Long-Term Detection of Living Cells by Dual-Charged Coupled Device Surface Plasmon Resonance Imaging

被引:0
|
作者
Dou, Fuyin [1 ]
Xing, Rui [2 ]
Wang, Peng [1 ]
Wang, Daqian [1 ]
Lu, Youyong [2 ]
Yu, Xinglong [1 ]
机构
[1] Tsinghua Univ, State Key Lab Precis Measurement Technol & Instr, Dept Precis Instruments, Beijing 100084, Peoples R China
[2] Peking Univ, Key Lab Carcinogenesis & Translat Res, Oncol Mol Lab, Sch Oncol,Beijing Canc Hosp & Inst,Minst Educ, Beijing 100142, Peoples R China
基金
中国国家自然科学基金;
关键词
Surface Plasmon Resonance; Flow Chamber; Detection of Living Cells; BGC-823; Cell; BIOSENSOR; MICROSCOPY;
D O I
10.1166/sl.2013.3025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Live cell detection using surface plasmon resonance (SPR) has recently attracted much attention. In this paper, real-time detection of living human cancer BGC-823 cells was achieved by a novel dual-CCD SPR imaging (SPRi) instrument in which a special flow chamber was designed and implemented. This flow chamber was able maintain suitable physiological conditions of living cells which permitted detection over long time scales. The proposed experiment outlined in this paper examined the effect of allicin on stimulation of cancer BGC-823 cells. Over the course of a 6 hour allicin exposure the total SPR signal response value was 1200 RU while cells not stimulated by allicin measured a response value of 2900 RU. This study demonstrates the ability of our SPRi system to detect the restrain effect of allicin on cancer cells in real time over several hours of data collection.
引用
收藏
页码:1875 / 1880
页数:6
相关论文
共 50 条
  • [31] Rhodamine bound maghemite as a long-term dual imaging nanoprobe of adipose tissue-derived mesenchymal stromal cells
    Vratislav Cmiel
    Josef Skopalik
    Katerina Polakova
    Jan Solar
    Marketa Havrdova
    David Milde
    Ivan Justan
    Massimiliano Magro
    Zenon Starcuk
    Ivo Provaznik
    European Biophysics Journal, 2017, 46 : 433 - 444
  • [32] Long-Term Detection of Oncogenic MicroRNA in Living Human Cancer Cells by Gold@ Polydopamine-Shell Nanoprobe
    Wong, Wai Ki
    Wong, Siu Hong Dexter
    Bian, Liming
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2020, 6 (07): : 3778 - 3783
  • [33] Long-term tracking of resovist-labeled mesenchymal stem cells in a swine heart by magnetic resonance imaging.
    Huang, Z. Y.
    Ge, I. B.
    Yang, S.
    Zhang, S. H.
    Huang, R. C.
    San, A. J.
    Qian, J. Y.
    Zou, Y. Z.
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (08): : 36F - 37F
  • [34] The long-term fate of mesenchymal stem cells labeled with magnetic resonance imaging-visible polymersomes in cerebral ischemia
    Duan, Xiaohui
    Lu, Liejing
    Wang, Yong
    Zhang, Fang
    Mao, Jiaji
    Cao, Minghui
    Lin, Bingling
    Zhang, Xiang
    Shuai, Xintao
    Shen, Jun
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 : 6705 - 6719
  • [35] Micro-cracks detection of solar cells surface via combining short-term and long-term deep features
    Qian, Xiaoliang
    Li, Jing
    Cao, Jinde
    Wu, Yuanyuan
    Wang, Wei
    NEURAL NETWORKS, 2020, 127 : 132 - 140
  • [36] Surface plasmon resonance imaging for ABH antigen detection on red blood cells and in saliva: secretor status-related ABO subgroup identification
    Peungthum, Patjaree
    Sudprasert, Krisda
    Amarit, Ratthasart
    Somboonkaew, Armote
    Sutapun, Boonsong
    Vongsakulyanon, Apirom
    Seedacoon, Wuttigrai
    Kitpoka, Pimpun
    Kunakorn, Mongkol
    Srikhirin, Toemsak
    ANALYST, 2017, 142 (09) : 1471 - 1481
  • [37] Long-term Embolic Outcomes After Detection of Left Ventricular Thrombus by Late Gadolinium Enhancement Cardiovascular Magnetic Resonance Imaging
    Choo, Christopher
    Kazmirczak, Felipe
    Farzaneh-Far, Afshin
    Misialek, Jeffrey R.
    Chen, Ko-Hsuan A.
    Markowitz, Jeremy
    Nijjar, Prabhjot S.
    Akcakaya, Mehmet
    Weinsaft, Jonathan W.
    Shenoy, Chetan
    CIRCULATION, 2017, 136
  • [38] A Novel Quantum Dot-Based pH Probe for Long-Term Fluorescence Lifetime Imaging Microscopy Experiments in Living Cells
    Herrera-Ochoa, Diego
    Pacheco-Linan, Pedro J.
    Bravo, Ivan
    Garzon-Ruiz, Andres
    ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (02) : 2578 - 2586
  • [39] Development of hypertension after long-term exposure to static magnetic fields among workers from a magnetic resonance imaging device manufacturing facility
    Bongers, Suzan
    Slottje, Pauline
    Kromhout, Hans
    ENVIRONMENTAL RESEARCH, 2018, 164 : 565 - 573
  • [40] Magnetic Resonance Imaging with Superparamagnetic Iron Oxide Fails to Track the Long-term Fate of Mesenchymal Stem Cells Transplanted into Heart
    Ning Ma
    Huaibing Cheng
    Minjie Lu
    Qiong Liu
    Xiuyu Chen
    Gang Yin
    Hao Zhu
    Lianfeng Zhang
    Xianmin Meng
    Yue Tang
    Shihua Zhao
    Scientific Reports, 5