Comparison of dual- and single-source dual-energy CT in head and neck imaging

被引:35
|
作者
May, Matthias Stefan [1 ]
Wiesmueller, Marco [1 ]
Heiss, Rafael [1 ]
Brand, Michael [1 ]
Bruegel, Joscha [1 ]
Uder, Michael [1 ]
Wuest, Wolfgang [1 ]
机构
[1] Univ Hosp Erlangen, Dept Radiol, Maximilianspl 3, D-91054 Erlangen, Germany
关键词
Diagnostic imaging; Head and neck neoplasms; Image enhancement; COMPUTED-TOMOGRAPHY; QUALITY;
D O I
10.1007/s00330-018-5762-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe aim of this study was to compare image quality of single-source dual-energy CT (SS-DECT) with third-generation dual-source dual-energy CT (DS-DECT) in head and neck cancer.Materials and methodsOne hundred two patients with histologically proven head and neck cancer were prospectively randomized to undergo radiation dose-matched SS-DECT (n=51, 120kV, split-filter technique, 384 ref. mAs) or DS-DECT (n=51, 80/Sn150kV, tube A 100/tube B 67 ref. mAs). Inline default images (DI) and virtual monoenergetic images (VMI) for two different low energies (40 and 60keV) were reconstructed. Objective image quality was evaluated as dose-normalized contrast to noise ratio (CNRD), and subjective image quality was rated on a 5-point Likert scale.ResultsIn both groups, highest CNRD values for vessel and tumor attenuation were obtained at 40keV. DS-DECT was significantly better than SS-DECT regarding vessel and tumor attenuation. Overall subjective image quality in the SS-DECT group was highest on the DI followed by 40keV and 60keV. In the DS-DECT group, subjective image quality was highest at 40keV followed by 60keV and the DI. Forty kiloelectron volts and 60keV were significantly better in the DS-DECT compared to the SS-DECT group (both p<0.01).ConclusionsIn split-filter SS-DECT as well as in DS-DECT, highest overall image quality in head and neck imaging can be obtained with a combination of DI and low keV reconstructions. DS-DECT is superior to split-filter SS-DECT in terms of subjective image quality and vessel and tumor attenuation.Key Points center dot Image quality was diagnostic with both dual-energy techniques; however, the dual-source technique delivered significantly better results.center dot Highest overall image quality in head and neck imaging can be obtained with a combination of default images and low keV reconstructions with both dual-energy techniques.center dot The results of this study may have relevance for the decision-making process regarding replacement of CT scanners and focused patient examination considering image quality and subsequent therapeutic decision-making.
引用
收藏
页码:4207 / 4214
页数:8
相关论文
共 50 条
  • [1] Comparison of dual- and single-source dual-energy CT in head and neck imaging
    Matthias Stefan May
    Marco Wiesmueller
    Rafael Heiss
    Michael Brand
    Joscha Bruegel
    Michael Uder
    Wolfgang Wuest
    European Radiology, 2019, 29 : 4207 - 4214
  • [2] Comparison of Dual- and Single-Source Dual-Energy CT for Diagnosis of Acute Pulmonary Artery Embolism
    Petritsch, Bernhard
    Pannenbecker, Pauline
    Weng, Andreas Max
    Veldhoen, Simon
    Grunz, Jan-Peter
    Bley, Thorsten Alexander
    Kosmala, Aleksander
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (04): : 427 - 436
  • [3] Dual-Energy CT in Head and Neck Imaging
    Roele E.D.
    Timmer V.C.M.L.
    Vaassen L.A.A.
    van Kroonenburgh A.M.J.L.
    Postma A.A.
    Current Radiology Reports, 5 (5)
  • [4] Dual-Energy CT Applications in Head and Neck Imaging
    Vogl, Thomas J.
    Schulz, Boris
    Bauer, Ralf W.
    Stoever, Timo
    Sader, Robert
    Tawfik, Ahmed M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S34 - S39
  • [5] Clinical applications of dual-energy CT in head and neck imaging
    Ginat, Daniel Thomas
    Mayich, Michael
    Daftari-Besheli, Laleh
    Gupta, Rajiv
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (03) : 547 - 553
  • [6] Clinical applications of dual-energy CT in head and neck imaging
    Daniel Thomas Ginat
    Michael Mayich
    Laleh Daftari-Besheli
    Rajiv Gupta
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 547 - 553
  • [7] Advanced dual-energy CT for head and neck cancer imaging
    Forghani, Reza
    EXPERT REVIEW OF ANTICANCER THERAPY, 2015, 15 (12) : 1489 - 1501
  • [8] Low-dose dual-energy CT for stone characterization: a systematic comparison of two generations of split-filter single-source and dual-source dual-energy CT
    Nakhostin, Dominik
    Sartoretti, Thomas
    Eberhard, Matthias
    Krauss, Bernhard
    Mueller, Daniel
    Alkadhi, Hatem
    Euler, Andre
    ABDOMINAL RADIOLOGY, 2021, 46 (05) : 2079 - 2089
  • [9] Clinical Implementation of Single-Source, Dual-Energy CT Simulation in Radiotherapy
    Smith, A.
    Hyun, M.
    Zheng, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E148 - E148
  • [10] Low-dose dual-energy CT for stone characterization: a systematic comparison of two generations of split-filter single-source and dual-source dual-energy CT
    Dominik Nakhostin
    Thomas Sartoretti
    Matthias Eberhard
    Bernhard Krauss
    Daniel Müller
    Hatem Alkadhi
    André Euler
    Abdominal Radiology, 2021, 46 : 2079 - 2089