Calibration-free wavelength-modulation spectroscopy for measurements of gas temperature and concentration in harsh environments

被引:452
|
作者
Rieker, Gregory B. [1 ]
Jeffries, Jay B. [1 ]
Hanson, Ronald K. [1 ]
机构
[1] Stanford Univ, Dept Mech Engn, High Temp Gasdynam Lab, Stanford, CA 94305 USA
关键词
TUNABLE DIODE-LASER; WATER-VAPOR; HIGH-PRESSURE; ABSORPTION-SPECTROSCOPY; FREQUENCY-MODULATION; MU-M; SENSOR; SPECTROMETRY; COMBUSTION; FLOWS;
D O I
10.1364/AO.48.005546
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a practical implementation of calibration-free wavelength-modulation spectroscopy with second harmonic detection (WMS-2f) for measurements of gas temperature and concentration in harsh environments. The method is applicable to measurements using lasers with synchronous wavelength and intensity modulation (such as injection current-tuned diode lasers). The key factors that enable measurements without the on-site calibration normally associated with WMS are (1) normalization of the WMS-2f signal by the first harmonic (1f) signal to account for laser intensity, and (2) the inclusion of laser-specific tuning characteristics in the spectral-absorption model that is used to compare with measured 1f-normalized, WMS-2f signals to infer gas properties. The uncertainties associated with the calibration-free WMS method are discussed, with particular emphasis on the influence of pressure and optical depth on the WMS signals. Many of these uncertainties are also applicable to calibrated WMS measurements. An example experimental setup that combines six tunable diode laser sources between 1.3 and 2.0 mu m into one probe beam for measurements of temperature, H2O, and CO2 is shown. A hybrid combination of wavelength and frequency demultiplexing is used to distinguish among the laser signals, and the optimal set of laser-modulation waveforms is presented. The system is demonstrated in the harsh environment of a ground-test scramjet combustor. A comparison of direct absorption and 1f-normalized, WMS-2f shows a factor of 4 increase in signal-to-noise ratio with the WMS technique for measurements of CO2 in the supersonic flow. Multidimensional computational fluid-dynamics (CFD) calculations are compared with measurements of temperature and H2O using a simple method that accounts for the influence of line-of-sight (LOS) nonuniformity on the absorption measurements. The comparisons show the ability of the LOS calibration-free technique to gain useful information about multidimensional CFD models. (C) 2009 Optical Society of America
引用
收藏
页码:5546 / 5560
页数:15
相关论文
共 50 条
  • [2] Calibration-free wavelength modulation spectroscopy for gas concentration measurements using a quantum cascade laser
    Min Wei
    RuiFeng Kan
    Bing Chen
    ZhenYu Xu
    ChenGuang Yang
    Xiang Chen
    HuiHui Xia
    Mai Hu
    Yabai He
    JianGuo Liu
    XueLi Fan
    Wei Wang
    Applied Physics B, 2017, 123
  • [3] Calibration-free wavelength modulation spectroscopy for gas concentration measurements using a quantum cascade laser
    Wei, Min
    Kan, RuiFeng
    Chen, Bing
    Xu, ZhenYu
    Yang, ChenGuang
    Chen, Xiang
    Xia, HuiHui
    Hu, Mai
    He, Yabai
    Liu, JianGuo
    Fan, Xueli
    Wang, Wei
    APPLIED PHYSICS B-LASERS AND OPTICS, 2017, 123 (05):
  • [4] Calibration-free wavelength-modulation spectroscopy based on a swiftly determined wavelength-modulation frequency response function of a DFB laser
    Zhao, Gang
    Tan, Wei
    Hou, Jiajia
    Qiu, Xiaodong
    Ma, Weiguang
    Li, Zhixin
    Dong, Lei
    Zhang, Lei
    Yin, Wangbao
    Xiao, Liantuan
    Axner, Ove
    Jia, Suotang
    OPTICS EXPRESS, 2016, 24 (02): : 1723 - 1733
  • [5] Calibration-free wavelength modulation spectroscopy for gas concentration measurements under low-absorbance conditions
    Che Lu
    Ding Yan-Jun
    Peng Zhi-Min
    Li Xiao-Hang
    CHINESE PHYSICS B, 2012, 21 (12)
  • [6] Calibration-free wavelength modulation spectroscopy for gas concentration measurements under low-absorbance conditions
    车璐
    丁艳军
    彭志敏
    李晓航
    Chinese Physics B, 2012, 21 (12) : 463 - 470
  • [7] Tunable diode laser spectroscopy with wavelength modulation: A phasor decomposition method for calibration-free measurements of gas concentration and pressure
    McGettrick, Andrew James
    Duffin, Kevin
    Johnstone, Walter
    Stewart, Georgge
    Moodie, David G.
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2008, 26 (1-4) : 432 - 440
  • [8] Linear calibration-free wavelength modulation spectroscopy
    Li, Renjie
    Li, Fei
    Lin, Xin
    Yu, Xilong
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2023, 65 (05) : 1024 - 1030
  • [9] Calibration-free wavelength modulation absorption spectrum of gas
    Li Ning
    Weng Chun-Sheng
    ACTA PHYSICA SINICA, 2011, 60 (07)
  • [10] Calibration-free wavelength modulation for gas sensing in tunable diode laser absorption spectroscopy
    Lan, L. J.
    Ding, Y. J.
    Peng, Z. M.
    Du, Y. J.
    Liu, Y. F.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 117 (04): : 1211 - 1219