The effect of chart speed on fetal monitor interpretation

被引:5
|
作者
Peleg, David [1 ]
Ram, Reut [1 ]
Warsof, Steven L. [2 ]
Wolf, Maya Frank [1 ]
Larion, Sebastian [2 ]
Beydoun, Hind A. [3 ]
Trochakerian, Sarine [2 ]
Shachar, Inbar Ben [1 ]
机构
[1] Bar Ilan Univ, Ziv Med Ctr, Fac Med, Dept Obstet & Gynecol, Galilee, Israel
[2] Eastern Virginia Med Sch, Div Maternal Fetal Med, Norfolk, VA 23501 USA
[3] Eastern Virginia Med Sch, Grad Program Publ Hlth, Norfolk, VA 23501 USA
来源
关键词
intrapartum fetal assessment; Fetal assessment; fetal heart rate; fetal heart monitor chart speed;
D O I
10.3109/14767058.2015.1054804
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Electronic fetal heart monitor chart speeds vary between countries, and it is unclear whether differing chart speeds affect physician tracing interpretation. Methods: Twenty-minute segments of 19 tracings were displayed on both 1 and 3 cm/min strips and interpreted by 14 physicians at the particular speed they were accustomed to reading. Interpretations of tracing characteristics were compared between groups using free margin kappa, a measure of interobserver agreement. Results: Compared to 3 cm/min tracings, 1 cm/min tracings were significantly more often identified as having absent than minimal variability, and minimal than moderate variability. Accelerations were significantly more often identified in 1 versus 3 cm/min strips. There were no significant differences between groups with respect to baseline fetal heart rate, prolonged or repetitive decelerations, or American College of Obstetricians and Gynecologists tracing category. Neither chart speed had substantial interobserver agreement in tracing variables; however, agreement was consistently higher in 3 versus 1 cm/min tracings (all p < 0.05). Conclusions: Tracing interpretation is significantly affected by fetal monitor chart speed with regards to variability, acceleration and deceleration. Further studies are required to determine if differences in chart speed interpretation affect clinical management.
引用
收藏
页码:1577 / 1580
页数:4
相关论文
共 50 条
  • [41] Using average control chart with subgroups to monitor turnaround time
    Kao, Shih-Chou
    [J]. JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2012, 71 (01): : 27 - 35
  • [42] A Semi-empirical Bayesian Chart to Monitor Weibull Percentiles
    Erto, Pasquale
    Pallotta, Giuliana
    Mastrangelo, Christina M.
    [J]. SCANDINAVIAN JOURNAL OF STATISTICS, 2015, 42 (03) : 701 - 712
  • [43] Using Runs Rules to Monitor an Attribute Chart for a Markov Process
    Shepherd, Deborah K.
    Rigdon, Steven E.
    Champ, Charles W.
    [J]. QUALITY TECHNOLOGY AND QUANTITATIVE MANAGEMENT, 2012, 9 (04): : 383 - 406
  • [44] MODIFYING THE FETAL MONITOR MAY BE HAZARDOUS
    SAND, DB
    [J]. ANESTHESIOLOGY, 1987, 67 (03) : 448 - 449
  • [45] Revisiting the use of the electronic fetal monitor
    Thacker, SB
    Stroup, DF
    [J]. LANCET, 2003, 361 (9356): : 445 - 446
  • [46] BMT 9141 - NEW FETAL MONITOR
    HOFMANN, P
    HARTING, T
    SCHARNER, W
    NAGEL, H
    [J]. ZENTRALBLATT FUR GYNAKOLOGIE, 1981, 103 (18): : 1081 - 1088
  • [47] A PRACTICAL FETAL-HEART MONITOR
    BRUSER, M
    [J]. OBSTETRICS AND GYNECOLOGY, 1967, 29 (04): : 551 - &
  • [48] The use of a CUSUM residual chart to monitor respiratory syndromic data
    Chen, Huifen
    Huang, Chaosian
    [J]. IIE TRANSACTIONS, 2014, 46 (08) : 790 - 797
  • [49] MaxD: an attribute control chart to monitor a bivariate process mean
    M. S. Melo
    L. L. Ho
    P. G. Medeiros
    [J]. The International Journal of Advanced Manufacturing Technology, 2017, 90 : 489 - 498
  • [50] A transformation-based multivariate chart to monitor process dispersion
    Abbasi, B.
    Niaki, S. T. A.
    Abdollahian, M.
    Hosseinifard, S. Z.
    [J]. INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2009, 44 (7-8): : 748 - 756