Direct aperture optimization of breast IMRT and the dosimetric impact of respiration motion

被引:18
|
作者
Zhang, Guowei [1 ]
Jiang, Ziping [1 ]
Shepard, David [1 ]
Zhang, Bin [1 ]
Yu, Cedric [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 20期
关键词
D O I
10.1088/0031-9155/51/20/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have studied the application of direct aperture optimization (DAO) as an inverse planning tool for breast IMRT. Additionally, we have analysed the impact of respiratory motion on the quality of the delivered dose distribution. From this analysis, we have developed guidelines for balancing the desire for a high-quality optimized plan with the need to create a plan that will not degrade significantly in the presence of respiratory motion. For a DAO optimized breast IMRT plan, the tangential fields incorporate a flash field to cover the range of respiratory motion. The inverse planning algorithm then optimizes the shapes and weights of additional segments that are delivered in combination with the open fields. IMRT plans were generated using DAO with the relative weights of the open segments varied from 0% to 95%. To assess the impact of breathing motion, the dose distribution for the optimized IMRT plan was recalculated with the isocentre sampled from a predefined distribution in a Monte Carlo convolution/superposition dose engine with the breast simulated as a rigid object. The motion amplitudes applied in this study ranged from 0.5 to 2.0 cm. For a range of weighting levels assigned to the open field, comparisons were made between the static plans and the plans recalculated with motion. For the static plans, we found that uniform dose distributions could be generated with relative weights for the open segments equal to and below 80% and unacceptable levels of underdosage were observed with the weights larger than 80%. When simulated breathing motion was incorporated into the dose calculation, we observed a loss in dose uniformity as the weight of the open field was decreased to below 65%. More quantitatively, for each 1% decrease in the weight, the per cent volume of the target covered by at least 95% of the prescribed dose decreased by approximately 0.10% and 0.16% for motion amplitudes equal to 1.5 cm and 2.0 cm, respectively. When taking into account the motion effects, the most uniform and conformal dose distributions were achieved when the open segment weights were in the range of 65-80%. Within this range, high-quality IMRT plans were produced for each case. The study demonstrates that DAO with tangential fields provides a robust and efficient technique for breast IMRT planning and delivery when the open segment weight is selected between 65% and 80%.
引用
收藏
页码:N357 / N369
页数:13
相关论文
共 50 条
  • [21] Jaws-only IMRT using direct aperture optimization
    Earl, M. A.
    Afghan, M. K. N.
    Yu, C. X.
    Jiang, Z.
    Shepard, D. M.
    MEDICAL PHYSICS, 2007, 34 (01) : 307 - 314
  • [22] An exact approach to direct aperture optimization in IMRT treatment planning
    Men, Chunhua
    Romeijn, H. Edwin
    Taskin, Z. Caner
    Dempsey, James F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (24): : 7333 - 7352
  • [23] Direct aperture optimized IMRT vs. forward IMRT for whole breast irradiation
    Descovich, M.
    Bevan, A.
    Fowble, B. L.
    Schechter, N. R.
    Park, C.
    Xia, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S135 - S135
  • [24] Dosimetric Impact of Respiratory Motion in IMRT for breast cancer: 3D-Printed Dynamic Phantom Study
    Choi, Y. E.
    Sung, K.
    Dong, K. S.
    Kim, H. J.
    Lee, Y. K.
    Lim, Y.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S691 - S691
  • [25] A comparison between Direct Aperture Optimization and two commercial IMRT systems
    Earl, MA
    Naqvi, S
    Shepard, DM
    Yu, CX
    MEDICAL PHYSICS, 2003, 30 (06) : 1335 - 1335
  • [26] Direct aperture optimization: A turnkey solution for step-and-shoot IMRT
    Shepard, DM
    Earl, MA
    Li, XA
    Naqvi, S
    Yu, C
    MEDICAL PHYSICS, 2002, 29 (06) : 1007 - 1018
  • [27] Monte Carlo direct aperture optimization (MC-DAO) for IMRT
    Bergman, A. M.
    Bush, K.
    Milette, M.
    Popescu, I. A.
    Otto, K.
    Duzenli, C.
    MEDICAL PHYSICS, 2006, 33 (06) : 2198 - 2199
  • [28] Direct aperture optimization for IMRT using Monte Carlo generated beamlets
    Bergman, Alanah M.
    Bush, Karl
    Milette, Marie-Pierre
    Popescu, I. Antoniu
    Otto, Karl
    Duzenli, Cheryl
    MEDICAL PHYSICS, 2006, 33 (10) : 3666 - 3679
  • [29] Dynamic direct aperture optimization for 4D IMRT planning
    Armbruster, B
    Schreibmann, E
    Levy, D
    Xing, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S208 - S208
  • [30] The effects of respiration motion on dynamic IMRT
    Ramsey, C
    MEDICAL PHYSICS, 2002, 29 (06) : 1260 - 1261