Loop-Mediated Isothermal Amplification as Point-of-Care Diagnosis for Neglected Parasitic Infections

被引:29
|
作者
Avendano, Catalina [1 ]
Alfonso Patarroyo, Manuel [2 ,3 ]
机构
[1] Univ Ciencias Aplicadas & Ambientales UDCA, Anim Sci Fac, Bogota 111166, Colombia
[2] Fdn Inst Inmunol Colombia FIDIC, Mol Biol & Immunol Dept, Bogota 111321, Colombia
[3] Univ Rosario, Sch Med & Hlth Sci, Basic Sci Dept, Bogota 112111, Colombia
关键词
neglected parasitic infection; diagnostic test; LAMP; sensitivity; HUMAN AFRICAN TRYPANOSOMIASIS; NUCLEIC-ACID AMPLIFICATION; RAPID DETECTION; LAMP ASSAY; SAND FLIES; CUTANEOUS LEISHMANIASIS; VISCERAL LEISHMANIASIS; CLONORCHIS-SINENSIS; SCHISTOSOMA-MANSONI; SENSITIVE DETECTION;
D O I
10.3390/ijms21217981
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The World Health Organisation (WHO) has placed twenty diseases into a group known as neglected tropical diseases (NTDs), twelve of them being parasitic diseases: Chagas' disease, cysticercosis/taeniasis, echinococcosis, food-borne trematodiasis, human African trypanosomiasis (sleeping sickness), leishmaniasis, lymphatic filariasis, onchocerciasis (river blindness), schistosomiasis, soil-transmitted helminthiasis (ascariasis, hookworm, trichuriasis), guinea-worm and scabies. Such diseases affect millions of people in developing countries where one of the main problems concerning the control of these diseases is diagnosis-based due to the most affected areas usually being far from laboratories having suitable infrastructure and/or being equipped with sophisticated equipment. Advances have been made during the last two decades regarding standardising and introducing techniques enabling diagnoses to be made in remote places, i.e., the loop-mediated isothermal amplification (LAMP) technique. This technique's advantages include being able to perform it using simple equipment, diagnosis made directly in the field, low cost of each test and the technique's high specificity. Using this technique could thus contribute toward neglected parasite infection (NPI) control and eradication programmes. This review describes the advances made to date regarding LAMP tests, as it has been found that even though several studies have been conducted concerning most NPI, information is scarce for others.
引用
收藏
页码:1 / 32
页数:32
相关论文
共 50 条
  • [41] Diagnosis of Ruminant Viral Diseases with Loop-Mediated Isothermal Amplification
    Kok, Sanem Ayaz
    Ustun, Selcen
    Sezgin, Humeyra Taskent
    MOLECULAR BIOTECHNOLOGY, 2023, 65 (08) : 1228 - 1241
  • [42] A loop-mediated isothermal amplification assay for the diagnosis of pulmonary tuberculosis
    Sharma, G.
    Tewari, R.
    Dhatwalia, S. K.
    Yadav, R.
    Behera, D.
    Sethi, S.
    LETTERS IN APPLIED MICROBIOLOGY, 2019, 68 (03) : 219 - 225
  • [43] MALARIA DIAGNOSIS BY LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) IN THAILAND
    Ocker, Ronja
    Prompunjai, Yongyut
    Chutipongvivate, Salakchit
    Karanis, Panagiotis
    REVISTA DO INSTITUTO DE MEDICINA TROPICAL DE SAO PAULO, 2016, 58
  • [44] Loop-Mediated Isothermal Amplification in Schistosomiasis
    Garcia-Bernalt Diego, Juan
    Fernandez-Soto, Pedro
    Febrer-Sendra, Begona
    Crego-Vicente, Beatriz
    Muro, Antonio
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (03) : 1 - 13
  • [45] Loop-Mediated Isothermal Amplification for the Diagnosis of Sporotrichosis by Sporothrix brasiliensis
    Araujo, Marcella Donadel
    Poester, Vanice Rodrigues
    Schirmer, Helena
    Mattevi, Vanessa Sune
    Trapaga, Mariana Rodrigues
    Xavier, Melissa Orzechowski
    Teixeira, Marcus de Melo
    Almeida-Paes, Rodrigo
    Zancope-Oliveira, Rosely Maria
    Severo, Cecilia Bittencourt
    MYCOPATHOLOGIA, 2024, 189 (05)
  • [46] Loop-Mediated Isothermal Amplification for Rapid Diagnosis of Tubercular Uveitis
    Balne, Praveen Kumar
    Basu, Soumyava
    Sharma, Savitri
    JAMA OPHTHALMOLOGY, 2015, 133 (02) : 225 - 226
  • [47] Loop-Mediated Isothermal Amplification for Rapid Diagnosis of Tubercular Uveitis
    Sharma, Kusum
    Bansal, Reema
    Sharma, Aman
    Beke, Nikhil
    Gupta, Amod
    JAMA OPHTHALMOLOGY, 2014, 132 (06) : 777 - 778
  • [48] Loop-mediated isothermal amplification test for the molecular diagnosis of malaria
    Han, Eun-Taek
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2013, 13 (02) : 205 - 218
  • [49] Loop-mediated isothermal amplification of DNA
    Notomi, Tsugunori
    Okayama, Hiroto
    Masubuchi, Harumi
    Yonekawa, Toshihiro
    Watanabe, Keiko
    Amino, Nobuyuki
    Hase, Tetsu
    NUCLEIC ACIDS RESEARCH, 2000, 28 (12)
  • [50] The loop-mediated isothermal amplification assay for rapid diagnosis of Babesia canis canis infections in dogs
    Adaszek, L.
    Jankowska, M.
    Kalinowski, M.
    Banach, T.
    Wulupek, D.
    Winiarczyk, S.
    POLISH JOURNAL OF VETERINARY SCIENCES, 2013, 16 (01): : 131 - 133