Comparison of dual- and single-source dual-energy CT in head and neck imaging

被引:35
|
作者
May, Matthias Stefan [1 ]
Wiesmueller, Marco [1 ]
Heiss, Rafael [1 ]
Brand, Michael [1 ]
Bruegel, Joscha [1 ]
Uder, Michael [1 ]
Wuest, Wolfgang [1 ]
机构
[1] Univ Hosp Erlangen, Dept Radiol, Maximilianspl 3, D-91054 Erlangen, Germany
关键词
Diagnostic imaging; Head and neck neoplasms; Image enhancement; COMPUTED-TOMOGRAPHY; QUALITY;
D O I
10.1007/s00330-018-5762-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe aim of this study was to compare image quality of single-source dual-energy CT (SS-DECT) with third-generation dual-source dual-energy CT (DS-DECT) in head and neck cancer.Materials and methodsOne hundred two patients with histologically proven head and neck cancer were prospectively randomized to undergo radiation dose-matched SS-DECT (n=51, 120kV, split-filter technique, 384 ref. mAs) or DS-DECT (n=51, 80/Sn150kV, tube A 100/tube B 67 ref. mAs). Inline default images (DI) and virtual monoenergetic images (VMI) for two different low energies (40 and 60keV) were reconstructed. Objective image quality was evaluated as dose-normalized contrast to noise ratio (CNRD), and subjective image quality was rated on a 5-point Likert scale.ResultsIn both groups, highest CNRD values for vessel and tumor attenuation were obtained at 40keV. DS-DECT was significantly better than SS-DECT regarding vessel and tumor attenuation. Overall subjective image quality in the SS-DECT group was highest on the DI followed by 40keV and 60keV. In the DS-DECT group, subjective image quality was highest at 40keV followed by 60keV and the DI. Forty kiloelectron volts and 60keV were significantly better in the DS-DECT compared to the SS-DECT group (both p<0.01).ConclusionsIn split-filter SS-DECT as well as in DS-DECT, highest overall image quality in head and neck imaging can be obtained with a combination of DI and low keV reconstructions. DS-DECT is superior to split-filter SS-DECT in terms of subjective image quality and vessel and tumor attenuation.Key Points center dot Image quality was diagnostic with both dual-energy techniques; however, the dual-source technique delivered significantly better results.center dot Highest overall image quality in head and neck imaging can be obtained with a combination of default images and low keV reconstructions with both dual-energy techniques.center dot The results of this study may have relevance for the decision-making process regarding replacement of CT scanners and focused patient examination considering image quality and subsequent therapeutic decision-making.
引用
收藏
页码:4207 / 4214
页数:8
相关论文
共 50 条
  • [31] Accuracy of Dual-Energy Virtual Monochromatic CT Numbers: Comparison between the Single-Source Projection-Based and Dual-Source Image-Based Methods
    Ueguchi, Takashi
    Ogihara, Ryota
    Yamada, Sachiko
    ACADEMIC RADIOLOGY, 2018, 25 (12) : 1632 - 1639
  • [32] Dual-energy CT in the obese: a preliminary retrospective review to evaluate quality and feasibility of the single-source dual-detector implementation
    Atwi, Noah E.
    Smith, David L.
    Flores, Carson D.
    Dharaiya, Ekta
    Danrad, Raman
    Kambadakone, Avinash
    Toshav, Aran M.
    ABDOMINAL RADIOLOGY, 2019, 44 (02) : 783 - 789
  • [33] The value of single-source dual-energy CT imaging for discriminating microsatellite instability from microsatellite stability human colorectal cancer
    Jingjun Wu
    Yue Lv
    Nan Wang
    Ying Zhao
    Pengxin Zhang
    Yijun Liu
    Anliang Chen
    Jianying Li
    Xin Li
    Yan Guo
    Tingfan Wu
    Ailian Liu
    European Radiology, 2019, 29 : 3782 - 3790
  • [34] The value of single-source dual-energy CT imaging for discriminating microsatellite instability from microsatellite stability human colorectal cancer
    Wu, Jingjun
    Lv, Yue
    Wang, Nan
    Zhao, Ying
    Zhang, Pengxin
    Liu, Yijun
    Chen, Anliang
    Li, Jianying
    Li, Xin
    Guo, Yan
    Wu, Tingfan
    Liu, Ailian
    EUROPEAN RADIOLOGY, 2019, 29 (07) : 3782 - 3790
  • [35] The Value of Nonenhanced Single-Source Dual-Energy CT for Differentiating Metastases From Adenoma in Adrenal Glands
    Ju, Ye
    Liu, Ailian
    Dong, Yue
    Liu, Yijun
    Wang, Heqing
    Sun, Meiyu
    Pu, Renwang
    Chen, Anliang
    ACADEMIC RADIOLOGY, 2015, 22 (07) : 834 - 839
  • [36] Material differentiation in forensic radiology with single-source dual-energy computed tomography
    Thomas D. Ruder
    Yannick Thali
    Stephan A. Bolliger
    Sandra Somaini-Mathier
    Michael J. Thali
    Gary M. Hatch
    Sebastian T. Schindera
    Forensic Science, Medicine, and Pathology, 2013, 9 : 163 - 169
  • [37] Pancreatic dual-source dual-energy CT: Is it time to discard unenhanced imaging?
    Mileto, Achille
    Mazziotti, Silvio
    Gaeta, Michele
    Bottari, Antonio
    Zimbaro, Fabrizio
    Giardina, Claudio
    Ascenti, Giorgio
    CLINICAL RADIOLOGY, 2012, 67 (04) : 334 - 339
  • [38] Quantitative imaging of chemical composition using dual-energy, dual-source CT
    Liu, Xin
    Primak, Andrew N.
    Yu, Lifeng
    McCollough, Cynthia H.
    Morin, Richard L.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [39] Optimal window settings in single-source dual-energy computed tomography of the abdomen
    Noda, Yoshifumi
    Goshima, Satoshi
    Kozaka, Kazuto
    Yoneda, Norihide
    Mizuno, Nozomi
    Kato, Akiko
    Fujimoto, Keita
    Tsuji, Yusuke
    Miyoshi, Toshiharu
    Kawada, Hiroshi
    Kawai, Nobuyuki
    Tanahashi, Yukichi
    Matsuo, Masayuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 109 : 204 - 209
  • [40] Material differentiation in forensic radiology with single-source dual-energy computed tomography
    Ruder, Thomas D.
    Thali, Yannick
    Bolliger, Stephan A.
    Somaini-Mathier, Sandra
    Thali, Michael J.
    Hatch, Gary M.
    Schindera, Sebastian T.
    FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2013, 9 (02) : 163 - 169