Development and Applications of a Fundamental Parameter Method for X-ray Fluorescence Analysis

被引:2
|
作者
Kataoka, Yoshiyuki [1 ]
Kohno, Hisayuki [1 ]
Kawahara, Naoki [1 ]
Ochi, Hirotomo [2 ]
Nishino, Makoto [3 ]
Nakamura, Hideki [3 ]
机构
[1] Rigaku Corp, 14-8 Aka Cho, Takatsuki, Osaka 5691146, Japan
[2] Shimadzu Gen Serv, Res Ctr, Nakagyo Ku, 1 Nishinokyo Kuwabara Cho, Kyoto, Kyoto 6048511, Japan
[3] Shimadzu Co Ltd, Analyt & Measuring Instruments Div, Nakagyo Ku, 1 Nishinokyo Kuwabara Cho, Kyoto, Kyoto 6048511, Japan
关键词
X-ray fluorescence analysis; fundamental parameter method; Matrix correction; Scattering X-rays; standardless analysis; INTENSITIES;
D O I
10.2116/bunsekikagaku.69.363
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fundamental parameter (FP) method allows calculation of X-ray intensities theoretically and is used in various aspects of X-ray fluorescence (XRF) quantitative analysis. Wavelength dispersive X-ray fluorescence (WDXRF) spectrometers capable of performing the FP method were first developed in the late 1980s by Japanese manufacturers Rigaku and Shimadzu. Since then, through broadening of features including application to energy dispersive X-ray fluorescence (EDXRF) spectrometers and continuous improvements, it is now commonly used in various fields. The FP method is not only used for standardless analysis allowing quantification without type standards, but also for the analysis of coating and thin film thicknesses. It has also been adopted by JIS and ISO standard test methods of various materials as a method to calculate the matrix correction coefficients applied to the conventional calibration equation. FP method incorporating scattering X-ray intensities has also been developed for the analysis of polymers and biological samples and is also beneficial for the analysis of irregularly shaped samples. The authors recognize that the FP methods developed by the authors and their groups greatly contributed to the expansion of applications of X-ray fluorescence analysis.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 50 条
  • [41] X-ray tube spectral measurement method for quantitative analysis of X-ray fluorescence analysis
    Sasaki, Nobuharu
    Okada, Kennji
    Kawai, Jun
    X-RAY SPECTROMETRY, 2010, 39 (05) : 328 - 331
  • [42] Development of an X-ray fluorescence spectrometric method for the analysis of atmospheric aerosol samples
    Szilágyi, V
    Hartyáni, Z
    MICROCHEMICAL JOURNAL, 2005, 79 (1-2) : 37 - 41
  • [43] STUDIES ON FLUORESCENCE X-RAY ANALYSIS OF FERROALLOYS .2. BRIQUETTING METHOD OF FERROALLOYS FOR FLUORESCENCE X-RAY ANALYSIS
    OKUDA, K
    JAPAN ANALYST, 1971, 20 (06): : 717 - &
  • [44] DEVELOPMENT OF AN X-RAY FLUORESCENCE SPECTROMETER FOR ENVIRONMENTAL SCIENCE APPLICATIONS
    Espinosa, A. A.
    Reyes-Herrera, J.
    Miranda, J.
    Mercado, F.
    Veytia, M. A.
    Cuautle, M.
    Cruz, J. I.
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2012, 40 (06) : 603 - 617
  • [45] Fundamental Parameter Method for Energy Dispersive X-Ray Fluorescence and its Application to Stainless Steels as First Principles Calculation
    Tanaka, Ryohei
    Yamasaki, Keita
    Seki, Hiroko
    Matsumoto, Yuuki
    Kawai, Jun
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2019, 105 (10): : 981 - 987
  • [46] APPLICATION OF METHOD OF ADDITIONS IN X-RAY FLUORESCENCE ANALYSIS
    BRODKORB, E
    ZEITSCHRIFT FUR ANALYTISCHE CHEMIE FRESENIUS, 1969, 246 (05): : 289 - &
  • [47] Analysis of fresco paintings by X-ray fluorescence method
    Cechák, T
    Gerndt, J
    Musílek, L
    Kopecká, I
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 717 - 719
  • [48] APPLICATION OF FUNDAMENTAL PARAMETER METHOD FOR DETERMINATION OF MAJOR AND MINOR ELEMENTS ON FUSED GEOLOGICAL SAMPLES WITH X-RAY FLUORESCENCE SPECTROMETRY
    PALME, C
    JAGOUTZ, E
    ANALYTICAL CHEMISTRY, 1977, 49 (06) : 717 - 722
  • [49] X-RAY SPECTRAL-ANALYSIS OF MULTICOMPONENT SPECIMENS BY THE FUNDAMENTAL PARAMETER METHOD USED WITH EMPIRICAL FORMULAS
    KARMANOV, VI
    INDUSTRIAL LABORATORY, 1986, 52 (11): : 1006 - 1008
  • [50] X-ray fluorescence analysis by the fundamental parameters method without explicit knowledge of the excitation beam spectrum
    Martínez, VD
    Hidalgo, CM
    Barrea, RA
    X-RAY SPECTROMETRY, 2000, 29 (03) : 245 - 248