Direct aperture optimization of breast IMRT and the dosimetric impact of respiration motion

被引:18
|
作者
Zhang, Guowei [1 ]
Jiang, Ziping [1 ]
Shepard, David [1 ]
Zhang, Bin [1 ]
Yu, Cedric [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 20期
关键词
D O I
10.1088/0031-9155/51/20/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have studied the application of direct aperture optimization (DAO) as an inverse planning tool for breast IMRT. Additionally, we have analysed the impact of respiratory motion on the quality of the delivered dose distribution. From this analysis, we have developed guidelines for balancing the desire for a high-quality optimized plan with the need to create a plan that will not degrade significantly in the presence of respiratory motion. For a DAO optimized breast IMRT plan, the tangential fields incorporate a flash field to cover the range of respiratory motion. The inverse planning algorithm then optimizes the shapes and weights of additional segments that are delivered in combination with the open fields. IMRT plans were generated using DAO with the relative weights of the open segments varied from 0% to 95%. To assess the impact of breathing motion, the dose distribution for the optimized IMRT plan was recalculated with the isocentre sampled from a predefined distribution in a Monte Carlo convolution/superposition dose engine with the breast simulated as a rigid object. The motion amplitudes applied in this study ranged from 0.5 to 2.0 cm. For a range of weighting levels assigned to the open field, comparisons were made between the static plans and the plans recalculated with motion. For the static plans, we found that uniform dose distributions could be generated with relative weights for the open segments equal to and below 80% and unacceptable levels of underdosage were observed with the weights larger than 80%. When simulated breathing motion was incorporated into the dose calculation, we observed a loss in dose uniformity as the weight of the open field was decreased to below 65%. More quantitatively, for each 1% decrease in the weight, the per cent volume of the target covered by at least 95% of the prescribed dose decreased by approximately 0.10% and 0.16% for motion amplitudes equal to 1.5 cm and 2.0 cm, respectively. When taking into account the motion effects, the most uniform and conformal dose distributions were achieved when the open segment weights were in the range of 65-80%. Within this range, high-quality IMRT plans were produced for each case. The study demonstrates that DAO with tangential fields provides a robust and efficient technique for breast IMRT planning and delivery when the open segment weight is selected between 65% and 80%.
引用
收藏
页码:N357 / N369
页数:13
相关论文
共 50 条
  • [31] Direct aperture optimization based step-and-shoot IMRT with respiratory gating
    Ahunbay, E.
    Jursinic, P.
    Li, X. A.
    MEDICAL PHYSICS, 2006, 33 (06) : 2217 - 2217
  • [32] Clinical Evaluation of Direct Aperture Optimization in Head/Neck and Prostate IMRT Treatment
    Hosini, M.
    Galal, M.
    Emam, I.
    Kamal, G.
    Algohary, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 364 - 364
  • [33] The asymptotic limit of the number of field segments for IMRT using direct aperture optimization
    Jiang, Z
    Shepard, D
    Earl, M
    Naqvi, S
    Yu, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1715 - 1716
  • [34] Dosimetric impact of repeated DIBH in short-course breast IMRT and VMAT
    Penninkhof, Joan J.
    Zolnay, Andras G.
    Huijskens, Sophie C.
    van de Schoot, Agustinus J. A. J.
    Hoogeman, Mischa S.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4369 - S4371
  • [35] Dosimetric Evaluation of Aperture-Based and Beamlet-Based Optimization for Conventional IMRT/VMAT and SBRT
    Wu, D.
    Eldib, A.
    Jiang, Q.
    Chen, L.
    Ma, C.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [36] Dosimetric impact of respiratory movements for dynamic IMRT breast irradiation with a SIB technique
    Carrasco de Fez, P.
    Jornet, N.
    Latorre-Musoll, A.
    Eudaldo, T.
    Ruiz, A.
    Ribas, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S230 - S231
  • [37] Dosimetric effect of respiration-gated beam on IMRT delivery
    Duan, J
    Shen, S
    Fiveash, JB
    Brezovich, IA
    Popple, RA
    Pareek, PN
    MEDICAL PHYSICS, 2003, 30 (08) : 2241 - 2252
  • [38] Supraclavicular IMRT in breast cancer: A dosimetric study
    Gunn, G. B.
    Endres, E. J.
    Hatch, S. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S522 - S522
  • [39] Quantitative fluoroscopy of respiration-induced abdominal tumor motion and the impact of motion on IMRT dose distributions
    Gierga, D
    Chen, G
    Kung, J
    Betke, M
    Lombardi, J
    Willett, C
    MEDICAL PHYSICS, 2003, 30 (06) : 1340 - 1340
  • [40] RESPIRATORY ORGAN MOTION AND DOSIMETRIC IMPACT ON BREAST AND NODAL IRRADIATION
    Qi, X. Sharon
    White, Julia
    Rabinovitch, Rachel
    Merrell, Kenneth
    Sood, Amit
    Bauer, Anderson
    Wilson, J. Frank
    Miften, Moyed
    Li, X. Allen
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (02): : 609 - 617