Comparison of dual- and single-source dual-energy CT in head and neck imaging

被引:35
|
作者
May, Matthias Stefan [1 ]
Wiesmueller, Marco [1 ]
Heiss, Rafael [1 ]
Brand, Michael [1 ]
Bruegel, Joscha [1 ]
Uder, Michael [1 ]
Wuest, Wolfgang [1 ]
机构
[1] Univ Hosp Erlangen, Dept Radiol, Maximilianspl 3, D-91054 Erlangen, Germany
关键词
Diagnostic imaging; Head and neck neoplasms; Image enhancement; COMPUTED-TOMOGRAPHY; QUALITY;
D O I
10.1007/s00330-018-5762-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe aim of this study was to compare image quality of single-source dual-energy CT (SS-DECT) with third-generation dual-source dual-energy CT (DS-DECT) in head and neck cancer.Materials and methodsOne hundred two patients with histologically proven head and neck cancer were prospectively randomized to undergo radiation dose-matched SS-DECT (n=51, 120kV, split-filter technique, 384 ref. mAs) or DS-DECT (n=51, 80/Sn150kV, tube A 100/tube B 67 ref. mAs). Inline default images (DI) and virtual monoenergetic images (VMI) for two different low energies (40 and 60keV) were reconstructed. Objective image quality was evaluated as dose-normalized contrast to noise ratio (CNRD), and subjective image quality was rated on a 5-point Likert scale.ResultsIn both groups, highest CNRD values for vessel and tumor attenuation were obtained at 40keV. DS-DECT was significantly better than SS-DECT regarding vessel and tumor attenuation. Overall subjective image quality in the SS-DECT group was highest on the DI followed by 40keV and 60keV. In the DS-DECT group, subjective image quality was highest at 40keV followed by 60keV and the DI. Forty kiloelectron volts and 60keV were significantly better in the DS-DECT compared to the SS-DECT group (both p<0.01).ConclusionsIn split-filter SS-DECT as well as in DS-DECT, highest overall image quality in head and neck imaging can be obtained with a combination of DI and low keV reconstructions. DS-DECT is superior to split-filter SS-DECT in terms of subjective image quality and vessel and tumor attenuation.Key Points center dot Image quality was diagnostic with both dual-energy techniques; however, the dual-source technique delivered significantly better results.center dot Highest overall image quality in head and neck imaging can be obtained with a combination of default images and low keV reconstructions with both dual-energy techniques.center dot The results of this study may have relevance for the decision-making process regarding replacement of CT scanners and focused patient examination considering image quality and subsequent therapeutic decision-making.
引用
收藏
页码:4207 / 4214
页数:8
相关论文
共 50 条
  • [41] Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose
    Pinho, Daniella F.
    Kulkarni, Naveen M.
    Krishnaraj, Arun
    Kalva, Sanjeeva P.
    Sahani, Dushyant V.
    EUROPEAN RADIOLOGY, 2013, 23 (02) : 351 - 359
  • [42] Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose
    Daniella F. Pinho
    Naveen M. Kulkarni
    Arun Krishnaraj
    Sanjeeva P. Kalva
    Dushyant V. Sahani
    European Radiology, 2013, 23 : 351 - 359
  • [43] Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners
    Almeida, Isabel P.
    Schyns, Lotte E. J. R.
    Ollers, Michel C.
    van Elmpt, Wouter
    Parodi, Katia
    Landry, Guillaume
    Verhaegen, Frank
    MEDICAL PHYSICS, 2017, 44 (01) : 171 - 179
  • [44] Dual-energy CT and coronary imaging
    Kay, Fernando Uliana
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2020, 10 (04) : 1090 - 1107
  • [45] Imaging the Spine with Dual-Energy CT
    Murray N.
    Le M.
    Ebrahimzadeh O.
    Alharthy A.
    Mohammed M.F.
    Ouellette H.A.
    Khosa F.
    Current Radiology Reports, 5 (9)
  • [46] Dual-Energy CT in Oncologic Imaging
    Foti, Giovanni
    Ascenti, Giorgio
    Agostini, Andrea
    Longo, Chiara
    Lombardo, Fabio
    Inno, Alessandro
    Modena, Alessandra
    Gori, Stefania
    TOMOGRAPHY, 2024, 10 (03) : 299 - 319
  • [47] Dual-Energy Computed Tomography Angiography of the Head and Neck With Single-Source Computed Tomography: A New Technical (Split Filter) Approach for Bone Removal
    Kaemmerer, Nadine
    Brand, Michael
    Hammon, Matthias
    May, Matthias
    Wuest, Wolfgang
    Krauss, Bernhard
    Uder, Michael
    Lell, Michael M.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (10) : 618 - 623
  • [48] Improved imaging of colorectal liver metastases using single-source, fast kVp-switching, dual-energy CT: preliminary results
    Ratajczak, Przemyslaw
    Serafin, Zbigniew
    Slawinska, Agata
    Slupski, Maciej
    Leszczynski, Waldemar
    POLISH JOURNAL OF RADIOLOGY, 2018, 83 : E514 - E520
  • [49] Third generation dual-energy CT with 80/150 Sn kV for head and neck tumor imaging
    Suntharalingam, Saravanabavaan
    Stenzel, Elena
    Wetter, Axel
    Guberina, Nika
    Umutlu, Lale
    Schlosser, Thomas
    Nassenstein, Kai
    ACTA RADIOLOGICA, 2019, 60 (05) : 586 - 592
  • [50] Computed Tomography of the Head and Neck Region for Tumor Staging-Comparison of Dual-Source, Dual-Energy and Low-Kilovolt, Single-Energy Acquisitions
    May, Matthias Stefan
    Bruegel, Joscha
    Brand, Michael
    Wiesmueller, Marco
    Krauss, Bernhard
    Allmendinger, Thomas
    Uder, Michael
    Wuest, Wolfgang
    INVESTIGATIVE RADIOLOGY, 2017, 52 (09) : 522 - 528