Experimental study on the effect of exhaust airflows on the surgical environment in an operating room with mixing ventilation

被引:20
|
作者
Xue, Kai [1 ,2 ,4 ]
Cao, Guangyu [2 ]
Liu, Meng [1 ,4 ]
Zhang, Yixian [1 ,2 ]
Pedersen, Christoffer [2 ]
Mathisen, Hans Martin [2 ]
Stenstad, Liv-Inger [3 ]
Skogas, Jan Gunnar [3 ]
机构
[1] Chongqing Univ, Chongqing, Peoples R China
[2] Norwegian Univ Sci & Technol NTNU, Trondheim, Norway
[3] St Olavs Hosp, Operating Room Future, Trondheim, Norway
[4] Chongqing Univ, Minist Sci & Technol, Natl Ctr Int Res Low Carbon & Green Bldg, Chongqing, Peoples R China
来源
关键词
Exhaust airflow; Mixing ventilation; Operating rooms; Bacteria-carrying particles; THERMAL COMFORT; INFECTION; REMOVAL; PERFORMANCE; SYSTEM; IMPACT;
D O I
10.1016/j.jobe.2020.101837
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to the requirements of indoor environment parameters, including temperature, humidity, air speed and indoor quality, the design of the surgical environment is a very complex task. However, with limited studies on the effective exhaust airflow in the operating room (OR), the impact of exhaust airflow on the surgical environment is still unclear, especially when mixing ventilation with multiple supply and multiple exhaust. The objective of this study was to identify the effect of different exhaust airflow on the air quality in the surgical environment of a full-scaled OR laboratory with mixing ventilation. Experimental measurements were performed with three scenarios of ventilation solutions at two different air change rates. The air velocity, turbulence intensity, air temperature, and tracer gas concentration were measured to evaluate the indoor quality of the surgical environment. The results suggested that a better layout for the instrument table should be placed at 1.0-1.5 m from the wall. Furthermore, airflow from the inlet to the outlet should be guaranteed to cross the clean zone as much as possible, and no obstacles should be placed in the path of the airflow from the inlet to the outlet. The results also indicated that airflow with six exhausts were best, with a higher contaminant removal efficiency of about 38% than eight exhausts in 18 g(-1) ACH, while for 20 h(-1), a four-exhaust strategy was the best at approximately 35% higher than eight exhausts. The results of this study may contribute to more effective ventilation systems for OR.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Surgical site infection (SSI) outbreak linked to faulty operating room (OR) ventilation.
    Engel, JP
    McLay, C
    Sasser, E
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1998, 19 (09): : 709 - 709
  • [42] Better Operating Room Ventilation as Determined by a Novel Ventilation Index is Associated With Lower Rates of Surgical Site Infections
    Surial, Bernard
    Atkinson, Andrew
    Kulpmann, Rudiger
    Brunner, Arnold
    Hildebrand, Kurt
    Sicre, Benoit
    Troillet, Nicolas
    Widmer, Andreas
    Rolli, Eveline
    Maag, Judith
    Marschall, Jonas
    [J]. ANNALS OF SURGERY, 2022, 276 (05) : E353 - E360
  • [43] Influence of two different operating room ventilation systems on the surgical smoke exposure of surgeons
    Seipp, Hans-Martin
    Wild, Michael
    Sticher, Jochen
    Maier-Hasselmann, Andreas
    Esters, Jan
    Steffens, Thomas
    Birnstein, Katja
    Ziegler, Mareike
    Herzog-Niescery, Jennifer
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 52
  • [44] A quantitative cross-sectional study assessing the surgical trainee perception of the operating room educational environment
    Neal Rupani
    Ashish Evans
    Mohammad Iqbal
    [J]. BMC Medical Education, 22
  • [45] A quantitative cross-sectional study assessing the surgical trainee perception of the operating room educational environment
    Rupani, Neal
    Evans, Ashish
    Iqbal, Mohammad
    [J]. BMC MEDICAL EDUCATION, 2022, 22 (01)
  • [46] Operating Room Ventilation With Laminar Airflow Shows No Protective Effect on the Surgical Site Infection Rate in Orthopedic and Abdominal Surgery
    Brandt, Christian
    Hott, Uwe
    Sohr, Dorit
    Daschner, Franz
    Gastmeier, Petra
    Rueden, Henning
    [J]. ANNALS OF SURGERY, 2008, 248 (05) : 695 - 700
  • [47] Protective Effect of HEPA-Filtered Operating Room Air Ventilation With or Without Laminar Airflow on Surgical Site Infections
    Assadian, Ojan
    Kuelpmann, Ruediger
    Zhumadilova, Anara
    Kobayashi, Hiroyoshi
    Heidecke, Claus-Dieter
    Kramer, Axel
    [J]. ANNALS OF SURGERY, 2009, 250 (04) : 659 - 660
  • [48] Experimental and CFD study of exhaust ejectors with bent mixing tubes
    Maqsood, Asim
    Birk, A. M.
    [J]. Proceedings of the ASME Turbo Expo 2005, Vol 1, 2005, : 155 - 165
  • [49] The effect of type of ventilation used in the operating room and surgical site infection: A meta-analysis (Publication with Expression of Concern)
    Bao, Jian
    Li, Jianhua
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2021, 42 (08): : 931 - 936
  • [50] Experimental study on air change effectiveness in mixing ventilation
    Amai, Hideyuki
    Novoselac, Atila
    [J]. BUILDING AND ENVIRONMENT, 2016, 109 : 101 - 111