : 302 - 309
  • [30] GLUCOSE SENSOR-BASED ON UBIQUINONE-MODIFIED CARBON-PASTE ELECTRODE
    KAWAKAMI, M
    URIUDA, N
    KOYA, H
    GONDO, S
    [J]. ANALYTICAL LETTERS, 1995, 28 (09) : 1555 - 1569