Experimental study on the effect of exhaust airflows on the surgical environment in an operating room with mixing ventilation

被引:20
|
作者
Xue, Kai [1 ,2 ,4 ]
Cao, Guangyu [2 ]
Liu, Meng [1 ,4 ]
Zhang, Yixian [1 ,2 ]
Pedersen, Christoffer [2 ]
Mathisen, Hans Martin [2 ]
Stenstad, Liv-Inger [3 ]
Skogas, Jan Gunnar [3 ]
机构
[1] Chongqing Univ, Chongqing, Peoples R China
[2] Norwegian Univ Sci & Technol NTNU, Trondheim, Norway
[3] St Olavs Hosp, Operating Room Future, Trondheim, Norway
[4] Chongqing Univ, Minist Sci & Technol, Natl Ctr Int Res Low Carbon & Green Bldg, Chongqing, Peoples R China
来源
关键词
Exhaust airflow; Mixing ventilation; Operating rooms; Bacteria-carrying particles; THERMAL COMFORT; INFECTION; REMOVAL; PERFORMANCE; SYSTEM; IMPACT;
D O I
10.1016/j.jobe.2020.101837
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to the requirements of indoor environment parameters, including temperature, humidity, air speed and indoor quality, the design of the surgical environment is a very complex task. However, with limited studies on the effective exhaust airflow in the operating room (OR), the impact of exhaust airflow on the surgical environment is still unclear, especially when mixing ventilation with multiple supply and multiple exhaust. The objective of this study was to identify the effect of different exhaust airflow on the air quality in the surgical environment of a full-scaled OR laboratory with mixing ventilation. Experimental measurements were performed with three scenarios of ventilation solutions at two different air change rates. The air velocity, turbulence intensity, air temperature, and tracer gas concentration were measured to evaluate the indoor quality of the surgical environment. The results suggested that a better layout for the instrument table should be placed at 1.0-1.5 m from the wall. Furthermore, airflow from the inlet to the outlet should be guaranteed to cross the clean zone as much as possible, and no obstacles should be placed in the path of the airflow from the inlet to the outlet. The results also indicated that airflow with six exhausts were best, with a higher contaminant removal efficiency of about 38% than eight exhausts in 18 g(-1) ACH, while for 20 h(-1), a four-exhaust strategy was the best at approximately 35% higher than eight exhausts. The results of this study may contribute to more effective ventilation systems for OR.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Numerical and Experimental Study of the Ventilation in an Operating Hydrogenerator
    Torriano, F.
    Stella, S.
    Jayet, Y.
    Ardaillon, T.
    Charest-Fournier, J-P
    Hudon, C.
    Merkhouf, A.
    Guillot, E.
    [J]. INTERNATIONAL CONFERENCE ON NUMERICAL ANALYSIS AND APPLIED MATHEMATICS (ICNAAM-2018), 2019, 2116
  • [32] Impact of surgical lamp design on the risk of surgical site infections in operating rooms with mixing and unidirectional airflow ventilation: A numerical study
    Sadeghian, Parastoo
    Wang, Cong
    Duwig, Christophe
    Sadrizadeh, Sasan
    [J]. JOURNAL OF BUILDING ENGINEERING, 2020, 31
  • [33] OPERATING-ROOM VENTILATION IN DAILY ROUTINE - A PRACTICAL STUDY
    BISCHOFF, WE
    SANDER, U
    SANDER, J
    [J]. ZENTRALBLATT FUR HYGIENE UND UMWELTMEDIZIN, 1994, 195 (04): : 306 - 318
  • [34] An experimental study on ventilation efficiency of isolation room
    Tung, Yun-Chun
    Hu, Shih-Cheng
    Tsai, Tung-I
    Chang, I-Lang
    [J]. BUILDING AND ENVIRONMENT, 2009, 44 (02) : 271 - 279
  • [35] Measuring Surgical Trainee Perceptions to Assess the Operating Room Educational Environment
    Diwadkar, Gouri B.
    Jelovsek, J. Eric
    [J]. JOURNAL OF SURGICAL EDUCATION, 2010, 67 (04) : 210 - 216
  • [36] OPERATING-ROOM ENVIRONMENT AS AFFECTED BY PEOPLE AND SURGICAL FACE MASK
    RITTER, MA
    EITZEN, H
    FRENCH, MLV
    HART, JB
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1975, (111) : 147 - 150
  • [37] Gynaecological surgical training in the operating room: an exploratory study
    van der Houwen, Clasien
    Boor, Klarke
    Essed, Gerard G. M.
    Boendermaker, Peter M.
    Scherpbier, Albert A. J. J. A.
    Scheele, Fedde
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2011, 154 (01) : 90 - 95
  • [38] Experimental analysis of airborne contaminant distribution in an operating room with different ventilation schemes
    Schumann, Lukas
    Lange, Julia
    Cetin, Yunus Emre
    Kriegel, Martin
    [J]. BUILDING AND ENVIRONMENT, 2023, 244
  • [39] The operating room as a clinical learning environment: An exploratory study
    Meyer, Rhoda
    Van Schalkwyk, Susan C.
    Prakaschandra, Rosaley
    [J]. NURSE EDUCATION IN PRACTICE, 2016, 18 : 60 - 72
  • [40] Experimental Study on Influence of Overhang of Exhaust Hood on Ventilation Requirements
    Iwamatsu, Toshiya
    Urabe, Wataru
    [J]. 2017 ASHRAE ANNUAL CONFERENCE PAPERS, 2017,