Development and Applications of a Fundamental Parameter Method for X-ray Fluorescence Analysis

被引:2
|
作者
Kataoka, Yoshiyuki [1 ]
Kohno, Hisayuki [1 ]
Kawahara, Naoki [1 ]
Ochi, Hirotomo [2 ]
Nishino, Makoto [3 ]
Nakamura, Hideki [3 ]
机构
[1] Rigaku Corp, 14-8 Aka Cho, Takatsuki, Osaka 5691146, Japan
[2] Shimadzu Gen Serv, Res Ctr, Nakagyo Ku, 1 Nishinokyo Kuwabara Cho, Kyoto, Kyoto 6048511, Japan
[3] Shimadzu Co Ltd, Analyt & Measuring Instruments Div, Nakagyo Ku, 1 Nishinokyo Kuwabara Cho, Kyoto, Kyoto 6048511, Japan
关键词
X-ray fluorescence analysis; fundamental parameter method; Matrix correction; Scattering X-rays; standardless analysis; INTENSITIES;
D O I
10.2116/bunsekikagaku.69.363
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fundamental parameter (FP) method allows calculation of X-ray intensities theoretically and is used in various aspects of X-ray fluorescence (XRF) quantitative analysis. Wavelength dispersive X-ray fluorescence (WDXRF) spectrometers capable of performing the FP method were first developed in the late 1980s by Japanese manufacturers Rigaku and Shimadzu. Since then, through broadening of features including application to energy dispersive X-ray fluorescence (EDXRF) spectrometers and continuous improvements, it is now commonly used in various fields. The FP method is not only used for standardless analysis allowing quantification without type standards, but also for the analysis of coating and thin film thicknesses. It has also been adopted by JIS and ISO standard test methods of various materials as a method to calculate the matrix correction coefficients applied to the conventional calibration equation. FP method incorporating scattering X-ray intensities has also been developed for the analysis of polymers and biological samples and is also beneficial for the analysis of irregularly shaped samples. The authors recognize that the FP methods developed by the authors and their groups greatly contributed to the expansion of applications of X-ray fluorescence analysis.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 50 条
  • [21] Application of fundamental parameter approach using integrated backscattering intensity for X-ray fluorescence analysis
    Hak-Son Jin
    Chol Ri
    Yon-Song Jong
    Applied Physics A, 2020, 126
  • [22] X-RAY-FLUORESCENCE ANALYSIS OF TITANIUM-ALLOYS USING THE FUNDAMENTAL PARAMETER METHOD
    ITOH, S
    SATO, K
    TAKAHASHI, J
    OKOCHI, H
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 1988, 52 (08) : 797 - 802
  • [23] Solution of inverse problem of therman equation in quantitative X-ray fluorescence analysis - Theoretical effect coefficint method and fundamental parameter method
    Tan, BH
    Wang, GH
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2000, 20 (03) : 399 - 401
  • [24] Total Quantification of Magnesium Alloys by X-ray Fluorescence Spectrometry Using the “Standardless” Fundamental Parameter Method
    Wataru Matsuda
    Atsushi Morikawa
    Atsushi Ohbuchi
    Takao Moriyama
    Toshihiro Nakamura
    Analytical Sciences, 2020, 36 : 1065 - 1070
  • [25] X-ray fluorescent analysis of beta titanium alloys using the fundamental parameter method
    Mori, S
    Akasaki, K
    Matsumoto, Y
    BUNSEKI KAGAKU, 1996, 45 (09) : 887 - 893
  • [26] Total Quantification of Magnesium Alloys by X-ray Fluorescence Spectrometry Using the "Standardless" Fundamental Parameter Method
    Matsuda, Wataru
    Morikawa, Atsushi
    Ohbuchi, Atsushi
    Moriyama, Takao
    Nakamura, Toshihiro
    ANALYTICAL SCIENCES, 2020, 36 (09) : 1065 - 1070
  • [27] Characterization of electronic materials using fundamental parameter micro X-ray fluorescence
    Wong, Connor
    2014 IEEE 36TH INTERNATIONAL ELECTRONICS MANUFACTURING TECHNOLOGY CONFERENCE (IEMT), 2015,
  • [28] Fundamental characteristics of hybrid X-ray focusing optics for micro X-ray fluorescence analysis
    Komatani, Shintaro
    Nakamachi, Kazuo
    Nakano, Kazuhiko
    Ohzawa, Sumito
    Uchihara, Hiroshi
    Bando, Atsushi
    Tsuji, Kouichi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 309 : 260 - 263
  • [29] Application of selected fundamental parameters in x-ray fluorescence analysis
    Zhuo, SJ
    Tao, GY
    Ji, A
    X-RAY SPECTROMETRY, 2003, 32 (01) : 8 - 12
  • [30] Preparation of sample solutions using nanoimprint films for quantitative X-ray fluorescence analysis by thin film fundamental parameter method
    Konyuba, Y.
    Onodera, H.
    Yahagi, T.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 177