Calibration-free wavelength-modulation spectroscopy for measurements of gas temperature and concentration in harsh environments

被引:452
|
作者
Rieker, Gregory B. [1 ]
Jeffries, Jay B. [1 ]
Hanson, Ronald K. [1 ]
机构
[1] Stanford Univ, Dept Mech Engn, High Temp Gasdynam Lab, Stanford, CA 94305 USA
关键词
TUNABLE DIODE-LASER; WATER-VAPOR; HIGH-PRESSURE; ABSORPTION-SPECTROSCOPY; FREQUENCY-MODULATION; MU-M; SENSOR; SPECTROMETRY; COMBUSTION; FLOWS;
D O I
10.1364/AO.48.005546
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a practical implementation of calibration-free wavelength-modulation spectroscopy with second harmonic detection (WMS-2f) for measurements of gas temperature and concentration in harsh environments. The method is applicable to measurements using lasers with synchronous wavelength and intensity modulation (such as injection current-tuned diode lasers). The key factors that enable measurements without the on-site calibration normally associated with WMS are (1) normalization of the WMS-2f signal by the first harmonic (1f) signal to account for laser intensity, and (2) the inclusion of laser-specific tuning characteristics in the spectral-absorption model that is used to compare with measured 1f-normalized, WMS-2f signals to infer gas properties. The uncertainties associated with the calibration-free WMS method are discussed, with particular emphasis on the influence of pressure and optical depth on the WMS signals. Many of these uncertainties are also applicable to calibrated WMS measurements. An example experimental setup that combines six tunable diode laser sources between 1.3 and 2.0 mu m into one probe beam for measurements of temperature, H2O, and CO2 is shown. A hybrid combination of wavelength and frequency demultiplexing is used to distinguish among the laser signals, and the optimal set of laser-modulation waveforms is presented. The system is demonstrated in the harsh environment of a ground-test scramjet combustor. A comparison of direct absorption and 1f-normalized, WMS-2f shows a factor of 4 increase in signal-to-noise ratio with the WMS technique for measurements of CO2 in the supersonic flow. Multidimensional computational fluid-dynamics (CFD) calculations are compared with measurements of temperature and H2O using a simple method that accounts for the influence of line-of-sight (LOS) nonuniformity on the absorption measurements. The comparisons show the ability of the LOS calibration-free technique to gain useful information about multidimensional CFD models. (C) 2009 Optical Society of America
引用
收藏
页码:5546 / 5560
页数:15
相关论文
共 50 条
  • [31] Calibration-free scanned wavelength modulation spectroscopy-application to H2O and temperature sensing in flames
    Qu, Zhechao
    Ghorbani, Ramin
    Valiev, Damir
    Schmidt, Florian M.
    OPTICS EXPRESS, 2015, 23 (12): : 16492 - 16499
  • [32] Cascade integrator comb filter-aided calibration-free Wavelength Modulation Spectroscopy Tomography
    Xia, Jiangnan
    Enemali, Godwin
    Zhang, Rui
    Liu, Chang
    2022 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2022), 2022,
  • [33] Tunable diode-laser Spectroscopy with wavelength modulation: A calibration-free approach to the recovery of absolute gas absorption line shapes
    Duffin, Kevin
    McGettrick, Andrew James
    Johnstone, Walter
    Stewart, George
    Moodie, David G.
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2007, 25 (10) : 3114 - 3125
  • [34] Dependence of harmonic signals on sample-gas parameters in wavelength-modulation spectroscopy for precise absorption measurements
    K. Uehara
    Applied Physics B, 1998, 67 : 517 - 523
  • [35] Calibration-Free Wavelength Modulation Spectroscopy for Gas Properties Measuring Basedon 2nd and 4th Harmonics
    Wang Yi-hong
    Zhou Bin
    Zhao Rong
    Wang Bu-bin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43 (02) : 368 - 373
  • [36] Dependence of harmonic signals on sample-gas parameters in wavelength-modulation spectroscopy for precise absorption measurements
    Uehara, K
    APPLIED PHYSICS B-LASERS AND OPTICS, 1998, 67 (04): : 517 - 523
  • [37] Standoff sub-ppb level measurement of atmospheric ammonia with calibration-free wavelength modulation spectroscopy
    Wang, Ruifeng
    Peng, Jie
    Chen, Jiajin
    Ti, Chaopu
    Wang, Guishi
    Liu, Kun
    Gao, Xiaoming
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 286
  • [38] Calibration-Free Wavelength Modulation Spectroscopy Method Based on the Height-Width Characteristic of Second Harmonic
    Wang Yihong
    Bin, Zhou
    Rong, Zhao
    Wang Bubin
    ACTA OPTICA SINICA, 2022, 42 (20)
  • [39] Intensity Modulation-Normalized Calibration-Free 1f and 2f Wavelength Modulation Spectroscopy
    Roy, Anirban
    Chakraborty, Arup Lal
    IEEE SENSORS JOURNAL, 2020, 20 (21) : 12691 - 12701
  • [40] Gas temperature measurements using wavelength modulation spectroscopy at 1.39 μm
    Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
    不详
    Opt Appl, 2009, 1 (13-29):