A new implant with solid core and porous surface: The biocompatability with bone

被引:13
|
作者
Yang, Xu [1 ]
Wang, Dihua [2 ]
Liang, Youde [1 ]
Yin, Huayi [2 ]
Zhang, Shuang [1 ]
Jiang, Tao [1 ]
Wang, Yining [1 ]
Zhou, Yi [1 ]
机构
[1] Wuhan Univ, Sch & Hosp Stomatol, Key Lab Oral Biomed Engn, Minist Educ, Wuhan 430079, Peoples R China
[2] Wuhan Univ, Sch Resource & Environm Sci, Dept Environm Engn, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
Farthing-Fray-Chen (FFC); cambridge process; porous titanium; osteointegration; TOTAL HIP-ARTHROPLASTY; OSTEOBLAST-LIKE CELLS; GENE-EXPRESSION; TITANIUM IMPLANTS; IN-VITRO; INTEGRATION; OSSEOINTEGRATION; INGROWTH; TOPOGRAPHY; REDUCTION;
D O I
10.1002/jbm.a.34906
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This research investigated osteogenic potencies of Farthing-Fray-Chen Titanium (FFcTi) implant with transitional porous-solid structure. The material characteristics, biomechanical property, osteogenic performances were assessed. FFcTi showed similar roughness as sand-blasted and acid etched titanium (SA), but was more hydrophilic than SA and machined commercial pure titanium (MA). Young's modulus of FFcTi implant in compressive tests was 15.8 +/- 6.3 GPa, which was close to bone. In vitro observations manifested excellent spreading abilities of MC3T3-E1 cell on FFcTi and SA. Adhesion rates of MC3T3-E1 cells at 4 h gradually decreased on MA, SA, and FFcTi surfaces (MA>SA, p<0.01; SA>FFcTi, p<0.05), while cell proliferation ability on FFcTi was weaker than MA during 1-6 days (p<0.01) and similar to MA and SA in day 11. ALP activity of cells on FFcTi at 14 day was higher than MA and lower than SA (p<0.01). In a bone defect model of rabbits, BIC and bone volum ratio within 50 m were significantly higher for FFcTi than MA (BIC, p<0.01; BT0.05, p<0.05) while bone volume ratio within 100 and 500 m were of no differences. Micro CT analysis also showed similar results to the histomorphometric data. Thus, we conclude that FFcTi with melting sphere based multiporous structure has a hydrophilic, rough surface, and close modulus to bone. In vitro, its low proliferation and ALP activity promotion were similar to other micro scale roughed surface. In vivo test showed better osteogenesis ability when compared with MA at least in 2 weeks. Thus, this Farthing-Fray-Chen Titanium implant seems to hold considerable potential for bone implant applications. (c) 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 2395-2407, 2014.
引用
收藏
页码:2395 / 2407
页数:13
相关论文
共 50 条
  • [31] Analysis of the yield condition of porous bone-implant fixation
    Berdychowski, Maciej
    Mielniczuk, Janusz
    Matyjaszczyk, Miroslaw
    XXI POLISH-SLOVAK SCIENTIFIC CONFERENCE MACHINE MODELING AND SIMULATIONS MMS 2016, 2017, 177 : 358 - 362
  • [32] INGROWTH OF BONE IN A POROUS TITANIUM IMPLANT - QUANTITATIVE AND QUALITATIVE EVALUATION
    RONNINGEN, H
    SOLHEIM, LF
    LANGELAND, N
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1983, 43 : 47 - 47
  • [33] Significance of interstitial bone ingrowth under load-bearing conditions: A comparison between solid and porous implant materials
    Chang, YS
    Oka, M
    Kobayashi, M
    Gu, HO
    Li, ZL
    Nakamura, T
    Ikada, Y
    BIOMATERIALS, 1996, 17 (11) : 1141 - 1148
  • [34] Porous architected biomaterial for a tibial-knee implant with minimum bone resorption and bone-implant interface micromotion
    Rahimizadeh, Arnirmohammad
    Nourmohammadi, Zahra
    Arabnejad, Sajad
    Tanzer, Michael
    Pasini, Damiano
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 78 : 465 - 479
  • [35] Comparison of implant stability after different implant surface treatments in dog bone
    Kim, Sun-Jong
    Kim, Myung-Rae
    Rim, Jae-Suk
    Chung, Sung-Min
    Shin, Sang-Wan
    JOURNAL OF APPLIED ORAL SCIENCE, 2010, 18 (04) : 415 - 420
  • [36] Effect of implant surface roughness and loading on peri-implant bone formation
    Vandamme, Katleen
    Naert, Ignace
    Sloten, Jozef Vander
    Puers, Robert
    Duyck, Joke
    JOURNAL OF PERIODONTOLOGY, 2008, 79 (01) : 150 - 157
  • [37] Osteoblast maturation and new bone formation in response to titanium implant surface features are reduced with age
    Olivares-Navarrete, Rene
    Raines, Andrew L.
    Hyzy, Sharon L.
    Park, Jung Hwa
    Hutton, Daphne L.
    Cochran, David L.
    Boyan, Barbara D.
    Schwartz, Zvi
    JOURNAL OF BONE AND MINERAL RESEARCH, 2012, 27 (08) : 1773 - 1783
  • [38] Peri-Implant bone response around porous-surface dental implants: A preclinical meta-analysis
    Ahmed, Abeer
    Al-Rasheed, Abdulaziz
    Badwelan, Mohammed
    Alghamdi, Hamdan S.
    SAUDI DENTAL JOURNAL, 2021, 33 (05) : 239 - 247
  • [39] Implant surface roughness and bone healing: a systematic review
    Shalabi, M. M.
    Gortemaker, A.
    Van't Hof, M. A.
    Jansen, J. A.
    Creugers, N. H. J.
    JOURNAL OF DENTAL RESEARCH, 2006, 85 (06) : 496 - 500
  • [40] The Influence of implant geometry and surface composition on bone response
    Aldosari, Abdullah AlFarraj
    Anil, Sukumaran
    Alasqah, Mohammed
    Al Wazzan, Khalid A.
    Al Jetaily, Samer A.
    Jansen, John A.
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (04) : 500 - 505