Experimental study on the start-up with dry gases from normal cell temperatures in self-humidified proton exchange membrane fuel cells

被引:18
|
作者
Kong, Im Mo [1 ]
Jung, Aeri [2 ]
Kim, Beom Jun [3 ]
Baik, Kyung Don [4 ]
Kim, Min Soo [2 ]
机构
[1] Seoul Natl Univ, Plus Transformat Training Program Creat Mec & Aer, Seoul 151744, South Korea
[2] Seoul Natl Univ, Dept Mech & Aerosp Engn, Seoul 151744, South Korea
[3] Korea Inst Energy Res, Hydrogen & Fuel Cell Ctr Ind Acad & Labs, Buan Gun, Jeollabuk Do, South Korea
[4] Agcy Def Dev, Daejeon 305152, South Korea
基金
新加坡国家研究基金会;
关键词
Proton exchange membrane fuel cell; Start-up; Dry gas; Reactant flow arrangement; Water storage process; Hydrogen crossover; HYDROGEN CROSSOVER RATE; COLD-START; ELECTRODE ASSEMBLIES; OPERATING-CONDITIONS; WATER; PARAMETERS; BEHAVIOR; SUBZERO; PERFORMANCE; RANGE;
D O I
10.1016/j.energy.2015.09.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the start-up characteristics of PEMFCs (proton exchange membrane fuel cells) was investigated with dry gases from normal cell temperatures above 0 degrees C. Firstly, the effects of flow arrangements (co-flow and counter-flow) were evaluated at a starting cell temperature of 25 degrees C. Then, the start-up was successful in both arrangements, but it showed better performance with counter-flow. In addition, the hydrogen concentration was measured and it showed that hydrogen crossover contributes to the membrane hydration and the first phase of dry start-up. However, although the cell temperature rose above 45 degrees C after start-up form 25 degrees C with counter-flow arrangement, the restart-up after shut-down failed at a starting cell temperature of 45 degrees C regardless of flow arrangements. Considering the needs of restart-up, the available starting cell temperature should be improved. For this, after first sub-step of start-up process, relatively low flow rates were maintained to retain produced water without purge so that the membrane can be hydrated sufficiently. With this modified process, denominated as WSP (water storage process) in this study, the dry start-up became successful at a starting cell temperature of 45 degrees C and the cell performance was remarkably improved especially with counter-flow arrangement. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:57 / 66
页数:10
相关论文
共 50 条
  • [41] Cathode catalyst layer aging of proton exchange membrane fuel cell during emulated start-up/shut-down phases
    Drugeot, Timothee
    Wane, Raky
    Micoud, Fabrice
    Pinton, Eric
    Guetaz, Laure
    Mermoux, Michel
    Bultel, Yann
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 87 : 838 - 847
  • [42] A focused review of carbon corrosion mechanism in proton exchange membrane fuel cell during start-up and shut-down processes
    Mansir, Ibrahim B.
    Okonkwo, Paul C.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (02) : 3231 - 3245
  • [43] Experimental investigation on dynamic characteristics of proton exchange membrane fuel cells at subzero temperatures
    Jia, Li
    Tan, Zetao
    Kang, Mi
    Zhang, Zhuqian
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (21) : 11120 - 11127
  • [44] Experimental study on shutdown strategy of proton exchange membrane fuel cells
    Wang Y.
    Liu Z.-X.
    Liu, Zhi-Xiang (liuzhxiang@swjtu.edu.cn), 1600, Zhejiang University (30): : 1197 - 1202
  • [45] Mathematical modeling and experimental study of proton exchange membrane fuel cells
    Grigoriev, SA
    Kalinnikov, AA
    Porembsky, VI
    Fateev, VN
    Fuel Cell Technologies: State and Perspectives, 2005, 202 : 205 - 210
  • [46] Experimental Study of Proton Exchange Membrane Fuel Cell Purge with Load
    Zhu J.
    Liu C.
    Liu J.
    Xu S.
    Tongji Daxue Xuebao/Journal of Tongji University, 2021, 49 : 254 - 259
  • [47] Alternate Hydrogen Pump Method Enables Start-Up from-30°C for Graphite-Bipolar-Plate Proton Exchange Membrane Fuel Cells
    Wen, Junning
    Si, Dechun
    Wang, Shangshang
    Ding, Han
    Li, Chaoming
    Ono, Kei
    Chen, Zhili
    Zhang, Jianbo
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (14) : F1112 - F1116
  • [48] Numerical analysis of high-temperature proton exchange membrane fuel cells during start-up by inlet gas heating and applied voltage
    Rasheed, Raj Kamal Abdul
    Zhang, Caizhi
    Chan, Siew Hwa
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (15) : 10390 - 10406
  • [49] 3D non-isothermal dynamic simulation of high temperature proton exchange membrane fuel cell in the start-up process
    Zhang, Jun
    Zhang, Caizhi
    Hao, Dong
    Ni, Meng
    Huang, Shulong
    Liu, Deman
    Zheng, Yifeng
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (02) : 2577 - 2593
  • [50] Investigation on the temperature uniformity and efficiency of cold start-up for proton exchange membrane fuel cell stack based on catalytic hydrogen/oxygen method
    Sun, Jiaqi
    Yang, Xiaokang
    Sun, Shucheng
    Shao, Zhigang
    JOURNAL OF POWER SOURCES, 2021, 496