Experimental study on the start-up with dry gases from normal cell temperatures in self-humidified proton exchange membrane fuel cells

被引:18
|
作者
Kong, Im Mo [1 ]
Jung, Aeri [2 ]
Kim, Beom Jun [3 ]
Baik, Kyung Don [4 ]
Kim, Min Soo [2 ]
机构
[1] Seoul Natl Univ, Plus Transformat Training Program Creat Mec & Aer, Seoul 151744, South Korea
[2] Seoul Natl Univ, Dept Mech & Aerosp Engn, Seoul 151744, South Korea
[3] Korea Inst Energy Res, Hydrogen & Fuel Cell Ctr Ind Acad & Labs, Buan Gun, Jeollabuk Do, South Korea
[4] Agcy Def Dev, Daejeon 305152, South Korea
基金
新加坡国家研究基金会;
关键词
Proton exchange membrane fuel cell; Start-up; Dry gas; Reactant flow arrangement; Water storage process; Hydrogen crossover; HYDROGEN CROSSOVER RATE; COLD-START; ELECTRODE ASSEMBLIES; OPERATING-CONDITIONS; WATER; PARAMETERS; BEHAVIOR; SUBZERO; PERFORMANCE; RANGE;
D O I
10.1016/j.energy.2015.09.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the start-up characteristics of PEMFCs (proton exchange membrane fuel cells) was investigated with dry gases from normal cell temperatures above 0 degrees C. Firstly, the effects of flow arrangements (co-flow and counter-flow) were evaluated at a starting cell temperature of 25 degrees C. Then, the start-up was successful in both arrangements, but it showed better performance with counter-flow. In addition, the hydrogen concentration was measured and it showed that hydrogen crossover contributes to the membrane hydration and the first phase of dry start-up. However, although the cell temperature rose above 45 degrees C after start-up form 25 degrees C with counter-flow arrangement, the restart-up after shut-down failed at a starting cell temperature of 45 degrees C regardless of flow arrangements. Considering the needs of restart-up, the available starting cell temperature should be improved. For this, after first sub-step of start-up process, relatively low flow rates were maintained to retain produced water without purge so that the membrane can be hydrated sufficiently. With this modified process, denominated as WSP (water storage process) in this study, the dry start-up became successful at a starting cell temperature of 45 degrees C and the cell performance was remarkably improved especially with counter-flow arrangement. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:57 / 66
页数:10
相关论文
共 50 条
  • [31] TRANSIENT COMPUTATIONAL ANALYSIS OF PROTON EXCHANGE MEMBRANE FUEL CELLS DURING LOAD CHANGE AND NON-ISOTHERMAL START-UP
    Roy, Arnab
    Serincan, Mustafa Fazil
    Pasaogullari, Ugur
    Renfro, Michael W.
    Cetegen, Baki M.
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY, 2009, : 429 - 438
  • [32] Start-up characteristics of high-temperature proton exchange membrane fuel cell stacks based on flat heat pipes
    Qian Z.
    Wang S.
    Zhu Y.
    Yue L.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2024, 43 (04): : 1754 - 1763
  • [33] An Experimental Study on Micro Proton Exchange Membrane Fuel Cell
    Chen, Chiun-Hsun
    Chen, Tang-Yuan
    Cheng, Chih-Wei
    Peng, Rong-Guie
    JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2012, 9 (03):
  • [34] An experimental study on the performance of proton exchange membrane fuel cell
    Kellegoz, M.
    Ozkan, I.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2016, 18 (3-4): : 399 - 406
  • [35] Experimental investigation of the performance of a single proton exchange membrane fuel cell using dry fuel
    Su, A
    Sun, CC
    Weng, FB
    Chen, YM
    EXPERIMENTAL HEAT TRANSFER, 2003, 16 (02) : 97 - 109
  • [36] Comparison of self cold start strategies of automotive Proton Exchange Membrane Fuel Cell
    Amamou, A.
    Boulon, L.
    Kelouwani, S.
    2018 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2018, : 904 - 908
  • [37] Experimental study of the start-up of a fuel cell stack for backup power application
    Didierjean, Sophie
    Chenu, Alain
    Geneston, Thierry
    Rakotondrainibe, Andre
    Maranzana, Gael
    Rozier, Erik
    Beille, Florent
    Lottin, Olivier
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (11) : 9193 - 9201
  • [38] Study on the temperature distribution and its effect on self-start of large-area proton exchange membrane fuel cells at subzero temperatures
    Yang, Xiaokang
    Sun, Jiaqi
    Sun, Shucheng
    Yu, Hongmei
    Shao, Zhigang
    ELECTROCHIMICA ACTA, 2021, 396
  • [39] Experimental investigation on scaling and stacking up of proton exchange membrane fuel cells
    Karthikeyan, P.
    Velmurugan, P.
    George, Abby Joseph
    Kumar, R. Ram
    Vasanth, R. J.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (21) : 11186 - 11195
  • [40] Selective anode catalyst for the mitigation of start-up/shut-down induced cathode degradation in proton exchange membrane fuel cells
    Stuehmeier, Bjoern M.
    Damjanovic, Ana Marija
    Rodewald, Katia
    Gasteiger, Hubert A.
    JOURNAL OF POWER SOURCES, 2023, 558